    textabstractNegative pressure wound therapy is a concept introduced initially to assist in the treatment of chronic open wounds. Recently, there has been growing interest in using the technique on closed incisions after surgery to prevent potentially severe surgical site infections and other wound complications in high-risk patients. Negative pressure wound therapy uses a negative pressure unit and specific dressings that help to hold the incision edges together, redistribute lateral tension, reduce edema, stimulate perfusion, and protect the surgical site from external infectious sources. Randomized, controlled studies of negative pressure wound therapy for closed incisions in orthopedic settings (which also is a clean surgical procedure in absence of an open fracture) have shown the technology can reduce the risk of wound infection, wound dehiscence, and seroma, and there is accumulating evidence that it also improves wound outcomes after cardiothoracic surgery. Identifying at-risk individuals for whom prophylactic use of negative pressure wound therapy would be most cost-effective remains a challenge; however, several risk-stratification systems have been proposed and should be evaluated more fully. The recent availability of a single-use, closed incision management system offers surgeons a convenient and practical means of delivering negative pressure wound therapy to their high-risk patients, with excellent wound outcomes reported to date. Although larger, randomized, controlled studies will help to clarify the precise role and benefits of such a system in cardiothoracic surgery, limited initial evidence from clinical studies and from the authors’ own experiences appears promising. In light of the growing interest in this technology among cardiothoracic surgeons, a consensus meeting, which was attended by a group of international experts, was held to review existing evidence for negative pressure wound therapy in the prevention of wound complications after surgery and to provide recommendations on the optimal use of negative pressure wound therapy on closed median sternal incisions after cardiothoracic surgery

    A rigid barrier between the heart and sternum protects the heart and lungs against rupture during negative pressure wound therapy

    Get PDF
    <p>Abstract</p> <p>Objectives</p> <p>Right ventricular heart rupture is a devastating complication associated with negative pressure wound therapy (NPWT) in cardiac surgery. The use of a rigid barrier has been suggested to offer protection against this lethal complication, by preventing the heart from being drawn up and damaged by the sharp edges of the sternum. The aim of the present study was to investigate whether a rigid barrier protects the heart and lungs against injury during NPWT.</p> <p>Methods</p> <p>Sixteen pigs underwent median sternotomy followed by NPWT at -120 mmHg for 24 hours, in the absence (eight pigs) or presence (eight pigs) of a rigid plastic disc between the heart and the sternal edges. The macroscopic appearance of the heart and lungs was inspected after 12 and 24 hours of NPWT.</p> <p>Results</p> <p>After 24 hours of NPWT at -120 mmHg the area of epicardial petechial bleeding was 11.90 ± 1.10 cm<sup>2 </sup>when no protective disc was used, and 1.15 ± 0.19 cm<sup>2 </sup>when using the disc (p < 0.001). Heart rupture was observed in three of the eight animals treated with NPWT without the disc. Lung rupture was observed in two of the animals, and lung contusion and emphysema were seen in all animals treated with NPWT without the rigid disc. No injury to the heart or lungs was observed in the group of animals treated with NPWT using the rigid disc.</p> <p>Conclusion</p> <p>Inserting a rigid barrier between the heart and the sternum edges offers protection against heart rupture and lung injury during NPWT.</p

    Effects of Curcuma longa (turmeric) on postprandial plasma glucose and insulin in healthy subjects

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Previous animal studies have shown that <it>Curcuma (C.) longa </it>lowers plasma glucose. <it>C. longa </it>may thus be a promising ingredient in functional foods aimed at preventing type 2 diabetes. The purpose of the study is to study the effect of <it>C. longa </it>on postprandial plasma glucose, insulin levels and glycemic index (GI) in healthy subjects.</p> <p>Methods</p> <p>Fourteen healthy subjects were assessed in a crossover trial. A standard 75 g oral glucose tolerance test (OGTT) was administered together with capsules containing a placebo or <it>C. longa</it>. Finger-prick capillary and venous blood samples were collected before, and 15, 30, 45, 60, 90, and 120 min after the start of the OGTT to measure the glucose and insulin levels, respectively.</p> <p>Results</p> <p>The ingestion of 6 g <it>C. longa </it>had no significant effect on the glucose response. The change in insulin was significantly higher 30 min (<it>P </it>= 0.03) and 60 min (<it>P </it>= 0.041) after the OGTT including <it>C. longa</it>. The insulin AUCs were also significantly higher after the ingestion of <it>C. longa</it>, 15 (<it>P </it>= 0.048), 30 (<it>P </it>= 0.035), 90 (<it>P </it>= 0.03), and 120 (<it>P </it>= 0.02) minutes after the OGTT.</p> <p>Conclusions</p> <p>The ingestion of 6 g <it>C. longa </it>increased postprandial serum insulin levels, but did not seem to affect plasma glucose levels or GI, in healthy subjects. The results indicate that <it>C. longa </it>may have an effect on insulin secretion.</p> <p>Trial registration number</p> <p>NCT01029327</p

    Addition of vardenafil into storage solution protects the endothelium in a hypoxia-reoxygenation model

    Get PDF
    OBJECTIVE: Based upon the well known protective effect of intracellular cyclic guanosine monophosphate (cGMP) accumulation, we tested the hypothesis that storage solution enriched with optimal concentration of the phosphodiestherase-5 inhibitor vardenafil could provide better protection of vascular grafts against reperfusion injury after long-term cold ischaemic storage. METHODS: Isolated thoracic aorta obtained from rats underwent 24-h cold ischaemic preservation in physiological saline or vardenafil (10(-11) M)-supplemented saline solution. Reperfusion injury was simulated by hypochlorite (200 muM) exposure for 30 minutes. Endothelium-dependent vasorelaxation was assessed, and histopathological and molecular-biological examination of the aortic tissue were performed. RESULTS: Compared with the control group, the saline group showed significantly attenuated endothelium-dependent maximal relaxation (Rmax) to acetylcholine after hypoxia-reoxygenation, which was significantly improved by vardenafil supplementation (Rmax control: 98 +/- 1%; saline: 48 +/- 6%; vardenafil: 75 +/- 4%; p < .05). Vardenafil treatment significantly reduced DNA strand breaks (control: 10.6 +/- 6.2%; saline: 72.5 +/- 4.0%; vardenafil: 14.2 +/- 5.2%; p < .05) and increased cGMP score in the aortic wall (control: 8.2 +/- 0.6; saline: 4.5 +/- 0.3; vardenafil: 6.7 +/- 0.6; p < .05). CONCLUSIONS: Our results support the view that impairment of intracellular cGMP signalling plays a role in the pathogenesis of the endothelial dysfunction induced by cold storage warm reperfusion, which can be effectively reversed by pharmacological phosphodiesterase-5 inhibition

    Effects on heart pumping function when using foam and gauze for negative pressure wound therapy of sternotomy wounds

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Negative pressure wound therapy (NPWT) has remarkable effects on the healing of poststernotomy mediastinitis. Foam is presently the material of choice for NPWT in this indication. There is now increasing interest in using gauze, as this has proven successful in the treatment of peripheral wounds. It is important to determine the effects of NPWT using gauze on heart pumping function before it can be used for deep sternotomy wounds. The aim was to examine the effects of NPWT when using gauze and foam on the heart pumping function during the treatment of a sternotomy wound.</p> <p>Methods</p> <p>Eight pigs underwent median sternotomy followed by NPWT at -40, -70, -120 and -160 mmHg, using foam or gauze. The heart frequency, cardiac output, mean systemic arterial pressure, mean pulmonary artery pressure, central venous pressure and left atrial pressure were recorded.</p> <p>Results</p> <p>Cardiac output was not affected by NPWT using gauze or foam. Heart frequency decreased during NPWT when using foam, but not gauze. Treatment with foam also lowered the central venous pressure and the left atrial pressure, while gauze had no such effects. Mean systemic arterial pressure, mean pulmonary artery pressure and systemic vascular resistance were not affected by NPWT. Similar haemodynamic effects were observed at all levels of negative pressure studied.</p> <p>Conclusions</p> <p>NPWT using foam results in decreased heart frequency and lower right and left atrial filling pressures. The use of gauze in NPWT did not affect the haemodynamic parameters studied. Gauze may thus provide an alternative to foam for NPWT of sternotomy wounds.</p

    Pressure transduction and fluid evacuation during conventional negative pressure wound therapy of the open abdomen and NPWT using a protective disc over the intestines

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Negative pressure wound therapy (NPWT) has gained acceptance among surgeons, for the treatment of open abdomen, since very high closure rates have been reported with this method, compared to other kinds of wound management for the open abdomen. However, the method has occasionally been associated with increased development of fistulae. We have previously shown that NPWT induces ischemia in the underlying small intestines close to the vacuum source, and that a protective disc placed between the intestines and the vacuum source prevents the induction of ischemia. In this study we compare pressure transduction and fluid evacuation of the open abdomen with conventional NPWT and NPWT with a protective disc.</p> <p>Methods</p> <p>Six pigs underwent midline incision and the application of conventional NPWT and NPWT with a protective disc between the intestines and the vacuum source. The pressure transduction was measured centrally beneath the dressing, and at the anterior abdominal wall, before and after the application of topical negative pressures of -50, -70 and -120 mmHg. The drainage of fluid from the abdomen was measured, with and without the protective disc.</p> <p>Results</p> <p>Abdominal drainage was significantly better (p < 0. 001) using NPWT with the protective disc at -120 mmHg (439 ± 25 ml vs. 239 ± 31 ml), at -70 mmHg (341 ± 27 ml vs. 166 ± 9 ml) and at -50 mmHg (350 ± 50 ml vs. 151 ± 21 ml) than with conventional NPWT. The pressure transduction was more even at all pressure levels using NPWT with the protective disc than with conventional NPWT.</p> <p>Conclusions</p> <p>The drainage of the open abdomen was significantly more effective when using NWPT with the protective disc than with conventional NWPT. This is believed to be due to the more even and effective pressure transduction in the open abdomen using a protective disc in combination with NPWT.</p

    No hypoperfusion is produced in the epicardium during application of myocardial topical negative pressure in a porcine model

    Get PDF
    ABSTRACT: BACKGROUND: Topical negative pressure (TNP), commonly used in wound therapy, has been shown to increase blood flow and stimulate angiogenesis in skeletal muscle. We have previously shown that a myocardial TNP of -50 mmHg significantly increases microvascular blood flow in the myocardium. When TPN is used in wound therapy (on skeletal and subcutaneous tissue) a zone of relative hypoperfusion is seen close to the wound edge. Hypoperfusion induced by TNP is thought to depend on tissue density, distance from the negative pressure source, and the amount negative pressure applied. When applying TNP to the myocardium, a significant, long-standing zone of hypoperfusion could theoretically cause ischemia, and negative effects on the myocardium. The current study was designed to elucidate whether hypoperfusion was produced during myocardial TNP. METHODS: Six pigs underwent median sternotomy. Laser Doppler probes were inserted horizontally into the heart muscle in the LAD area, at depths of approximately, 1-2 mm. The microvascular blood flow was measured before and after the application of a TNP. Analyses were performed before left anterior descending artery (LAD) occlusion (normal myocardium) and after 20 minutes of LAD occlusion (ischemic myocardium). RESULTS: A TNP of -50 mmHg induced a significant increase in microvascular blood flow in normal myocardium (**p = 0.01), while -125 mmHg did not significantly alter the microvascular blood flow. In ischemic myocardium a TNP of -50 mmHg induced a significant increase in microvascular blood flow (*p = 0.04), while -125 mmHg did not significantly alter the microvascular blood flow. CONCLUSION: No hypoperfusion could be observed in the epicardium in neither normal nor ischemic myocardium during myocardial TNP

    Up-regulation of endothelin type B receptors in the human internal mammary artery in culture is dependent on protein kinase C and mitogen-activated kinase signaling pathways

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Up-regulation of vascular endothelin type B (ET<sub>B</sub>) receptors is implicated in the pathogenesis of cardiovascular disease. Culture of intact arteries has been shown to induce similar receptor alterations and has therefore been suggested as a suitable method for, <it>ex vivo</it>, in detail delineation of the regulation of endothelin receptors. We hypothesize that mitogen-activated kinases (MAPK) and protein kinase C (PKC) are involved in the regulation of endothelin ET<sub>B </sub>receptors in human internal mammary arteries.</p> <p>Methods</p> <p>Human internal mammary arteries were obtained during coronary artery bypass graft surgery and were studied before and after 24 hours of organ culture, using <it>in vitro </it>pharmacology, real time PCR and Western blot techniques. Sarafotoxin 6c and endothelin-1 were used to examine the endothelin ET<sub>A </sub>and ET<sub>B </sub>receptor effects, respectively. The involvement of PKC and MAPK in the endothelin receptor regulation was examined by culture in the presence of antagonists.</p> <p>Results</p> <p>The endohtelin-1-induced contraction (after endothelin ET<sub>B </sub>receptor desensitization) and the endothelin ET<sub>A </sub>receptor mRNA expression levels were not altered by culture. The sarafotoxin 6c contraction, endothelin ET<sub>B </sub>receptor protein and mRNA expression levels were increased after organ culture. This increase was antagonized by; (1) PKC inhibitors (10 μM bisindolylmaleimide I and 10 μM Ro-32-0432), and (2) inhibitors of the p38, extracellular signal related kinases 1 and 2 (ERK1/2) and C-jun terminal kinase (JNK) MAPK pathways (10 μM SB203580, 10 μM PD98059 and 10 μM SP600125, respectively).</p> <p>Conclusion</p> <p>In conclusion, PKC and MAPK seem to be involved in the up-regulation of endothelin ET<sub>B </sub>receptor expression in human internal mammary arteries. Inhibiting these intracellular signal transduction pathways may provide a future therapeutic target for hindering the development of vascular endothelin ET<sub>B </sub>receptor changes in cardiovascular disease.</p

    Wound contraction and macro-deformation during negative pressure therapy of sternotomy wounds

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Negative pressure wound therapy (NPWT) is believed to initiate granulation tissue formation via macro-deformation of the wound edge. However, only few studies have been performed to evaluate this hypothesis. The present study was performed to investigate the effects of NPWT on wound contraction and wound edge tissue deformation.</p> <p>Methods</p> <p>Six pigs underwent median sternotomy followed by magnetic resonance imaging in the transverse plane through the thorax and sternotomy wound during NPWT at 0, -75, -125 and -175 mmHg. The lateral width of the wound and anterior-posterior thickness of the wound edge was measured in the images.</p> <p>Results</p> <p>The sternotomy wound decreased in size following NPWT. The lateral width of the wound, at the level of the sternum bone, decreased from 39 ± 7 mm to 30 ± 6 mm at -125 mmHg (p = 0.0027). The greatest decrease in wound width occurred when switching from 0 to -75 mmHg. The level of negative pressure did not affect wound contraction (sternum bone: 32 ± 6 mm at -75 mmHg and 29 ± 6 mm at -175 mmHg, p = 0.0897). The decrease in lateral wound width during NPWT was greater in subcutaneous tissue (14 ± 2 mm) than in sternum bone (9 ± 2 mm), resulting in a ratio of 1.7 ± 0.3 (p = 0.0423), suggesting macro-deformation of the tissue. The anterior-posterior thicknesses of the soft tissue, at 0.5 and 2.5 cm laterally from the wound edge, were not affected by negative pressure.</p> <p>Conclusions</p> <p>NPWT contracts the wound and causes macro-deformation of the wound edge tissue. This shearing force in the tissue and at the wound-foam interface may be one of the mechanisms by which negative pressure delivery promotes granulation tissue formation and wound healing.</p