35 research outputs found

    Mycolactone subverts immunity by selectively blocking the Sec61 translocon

    Get PDF
    Mycolactone, an immunosuppressive macrolide released by the human pathogen Mycobacterium ulcerans, was previously shown to impair Sec61-dependent protein translocation, but the underlying molecular mechanism was not identified. In this study, we show that mycolactone directly targets the alpha subunit of the Sec61 translocon to block the production of secreted and integral membrane proteins with high potency. We identify a single-amino acid mutation conferring resistance to mycolactone, which localizes its interaction site near the lumenal plug of Sec61 alpha. Quantitative proteomics reveals that during T cell activation, mycolactone-mediated Sec61 blockade affects a selective subset of secretory proteins including key signal-transmitting receptors and adhesion molecules. Expression of mutant Sec61 alpha in mycolactone-treated T cells rescued their homing potential and effector functions. Furthermore, when expressed in macrophages, the mycolactone-resistant mutant restored IFN-gamma receptor-mediated antimicrobial responses. Thus, our data provide definitive genetic evidence that Sec61 is the host receptor mediating the diverse immunomodulatory effects of mycolactone and identify Sec61 as a novel regulator of immune cell functions.Peer reviewe

    A downscaled multi-residue strategy for detection of anabolic steroids in bovine urine using gas chromatography tandem mass spectrometry (GC-MS3)

    No full text
    &lt;p&gt;Within the scope of the European Community member states&#039; residue monitoring plan, illicit administration of anabolic steroids is monitored at slaughterhouse level as well as on living animals. At farm level, urine is one of the target matrices to detect possible abuse of anabolic steroid growth promoters. Optimisation of the routinely applied analysis method resulted in a procedure for which high performance liquid chromatographic (HPLC) fractionation prior to GC-MS(n) analysis was no longer required. Analytical results could be obtained within 1 day and only 5 mL urine was needed to carry out the screening procedure. Using the downscaled methodology, all validation criteria described in the European Commission document 2002/657/EC could be fulfilled, and the minimum required performance limits (MRPLs) established for anabolic steroids in urine, could be achieved. A higher GC-MS technique&#039;s specificity was achieved by detecting the steroids using GC-MS3. Nevertheless, it was decided to screen routinely sampled urine with GC-MS2 whereas GC-MS3 was applied to confirm the presence of anabolic steroid residues in suspected sample extracts.&lt;/p&gt;</p
    corecore