47 research outputs found

    Data of cost-optimality and technical solutions for high energy performance buildings in warm climate

    Get PDF
    AbstractThe data reported in this article refers to input and output information related to the research articles entitled Assessment of cost-optimality and technical solutions in high performance multi-residential buildings in the Mediterranean area by ZacĂ  et al. (Assessment of cost-optimality and technical solutions in high performance multi-residential buildings in the Mediterranean area, in press.) and related to the research article Cost-optimal analysis and technical comparison between standard and high efficient mono residential buildings in a warm climate by Baglivo et al. (Energy, 2015, 10.1016/j.energy.2015.02.062, in press)

    MucR binds multiple target sites in the promoter of its own gene and is a heat-stable protein: Is MucR a H-NS-like protein?

    Get PDF
    The protein MucR from Brucella spp. is involved in the expression regulation of genes necessary for host interaction and infection. MucR is a member of the Ros/MucR family, which comprises prokaryotic zinc-finger proteins and includes Ros from Agrobacterium tumefaciens and the Ml proteins from Mesorhizobium loti. MucR from Brucella spp. can regulate the expression of virulence genes and repress its own gene expression. Despite the well-known role played by MucR in the repression of its own gene, no target sequence has yet been identified in the mucR promoter gene. In this study, we provide the first evidence that MucR from Brucella abortus binds more than one target site in the promoter region of its own gene, suggesting a molecular mechanism by which this protein represses its own expression. Furthermore, a circular dichroism analysis reveals that MucR is a heat-stable protein. Overall, the results of this study suggest that MucR might resemble a H-NS protein

    The last step to achieve barrier damage control

    Get PDF
    Heterogeneity characterises inflammatory diseases and different phenotypes and endotypes have been identified. Both innate and adaptive immunity contribute to the immunopathological mechanism of these diseases and barrier damage plays a prominent role triggering type 2 inflammation through the alarmins system, such as anti-Thymic Stromal Lymphopoietin (TSLP). Treatment with anti-TSLP monoclonal antibodies showed efficacy in severe asthma and clinical trials for other eosinophilic diseases are ongoing. The aim of this perspective review is to analyse current advances and future applications of TSLP inhibition to control barrier damage

    COVID-19 : high-resolution computed tomography findings in the first 64 patients admitted to the Hospital of Cremona, the epicentre of the pandemic in Europe

    Get PDF
    Purpose: In December 2019, a new coronavirus (SARS-CoV-2) was identified as being responsible for the pulmonary infection called COVID-19. On 21 February 2020, the first autochthonous case of COVID-19 was detected in Italy. Our goal is to report the most common chest computed tomography (CT) findings identified in 64 patients, in the initial phase of COVID-19. Methods: Sixty-four chest high-resolution computed tomography (HRCT) examinations performed at the Radiology Unit of the Hospital of Cremona, from 22 to 29 February 2020, of 64 patients during first week of hospitalization for COVID-19 were retrospectively evaluated. All cases were confirmed by real-time RT-PCR for SARS-CoV-2. Image analysis was independently conducted by 2 radiologists with 10 years and 1 year of experience in chest imaging. The inter-observer agreement was obtained by applying a Cohen’s κ test. Results: The average age of patients was 67.1 years (± 12.2); men 42 (66%). HRCT was performed on the 5th (± 1.5) day of hospitalization. More frequently, the initial CT changes of the lung show more or less extensive areas of ground-glass, as single pattern or with parenchymal consolidations. Coronavirus lung involvement appears very frequently multi-lobar, bilateral, and it concerns both subpleural and central regions. An excellent agreement (κ: 0.88-1, CI: 0.79-1.01, p < 0.05) concerning CT findings between the 2 operators was reached. Conclusions: Our data suggest that detection of the most frequent pulmonary CT-scan changes, in the early stages of COVID-19, can be performed, with excellent agreement, among readers with different experience, and consequently attribute their exact diagnostic value, in an appropriate clinical and environmental exposure setting

    energy retrofit and environmental sustainability improvement of a historical farmhouse in southern italy

    Get PDF
    Abstract This paper proposes an integrated rehabilitation project of an abandoned farmhouse in a rural area in Southern Italy. The building underwent a functional recovery to become a tourist accommodation. The use of natural materials can reduce energy consumption and carbon footprints considering environmental sustainability aspects. A proper selection of interventions targeted for the specific warm climate has led to benefits for heating, cooling and lighting in the interior spaces. The project also includes the integration of hydraulic facilities and landscaping, such as planting hedges, green barriers and native trees

    Autoimmune hepatitis with eosinophilic infiltration responsive to anti-interleukin-5 receptor treatment: a case report and literature review

    Get PDF
    Inflammatory tissue damage plays a role in the onset, progression, and exacerbation of various chronic autoimmune and metabolic diseases such as autoimmune hepatitis. Here we present a case of autoimmune hepatitis with liver eosinophilic infiltrate in a severe eosinophilic asthma patient who failed conventional immunosuppressive treatment and showed improvement in gastrointestinal symptoms after anti-interleukin-5 receptor treatment. Our case highlights the potential role of eosinophils in initiating or worsening liver inflammation in autoimmune liver disease. The link between eosinophilic inflammation, barrier damage, and chronic autoimmune diseases should be considered in clinical practice

    Genetic and epigenetic mutations affect the DNA binding capability of human ZFP57 in transient neonatal diabetes type 1

    Get PDF
    AbstractIn the mouse, ZFP57 contains three classical Cys2His2 zinc finger domains (ZF) and recognizes the methylated TGCmetCGC target sequence using the first and the second ZFs. In this study, we demonstrate that the human ZFP57 (hZFP57) containing six Cys2His2 ZFs, binds the same methylated sequence through the third and the fourth ZFs, and identify the aminoacids critical for DNA interaction. In addition, we present evidences indicating that hZFP57 mutations and hypomethylation of the TNDM1 ICR both associated with Transient Neonatal Diabetes Mellitus type 1 result in loss of hZFP57 binding to the TNDM1 locus, likely causing PLAGL1 activation

    Economic and thermal evaluation of different uses of an existing structure in a warm climate

    No full text
    Accounting for nearly 40% of final energy consumption, buildings are central to European energy policy. The Directive on Energy Performance of Buildings establishes a benchmarking system known as cost-optimality to set minimum energy performance requirements in new and existing buildings. This paper applies the cost-optimal methodology to an existing structure located in the Mediterranean area (Southern Italy). The building is composed of two units that have been considered for different uses: hotel and multi-residential. Several energy efficiency and renewable measures have been implemented both individually and as part of packages of measures. The cost-optimal solution has been identified as able to optimize energy consumption and costs from financial and macroeconomic perspectives. The first reference building (hotel use) shows a maximum reduction of primary energy and CO2 emission of about 42%, falling within the CasaClima energy class D, while the second reference building (residential use) achieves a value of 88% for primary energy and 85% for CO2 emissions, falling into class B. Thermal dispersions through the envelope can be limited using a suitable combination of insulating materials while a variety of technical variants are selected, such as VRF (variant refrigerant flow) systems, heat pumps with fan coils associated with controlled mechanical ventilation, solar thermal and photovoltaic. This paper illustrates the development of energy retrofit projects, in order to reach a balance between efficiency measures and costs for a building having two different uses, providing guidance to similar case studies related to a warm climate
    corecore