80 research outputs found
Obesity-related hypertension and chronic kidney disease: from evaluation to management
With the recent obesity pandemic, obesity-related hypertension and its complications (e.g., heart failure, coronary disease, and chronic kidney disease [CKD]) are gaining attention in clinical and research fields. Obesity-related hypertension frequently precedes the onset of CKD and aggravates its progression. In this review, we discuss the role of visceral fat in the pathophysiology of obesity-related hypertension and the potential therapeutic strategies for its prevention and management. Various factors, including the sympathetic nervous system, renin-angiotensin-aldosterone system, and inflammatory pathways, are intricately involved in the pathogenesis of obesity-related hypertension. These factors individually and jointly contribute to the development of hypertension (usually sodium-sensitive or resistant hypertension) and, ultimately, to the progression of CKD. From a clinical standpoint, a decline in renal function in advanced CKD further makes blood pressure control challenging since only a few options are available for blood pressure-lowering medications. Proactive lifestyle modification, pharmacological treatment for obesity, and bariatric surgery can be considered for obesity control and management. Furthermore, intensive blood pressure control is required to prevent and halt the development and progression of CKD
Feasibility, credence, and usefulness of out-of-office cuffless blood pressure monitoring using smartwatch: a population survey
Background
Cuffless blood pressure (BP) measurement, enabled by recent advances in wearable devices, allows for BP monitoring in daily life. This study aims to evaluate the feasibility, cresdence, and usefulness of cuffless BP monitoring through a population survey.
Methods
During the "Daily BP Measurement with Your Galaxy Watch" campaign held by the Korean Society of Hypertension, participants were asked to share their experiences with cuffless BP measurement using a smartwatch application through an online survey. The questionnaire included questions about age, underlying medical conditions, smartwatch utilization, experience with BP calibration, the reliability of BP values measured by a smartwatch, and willingness to use the BP monitoring function in the future.
Results
A total of 1071 participants responded to the survey. The largest age group (decile) was 50-59 years old (33.3%), followed by 40-49 years old (29.9%). Although nearly half of the participants (47.5%) had no chronic diseases, 40.1% reported having hypertension. BP monitoring was the most frequently utilized smartwatch function (95.8%), followed by heart rate measurement (87.1%). 31.8% of participants reported that BP values measured by the smartphone application were "very accurate and helpful," while 63.5% rated them as "slightly lower (44.4%)" or "higher (19.1%)" compared to the standard home BP monitoring device. 93% of the participants reported utilizing the BP monitoring function at least once a week. Regarding the BP calibration process, most participants (93.9%) calibrated the BP measurement application themselves, and 50.8% rated the difficulty level as "very easy."
Conclusion
Cuffless BP measurement using a smartwatch application was feasible in the general population, including the self-calibration process. However, the satisfaction level in terms of accuracy is still modest, indicating a need for further development
Novel Swine-Origin Influenza A (H1N1) Viral Encephalitis
The World Health Organization declared that a new strain of novel swine-origin influenza A (H1N1) virus was responsible for the pandemic infection in June 2009. We report a case of encephalitis diagnosed as the H1N1 virus infection. We describe a 17-year-old patient who had a seizure attack, diagnosed with a H1N1 virus infection via real time reverse-transcriptase polymerase chain reaction (RT-PCR). The H1N1 virus infection can be causative of the encephalitis, as with other influenza virus infections. Careful monitoring is essential for reducing complications
2018 Korean Society of Hypertension Guidelines for the management of hypertension: part II-diagnosis and treatment of hypertension
The standardized techniques of blood pressure (BP) measurement in the clinic are emphasized and it is recommended to replace the mercury sphygmomanometer by a non-mercury sphygmomanometer. Out-of-office BP measurement using home BP monitoring (HBPM) or ambulatory BP monitoring (ABPM) and even automated office BP (AOBP) are recommended to correctly measure the patients genuine BP. Hypertension (HTN) treatment should be individualized based on cardiovascular (CV) risk and the level of BP. Based on the recent clinical study data proving benefits of intensive BP lowering in the high risk patients, the revised guideline recommends the more intensive BP lowering in high risk patients including the elderly population. Lifestyle modifications, mostly low salt diet and weight reduction, are strongly recommended in the population with elevated BP and prehypertension and all hypertensive patients. In patients with BP higher than 160/100 mmHg or more than 20/10 mmHg above the target BP, two drugs can be prescribed in combination to maximize the antihypertensive effect and to achieve rapid BP control. Especially, single pill combination drugs have multiple benefits, including maximizing reduction of BP, minimizing adverse effects, increasing adherence, and preventing cardiovascular disease (CVD) and target organ damage
Home blood pressure monitoring: a position statement from the Korean Society of Hypertension Home Blood Pressure Forum
Abstract
Home blood pressure measurement (HBPM) has the advantage of measuring blood pressure (BP) multiple times over a long period. HBPM effectively diagnoses stress-induced transient BP elevations (i.e., white coat hypertension), insufficient BP control throughout the day (i.e., masked hypertension), and even BP variability. In most cases, HBPM may increase self-awareness of BP, increasing the compliance of treatment. Cumulative evidence has reported better improved predictive values of HBPM in cardiovascular morbidity and mortality than office BP monitoring. In this position paper, the Korean Society of Hypertension Home Blood Pressure Forum provides comprehensive information and clinical importance on HBPM
The Impact of the Aortic Pulse Wave Velocity on the Cardiovascular Outcomes of Hemodialysis Patients
The aims of our study were to identify the risk factors for an increased aortic pulse wave velocity (AoPWV) and to assess the impact of the AoPWV on the cerebro-cardiovascular (CV) outcomes of hemodialysis (HD) patients. Seventy two HD patients were included, and the AoPWV, the echocardiography and the biochemical parameters were measured. After dividing the patients into tertiles according to the AoPWV values, we defined the low, the middle and the high AoPWV groups. The patients in the high AoPWV group showed a significantly higher age and high-sensitivity C-reactive protein level, a greater prevalence of diabetes and statin use, left ventricular hypertrophy, average pulse pressure (PP), AoPWV and left ventricular mass index and a lower serum albumin level than those in the low AoPWV group (p<0.05). On multivariate regression analysis of the AoPWV, age and the average PP were independently related to the AoPWV (p<0.05). On the multivariate Cox analysis for CV outcomes, the AoPWV and the average PP remained significant independent predictors of CV events. Our data suggest that an increased AoPWV is an independent predictor for the CV outcomes of HD patients
- …