15 research outputs found

    Usefulness of multiplex PCR methods and respiratory viruses' distribution in children below 15 years old according to age, seasons and clinical units in France: A 3 years retrospective study.

    No full text
    BACKGROUND:To date, only influenza and RSV testing are recommended for respiratory viruses' detection in paediatric units. In this study, we described, according to seasons, ages and clinical units, the results obtained in children (<15 years old) by multiplex-PCR (mPCR) tests allowing a quick and wide range detection of all respiratory viruses. These results were also compared with RSV specific detection. METHODS:All nasopharyngeal mPCR and RSV tests requested by clinicians in our French teaching hospitals group between 2011 and 2014 were retrospectively included. All repeated samples for the same children in the same month were discarded. RESULTS:Of the 381 mPCR tests (344 children) performed, 51.4% were positive. Positivity and viral co-infection rates were higher in the 6-36 months old strata (81% and 25%, p<0.0001 and p = 0.04, respectively). Viral distribution showed strong variations across ages. During specific influenza epidemic periods, only 1/39 (2.5%) mPCR tests were positive for influenza and 19/39 (48.7%) for other viruses. During specific RSV epidemic periods, only 8/46 (17.4%) mPCR tests were positive for RSV and 14/46 (30.4%) for other viruses. 477/1529 (31.2%) of RSV immunochromatography-tests were positive. Among the negatives immunochromatography-test also explored by mPCR, 28/62 (31%) were positive for other respiratory viruses. CONCLUSION:This study provides a wide description of respiratory viruses' distribution among children in hospital settings using mPCR over 3 years. It emphasizes the number of undiagnosed respiratory viruses according to the current diagnosis practice in France and gives a better picture of respiratory viruses identified in hospital settings by mPCR all over the year in France

    Raltegravir Concentrations in the Genital Tract of HIV-1-Infected Women Treated with a Raltegravir-Containing Regimen (DIVA 01 Study)▿

    No full text
    We studied the penetration of raltegravir and HIV shedding in the genital tract among 14 HIV-1-infected women receiving a raltegravir-containing regimen who had <40 copies/ml blood plasma (BP) HIV RNA. None of the cervicovaginal fluid (CVF) samples showed detectable HIV RNA. Median raltegravir concentrations were 235 ng/ml in BP and 93 ng/ml in CVF, with a CVF/BP ratio of approximately 2.3. This good penetration of raltegravir may contribute to the control of viral replication in the female genital tract

    Performance evaluation of two SARS-CoV-2 IgG/IgM rapid tests (Covid-Presto and NG-Test) and one IgG automated immunoassay (Abbott)

    No full text
    International audienceThe aim of this study was to assess the analytical performances, sensitivity and specificity, of two rapid tests (Covid- Presto® test rapid Covid-19 IgG/IgM and NG-Test® IgM-IgG COVID-19) and one automated immunoassay (Abbott SARS-CoV-2 IgG) for detecting anti- SARS-CoV-2 antibodies. This study was performed with: (i) a positive panel constituted of 88 SARS-CoV-2 specimens collected from patients with a positive SARS-CoV-2 RT-PCR, and (ii) a negative panel of 120 serum samples, all collected before November 2019, including 64 samples with a cross-reactivity panel. Sensitivity of Covid-Presto® test for IgM and IgG was 78.4% and 92.0%, respectively. Sensitivity of NG-Test® for IgM and IgG was 96.6% and 94.9%, respectively. Sensitivity of Abbott IgG assay was 96.5% showing an excellent agreement with the two rapid tests (κ = 0.947 and κ = 0.936 for NGTest ® and Covid-Presto® test, respectively). An excellent agreement was also observed between the two rapid tests (κ = 0.937). Specificity for IgM was 100% and 86.5% for Covid-Presto® test and NG-Test®, respectively. Specificity for IgG was 92.0%, 94.9% and 96.5% for Covid-Presto®, NGTest ®, and Abbott, respectively. Most of the false positive results observed with NG-Test® resulted from samples containing malarial antibodies. In conclusion, performances of these 2 rapid tests are very good and comparable to those obtained with automated immunoassay, except for IgM specificity with the NG-Test®. Thus, isolated IgM should be cautiously interpreted due to the possible false-positive reactions with this test. Finally, before their large use, the rapid tests must be reliably evaluated with adequate and large panel including early seroconversion and possible cross-reactive samples

    Detection of SARS-CoV-2 N-antigen in blood during acute COVID-19 provides a sensitive new marker and new testing alternatives

    No full text
    International audienceOBJECTIVES: Molecular assays on nasopharyngeal swabs remain the cornerstone of COVID-19 diagnostic. The high technicalities of nasopharyngeal sampling and molecular assays, as well as scarce resources of reagents, limit our testing capabilities. Several strategies failed, to date, to fully alleviate this testing process (e.g. saliva sampling or antigen testing on nasopharyngeal samples). We assessed the clinical performances of SARS-CoV-2 nucleocapsid antigen (N-antigen) ELISA detection in serum or plasma using the COVID-19 Quantigene® (AAZ, France) assay. METHODS: Performances were determined on 63 sera from 63 non-COVID patients and 227 serum samples (165 patients) from the French COVID and CoV-CONTACT cohorts with RT-PCR confirmed SARS-CoV-2 infection, including 142 serum (114 patients) obtained within 14 days after symptoms’ onset. RESULTS: Specificity was 98.4% (95% confidence interval [CI], 95.3 to 100). Sensitivity was 79.3% overall (180/227, 95% CI, 74.0 to 84.6) and 93.0% (132/142, 95% CI, 88.7 to 97.2) within 14 days after symptoms onset. 91 included patients had a sera and nasopharyngeal swabs collected in the same 24 hours. Among those with high nasopharyngeal viral loads, i.e. Ct value below 30 and 33, only 1/50 and 4/67 tested negative for N-antigenemia, respectively. Among those with a negative nasopharyngeal RT-PCR, 8/12 presented positive N-antigenemia; the lower respiratory tract was explored for 6 of these 8 patients, showing positive RT-PCR in 5 cases. CONCLUSION: This is the first evaluation of a commercially available serum N-antigen detection assay. It presents a robust specificity and sensitivity within the first 14 days after symptoms onset. This approach provides a valuable new option for COVID-19 diagnosis, only requiring a blood draw and easily scalable in all clinical laboratories

    SARS-CoV-2 N-antigenemia: A new COVID-19 marker and a potential alternative to nucleic acid amplification techniques

    No full text
    Background Molecular assays on nasopharyngeal swabs remain the cornerstone of COVID-19 diagnostic. Despite massive worldwide efforts, the high technicalities of nasopharyngeal sampling and molecular assays, as well as scarce resources of reagents, limit our testing capabilities. Several strategies failed, to date, to fully alleviate this testing process (e.g. saliva sampling or antigen testing on nasopharyngeal samples). We assessed the performances of a new ELISA microplate assay quantifying SARS-CoV-2 nucleocapsid antigen (N-antigen) in serum or plasma. Methods The specificity of the assay, determined on 63 non-COVID patients, was 98.4% (95% confidence interval [CI], 85.3 to 100). Performances were determined on 227 serum samples from 165 patients with RT-PCR confirmed SARS-CoV-2 infection included in the French COVID and CoV-CONTACT cohorts. Findings Sensitivity was 132/142, 93.0% (95% CI, 84.7 to 100), within the first two weeks after symptoms onset. A subset of 73 COVID-19 patients had a serum collected within 24 hours following or preceding a positive nasopharyngeal swab. Among patients with high nasopharyngeal viral loads, Ct value below 30 and 33, only 1/50 and 4/67 tested negative for N-antigenemia, respectively. Among patients with a negative nasopharyngeal RT-PCR, 8/12 presented positive N-antigenemia. The lower respiratory tract was explored for 6/8 patients, showing positive PCR in 5 cases. Interpretation This is the first demonstration of the N-antigen antigenemia during COVID-19. Its detection presented a robust sensitivity, especially within the first 14 days after symptoms onset and high nasopharyngeal viral loads. These findings have to be confirmed with higher representation of outpatients. This approach could provide a valuable new option for COVID-19 diagnosis, only requiring a blood draw and easily scalable in all clinical laboratories
    corecore