499 research outputs found

    Study of the time and space distribution of beta+ emitters from 80 MeV/u carbon ion beam irradiation on PMMA

    Full text link
    Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear 511\ \kilo\electronvolt photons produced by positrons annihilation from β+\beta^+ emitters created by the beam. This paper reports rate measurements of the 511\ \kilo\electronvolt photons emitted after the interactions of a 80\ \mega\electronvolt / u fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a Poly-methyl methacrylate target. The time evolution of the β+\beta^+ rate was parametrized and the dominance of 11C^{11}C emitters over the other species (13N^{13}N, 15O^{15}O, 14O^{14}O) was observed, measuring the fraction of carbon ions activating β+\beta^+ emitters A0=(10.3±0.7)103A_0=(10.3\pm0.7)\cdot10^{-3}. The average depth in the PMMA of the positron annihilation from β+\beta^+ emitters was also measured, D_{\beta^+}=5.3\pm1.1\ \milli\meter, to be compared to the expected Bragg peak depth D_{Bragg}=11.0\pm 0.5\ \milli\meter obtained from simulations

    A comparison of the development of audiovisual integration in children with autism spectrum disorders and typically developing children

    Get PDF
    This study aimed to investigate the development of audiovisual integration in children with Autism Spectrum Disorder (ASD). Audiovisual integration was measured using the McGurk effect in children with ASD aged 7–16 years and typically developing children (control group) matched approximately for age, sex, nonverbal ability and verbal ability. Results showed that the children with ASD were delayed in visual accuracy and audiovisual integration compared to the control group. However, in the audiovisual integration measure, children with ASD appeared to ‘catch-up’ with their typically developing peers at the older age ranges. The suggestion that children with ASD show a deficit in audiovisual integration which diminishes with age has clinical implications for those assessing and treating these children

    Charged particle's flux measurement from PMMA irradiated by 80 MeV/u carbon ion beam

    Full text link
    Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance in the design of any dose monitoring device and is eagerly needed to tune Monte Carlo simulations. We report the measurements done with charged secondary particles produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the INFN Laboratori Nazionali del Sud, Catania, with a Poly-methyl methacrylate target. Charged secondary particles, produced at 90°\degree with respect to the beam axis, have been tracked with a drift chamber, while their energy and time of flight has been measured by means of a LYSO scintillator. Secondary protons have been identified exploiting the energy and time of flight information, and their emission region has been reconstructed backtracking from the drift chamber to the target. Moreover a position scan of the target indicates that the reconstructed emission region follows the movement of the expected Bragg peak position. Exploting the reconstruction of the emission region, an accuracy on the Bragg peak determination in the submillimeter range has been obtained. The measured differential production rate for protons produced with EkinProd>E^{\rm Prod}_{\rm kin} > 83 MeV and emitted at 90°\degree with respect to the beam line is: dNP/(dNCdΩ)(EkinProd>83 MeV,θ=90°)=(2.69±0.08stat±0.12sys)×104sr1dN_{\rm P}/(dN_{\rm C}d\Omega)(E^{\rm Prod}_{\rm kin} > 83 {\rm ~MeV}, \theta=90\degree)= (2.69\pm 0.08_{\rm stat} \pm 0.12_{\rm sys})\times 10^{-4} sr^{-1}.Comment: 13 pages, 9 figure

    A combined analysis technique for the search for fast magnetic monopoles with the MACRO detector

    Full text link
    We describe a search method for fast moving (β>5×103\beta > 5 \times 10^{-3}) magnetic monopoles using simultaneously the scintillator, streamer tube and track-etch subdetectors of the MACRO apparatus. The first two subdetectors are used primarily for the identification of candidates while the track-etch one is used as the final tool for their rejection or confirmation. Using this technique, a first sample of more than two years of data has been analyzed without any evidence of a magnetic monopole. We set a 90% CL upper limit to the local monopole flux of 1.5×1015cm2s1sr11.5 \times 10^{-15} cm^{-2} s^{-1} sr^{-1} in the velocity range 5×103β0.995 \times 10^{-3} \le \beta \le 0.99 and for nucleon decay catalysis cross section smaller than 1mb\sim 1 mb.Comment: 29 pages (12 figures). Accepted by Astroparticle Physic

    Muon Energy Estimate Through Multiple Scattering with the Macro Detector

    Get PDF
    Muon energy measurement represents an important issue for any experiment addressing neutrino induced upgoing muon studies. Since the neutrino oscillation probability depends on the neutrino energy, a measurement of the muon energy adds an important piece of information concerning the neutrino system. We show in this paper how the MACRO limited streamer tube system can be operated in drift mode by using the TDC's included in the QTPs, an electronics designed for magnetic monopole search. An improvement of the space resolution is obtained, through an analysis of the multiple scattering of muon tracks as they pass through our detector. This information can be used further to obtain an estimate of the energy of muons crossing the detector. Here we present the results of two dedicated tests, performed at CERN PS-T9 and SPS-X7 beam lines, to provide a full check of the electronics and to exploit the feasibility of such a multiple scattering analysis. We show that by using a neural network approach, we are able to reconstruct the muon energy for Eμ<E_\mu<40 GeV. The test beam data provide an absolute energy calibration, which allows us to apply this method to MACRO data.Comment: 25 pages, 11 figures, Submitted to Nucl. Instr. & Meth.

    Search for Nucleon Decays induced by GUT Magnetic Monopoles with the MACRO Experiment

    Get PDF
    The interaction of a Grand Unification Magnetic Monopole with a nucleon can lead to a barion-number violating process in which the nucleon decays into a lepton and one or more mesons (catalysis of nucleon decay). In this paper we report an experimental study of the effects of a catalysis process in the MACRO detector. Using a dedicated analysis we obtain new magnetic monopole (MM) flux upper limits at the level of 31016cm2s1sr1\sim 3\cdot 10^{-16} cm^{-2} s^{-1} sr^{-1} for 1.1104β51031.1\cdot 10^{-4} \le |\beta| \le 5\cdot 10^{-3}, based on the search for catalysis events in the MACRO data. We also analyze the dependence of the MM flux limit on the catalysis cross section.Comment: 12 pages, Latex, 10 figures and 2 Table

    Nuclearite search with the MACRO detector at Gran Sasso

    Full text link
    In this paper we present the results of a search for nuclearites in the penetrating cosmic radiation using the scintillator and track-etch subdetectors of the MACRO apparatus. The analyses cover the beta =v/c range at the detector depth (3700 hg/cm^2) 10^-5 < beta < 1; for beta = 2 x 10^-3 the flux limit is 2.7 x 10^-16 cm^-2 s^-1 sr^-1 for an isotropic flux of nuclearites, and twice this value for a flux of downgoing nuclearites.Comment: 16 pages, 4 Encapsulated Postscript figures, uses article.sty. Submitted to The European Physical Journal

    Atmospheric neutrino induced muons in the MACRO detector

    Get PDF
    A measurement of the flux of neutrino-induced muons using the MACRO detector is presented. Different event topologies, corresponding to different neutrino parent energies can be detected. The upward throughgoing muon sample is the larger event sample. The observed upward-throughgoing muons are 26% fewer than expected and the zenith angle distribution does not fit with the expected one. Assuming neutrino oscillations, both measurements suggest maximum mixing and Dm2 of a few times 10-3 eV2. The other samples are due to the internally produced events and to upward-going stopping muons. These data show a regular deficit of observed events in each angular bin, as expected assuming neutrino oscillations with maximum mixing, in agreement with the analysis of the upward-throughgoing muon sample.Comment: 7 pages 6 figures to appear in the proceedings of XVIII International Conference on Neutrino Physics and Astrophysics (Neutrino'98), Takayama, Japan 4-9 June, 199

    The Observation of Up-going Charged Particles Produced by High Energy Muons in Underground Detectors

    Get PDF
    An experimental study of the production of up-going charged particles in inelastic interactions of down-going underground muons is reported, using data obtained from the MACRO detector at the Gran Sasso Laboratory. In a sample of 12.2 10^6 single muons, corresponding to a detector livetime of 1.55 y, 243 events are observed having an up-going particle associated with a down-going muon. These events are analysed to determine the range and emission angle distributions of the up-going particle, corrected for detection and reconstruction efficiency. Measurements of the muon neutrino flux by underground detectors are often based on the observation of through-going and stopping muons produced in νμ\nu_\mu interactions in the rock below the detector. Up-going particles produced by an undetected down-going muon are a potential background source in these measurements. The implications of this background for neutrino studies using MACRO are discussed.Comment: 18 pages, 9 figures. Accepted by Astrop. Physic

    Measurement of the residual energy of muons in the Gran Sasso underground Laboratories

    Full text link
    The MACRO detector was located in the Hall B of the Gran Sasso underground Laboratories under an average rock overburden of 3700 hg/cm^2. A transition radiation detector composed of three identical modules, covering a total horizontal area of 36 m^2, was installed inside the empty upper part of the detector in order to measure the residual energy of muons. This paper presents the measurement of the residual energy of single and double muons crossing the apparatus. Our data show that double muons are more energetic than single ones. This measurement is performed over a standard rock depth range from 3000 to 6500 hg/cm^2.Comment: 28 pages, 9 figure
    corecore