21 research outputs found
Influence of oral contrast type and volume on patient experience and quality of luminal distension at MR Enterography in Crohn's disease:an observational study of patients recruited to the METRIC trial
OBJECTIVES: To compare the distention quality and patient experience of oral mannitol and polyethylene glycol (PEG) for MRE. METHODS: This study is a retrospective, observational study of a subset of patients enrolled in a multicentre, prospective trial evaluating the diagnostic accuracy of MRE for small bowel Crohnâs. Overall and segmental MRE small bowel distention, from 105 patients (64 F, mean age 37) was scored from 0 = poor to 4 = excellent by two experienced observers (68 [65%] mannitol and 37 [35%] PEG). Additionally, 130 patients (77 F, mean age 34) completed a questionnaire rating tolerability of various symptoms immediately and 2 days after MRE (85 [65%] receiving mannitol 45 [35%] receiving PEG). Distension was compared between agents and between those ingesting †1 L or > 1 L of mannitol using the test of proportions. Tolerability grades were collapsed into âvery tolerable,â âmoderately tolerable,â and ânot tolerable.â RESULTS: Per patient distension quality was similar between agents (âexcellentâ or âgoodâ in 54% [37/68] versus 46% [17/37]) with mannitol and PEG respectively. Jejunal distension was significantly better with mannitol compared to PEG (40% [27/68] versus 14% [5/37] rated as excellent or good respectively). There was no significant difference according to the volume of mannitol ingested. Symptom tolerability was comparable between agents, although fullness following MRE was graded as âvery tolerableâ in 27% (12/45) of patients ingesting PEG, verses 44% (37/84) ingesting mannitol, difference 17% (95% CI 0.6 to 34%). CONCLUSION: Mannitol-based solutions and PEG generally achieve comparable distension quality and side effect profiles, although jejunal distension is better quality with mannitol. Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol. KEY POINTS: âą Mannitol-based and PEG-based oral preparation agents generally achieve comparable distension quality for MRE with the exception of the jejunum which is better distended with mannitol. âą Mannitol-based and PEG-based oral preparation agents used for MRE have similar side effect profiles. âą Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-022-08614-9
Diagnostic performance of sonographic activity scores for adult terminal ileal Crohnâs disease compared to magnetic resonance and histological reference standards:experience from the METRIC trial
Objectives: The simple ultrasound activity score for Crohnâs disease (SUS-CD) and bowel ultrasound score (BUSS) are promising intestinal ultrasound (IUS) indices of CD, but studied mainly in small settings with few sonographers. We compared SUS-CD and BUSS against histological and magnetic resonance enterography (MRE) reference standards in a post hoc analysis of a prospective multicentre, multireader trial. Methods: Participants recruited to the METRIC trial (ISRCTN03982913) were studied, including those with available terminal ileal (TI) biopsies. Sensitivity and specificity of SUS-CD and BUSS for TI CD activity were calculated with 95% confidence intervals (CI), from the prospective observations of the original METRIC trial sonographers against the histological activity index (HAI) and the simplified magnetic resonance index of activity (sMARIA). Results: We included 284 patients (median 31.5 years, IQR 23â46) from 8 centres, who underwent IUS and MRE. Of these, 111 patients had available terminal ileal biopsies with HAI scoring. Against histology, sensitivity and specificity for active disease were 79% (95% CI 69â86%) and 50% (31â69%) for SUS-CD, and 66% (56â75%) and 68% (47â84%) for BUSS, respectively. Compared to sMARIA, the sensitivity and specificity for active CD were 81% (74â86%) and 75% (66â83%) for SUS-CD, and 68% (61â74%) and 85% (76â91%) for BUSS, respectively. The sensitivity of SUS-CD was significantly greater than that of BUSS against HAI and sMARIA (p < 0.001), but its specificity was significantly lower than of BUSS against the MRE reference standard (p = 0.003). Conclusions: Particularly when compared to MRE activity scoring, SUS-CD and BUSS are promising tools in a real-world clinical setting.Clinical relevance statement: When tested using data from a multicentre, multireader diagnostic accuracy trial, the simple ultrasound activity score for Crohnâs disease (SUS-CD) and bowel ultrasound score (BUSS) were clinically viable intestinal ultrasound indices that were reasonably sensitive and specific for terminal ileal Crohnâs disease, especially when compared to a magnetic resonance reference standard.</p
Influence of diffusion weighted imaging and contrast enhanced T1 sequences on the diagnostic accuracy of magnetic resonance enterography for Crohn's disease
OBJECTIVES: To evaluate the additional diagnostic benefit of diffusion weighted imaging (DWI) and contrast enhanced (CE) images during MR enterography (MRE) of Crohn's disease.METHODS: Datasets from 73 patients (mean age 32; 40 male) (28 new-diagnosis, 45 relapsed) were read independently by two radiologists selected from a pool of 13. Radiologists interpreted datasets using three sequential sequence blocks: (1) T2 weighted and steady state free precession gradient echo (SSFP) images alone (T2^); (2) T2 weighted and SSFP images with DWI (T2 + DWI^) and; (3) T2 weighted images, SSFP, DWI and post-contrast enhanced (CE) T1 images (T2 + DWI + CE^), documenting presence, location, and activity of small bowel disease. For each sequence block, sensitivity and specificity (readers combined) was calculated against an outcome-based construct reference standard.RESULTS: 59/73 patients had small bowel disease. Per-patient sensitivity for disease detection was essentially identical (80 % [95 % CI 72, 86], 81 % [73,87], and 79 % [71,86] for T2^, T2 + DWI^and T2 + DWI + CE^respectively). Specificity was identical (82 % [64 to 92]). Per patient sensitivity for disease extent was 56 % (47,65), 56 % (47,65) and 52 % (43 to 61) respectively, and specificity was 82 % (64 to 92) for all blocks. Sensitivity for active disease was 97 % (90,99), 97 % (90,99) and 98 % (92,99), and specificity was also comparable between all sequence combination reads. Results were consistent across segments and newly diagnosed/relapse patients.CONCLUSION: There is no additional diagnostic benefit of adding either DWI or CE to T2 FSE and SSFP sequences for evaluating small bowel Crohn's disease, suggesting MRE protocols can be simplified safely.</p
Diagnostic performance of sonographic activity scores for adult terminal ileal Crohn's disease compared to magnetic resonance and histological reference standards: experience from the METRIC trial
OBJECTIVES: The simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) are promising intestinal ultrasound (IUS) indices of CD, but studied mainly in small settings with few sonographers. We compared SUS-CD and BUSS against histological and magnetic resonance enterography (MRE) reference standards in a post hoc analysis of a prospective multicentre, multireader trial. METHODS: Participants recruited to the METRIC trial (ISRCTN03982913) were studied, including those with available terminal ileal (TI) biopsies. Sensitivity and specificity of SUS-CD and BUSS for TI CD activity were calculated with 95% confidence intervals (CI), from the prospective observations of the original METRIC trial sonographers against the histological activity index (HAI) and the simplified magnetic resonance index of activity (sMARIA). RESULTS: We included 284 patients (median 31.5 years, IQR 23-46) from 8 centres, who underwent IUS and MRE. Of these, 111 patients had available terminal ileal biopsies with HAI scoring. Against histology, sensitivity and specificity for active disease were 79% (95% CI 69-86%) and 50% (31-69%) for SUS-CD, and 66% (56-75%) and 68% (47-84%) for BUSS, respectively. Compared to sMARIA, the sensitivity and specificity for active CD were 81% (74-86%) and 75% (66-83%) for SUS-CD, and 68% (61-74%) and 85% (76-91%) for BUSS, respectively. The sensitivity of SUS-CD was significantly greater than that of BUSS against HAI and sMARIA (p < 0.001), but its specificity was significantly lower than of BUSS against the MRE reference standard (p = 0.003). CONCLUSIONS: Particularly when compared to MRE activity scoring, SUS-CD and BUSS are promising tools in a real-world clinical setting. CLINICAL RELEVANCE STATEMENT: When tested using data from a multicentre, multireader diagnostic accuracy trial, the simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) were clinically viable intestinal ultrasound indices that were reasonably sensitive and specific for terminal ileal Crohn's disease, especially when compared to a magnetic resonance reference standard. KEY POINTS: The simple ultrasound activity score for Crohn's disease and bowel ultrasound score are promising intestinal ultrasound indices of Crohn's disease but to date studied mainly in small settings with few sonographers. Compared to histology and the magnetic resonance reference standard in a multicentre, multireader setting, the sensitivity of simple ultrasound activity score for Crohn's disease is significantly greater than that of bowel ultrasound score. The specificity of simple ultrasound activity score for Crohn's disease was significantly lower than that of bowel ultrasound score compared to the magnetic resonance enterography reference standard. The specificity of both indices was numerically higher when the magnetic resonance enterography reference standard was adopted
Multivariable prognostic modelling to improve prediction of colorectal cancer recurrence: the PROSPeCT trial
OBJECTIVE: Improving prognostication to direct personalised therapy remains an unmet need. This study prospectively investigated promising CT, genetic, and immunohistochemical markers to improve the prediction of colorectal cancer recurrence. MATERIAL AND METHODS: This multicentre trial (ISRCTN 95037515) recruited patients with primary colorectal cancer undergoing CT staging from 13 hospitals. Follow-up identified cancer recurrence and death. A baseline model for cancer recurrence at 3 years was developed from pre-specified clinicopathological variables (age, sex, tumour-node stage, tumour size, location, extramural venous invasion, and treatment). Then, CT perfusion (blood flow, blood volume, transit time and permeability), genetic (RAS, RAF, and DNA mismatch repair), and immunohistochemical markers of angiogenesis and hypoxia (CD105, vascular endothelial growth factor, glucose transporter protein, and hypoxia-inducible factor) were added to assess whether prediction improved over tumour-node staging alone as the main outcome measure. RESULTS: Three hundred twenty-six of 448 participants formed the final cohort (226 male; mean 66â±â10 years. 227 (70%) had â„âT3 stage cancers; 151 (46%) were node-positive; 81 (25%) developed subsequent recurrence. The sensitivity and specificity of staging alone for recurrence were 0.56 [95% CI: 0.44, 0.67] and 0.58 [0.51, 0.64], respectively. The baseline clinicopathologic model improved specificity (0.74 [0.68, 0.79], with equivalent sensitivity of 0.57 [0.45, 0.68] for high vs medium/low-risk participants. The addition of prespecified CT perfusion, genetic, and immunohistochemical markers did not improve prediction over and above the clinicopathologic model (sensitivity, 0.58-0.68; specificity, 0.75-0.76). CONCLUSION: A multivariable clinicopathological model outperformed staging in identifying patients at high risk of recurrence. Promising CT, genetic, and immunohistochemical markers investigated did not further improve prognostication in rigorous prospective evaluation. CLINICAL RELEVANCE STATEMENT: A prognostic model based on clinicopathological variables including age, sex, tumour-node stage, size, location, and extramural venous invasion better identifies colorectal cancer patients at high risk of recurrence for neoadjuvant/adjuvant therapy than stage alone. KEY POINTS: Identification of colorectal cancer patients at high risk of recurrence is an unmet need for treatment personalisation. This model for recurrence, incorporating many patient variables, had higher specificity than staging alone. Continued optimisation of risk stratification schema will help individualise treatment plans and follow-up schedules
Magnetic resonance enterography, small bowel ultrasound and colonoscopy to diagnose and stage Crohnâs disease; patient acceptability, and perceived burden
Objectives: To compare patient acceptability and burden of magnetic resonance enterography (MRE) and ultrasound (US) to each other, and to other enteric investigations, particularly colonoscopy.
Methods: 159 patients (mean age 38, 94 female) with newly diagnosed or relapsing Crohnâs disease, prospectively recruited to a multicentre diagnostic accuracy study comparing MRE and US, completed an experience questionnaire on the burden and acceptability of small bowel investigations between December 2013 and September 2016. Acceptability, recovery time, scan burden and willingness to repeat the test were analysed using the Wilcoxon signed rank and McNemar tests; and group differences in scan burden with Mann-Whitney U and Kruskal-Wallis tests.
Results: Overall, 128 (88%) patients rated MRE as very or fairly acceptable, lower than US (144, 99%; p<0.001), but greater than colonoscopy (60, 60%; p<0.001). MRE recovery time was longer than US (p<0.001), but shorter than colonoscopy (p<0.001). Patients were less willing to undergo MRE again than US (127 vs 133, 91% vs. 99%; p=0.012), but more willing than for colonoscopy (68, 75%; p=0.017). MRE generated greater burden than US (p<0.001), although burden scores were low. Younger age and emotional distress were associated with greater MRE and US burden. Higher MRE discomfort was associated with patient preference for US (p=0.053). Patients rated test accuracy as more important than scan discomfort.
Conclusions.: MRE and US are well tolerated. Although MRE generates greater burden, longer recovery, and is less preferred than US, it is more acceptable than colonoscopy. Patients however place greater emphasis on diagnostic accuracy than burden
Many Labs 5:Testing pre-data collection peer review as an intervention to increase replicability
Replication studies in psychological science sometimes fail to reproduce prior findings. If these studies use methods that are unfaithful to the original study or ineffective in eliciting the phenomenon of interest, then a failure to replicate may be a failure of the protocol rather than a challenge to the original finding. Formal pre-data-collection peer review by experts may address shortcomings and increase replicability rates. We selected 10 replication studies from the Reproducibility Project: Psychology (RP:P; Open Science Collaboration, 2015) for which the original authors had expressed concerns about the replication designs before data collection; only one of these studies had yielded a statistically significant effect (p < .05). Commenters suggested that lack of adherence to expert review and low-powered tests were the reasons that most of these RP:P studies failed to replicate the original effects. We revised the replication protocols and received formal peer review prior to conducting new replication studies. We administered the RP:P and revised protocols in multiple laboratories (median number of laboratories per original study = 6.5, range = 3?9; median total sample = 1,279.5, range = 276?3,512) for high-powered tests of each original finding with both protocols. Overall, following the preregistered analysis plan, we found that the revised protocols produced effect sizes similar to those of the RP:P protocols (?r = .002 or .014, depending on analytic approach). The median effect size for the revised protocols (r = .05) was similar to that of the RP:P protocols (r = .04) and the original RP:P replications (r = .11), and smaller than that of the original studies (r = .37). Analysis of the cumulative evidence across the original studies and the corresponding three replication attempts provided very precise estimates of the 10 tested effects and indicated that their effect sizes (median r = .07, range = .00?.15) were 78% smaller, on average, than the original effect sizes (median r = .37, range = .19?.50)