90 research outputs found

    Single blind randomized Phase III trial to investigate the benefit of a focal lesion ablative microboost in prostate cancer (FLAME-trial): study protocol for a randomized controlled trial

    Get PDF
    Background: The treatment results of external beam radiotherapy for intermediate and high risk prostate cancer patients are insufficient with five-year biochemical relapse rates of approximately 35%. Several randomized trials have shown that dose escalation to the entire prostate improves biochemical disease free survival. However, further dose escalation to the whole gland is limited due to an unacceptable high risk of acute and late toxicity. Moreover, local recurrences often originate at the location of the macroscopic tumor, so boosting the radiation dose at the macroscopic tumor within the prostate might increase local control. A reduction of distant metastases and improved survival can be expected by reducing local failure. The aim of this study is to investigate the benefit of an ablative microboost to the macroscopic tumor within the prostate in patients treated with external beam radiotherapy for prostate cancer.Methods/Design: The FLAME-trial (Focal Lesion Ablative Microboost in prostatE cancer) is a single blind randomized controlled phase III trial. We aim to include 566 patients (283 per treatment arm) with intermediate or high risk adenocarcinoma of the prostate who are scheduled for external beam radiotherapy using fiducial markers for position verification. With this number of patients, the expected increase in five-year freedom from biochemical failure rate of 10% can be detected with a power of 80%. Patients allocated to the standard arm receive a dose of 77 Gy in 35 fractions to the entire prostate and patients in the experimental arm receive 77 Gy to the entire prostate and an additional integrated microboost to the macroscopic tumor of 95 Gy in 35 fractions. The secondary outcome measures include treatment-related toxicity, quality of life and disease-specific survival. Furthermore, by localizing the recurrent tumors within the prostate during follow-up and correlating this with the delivered dose, we can obtain accurate dose-effect information for both the macroscopic tumor and subclinical disease in prostate cancer. The rationale, study design and the first 50 patients included are described.Biological, physical and clinical aspects of cancer treatment with ionising radiatio

    Sunlight exposure or vitamin D supplementation for vitamin D-deficient non-western immigrants: a randomized clinical trial

    Get PDF
    Summary: Vitamin D deficiency is very common in non-western immigrants. In this randomized clinical trial, vitamin D 800 IU/day or 100,000 IU/3 months were compared with advised sunlight exposure. Vitamin D supplementation was more effective than advised sunlight exposure in improving vitamin D status and lowering parathyroid hormone levels. Introduction: Vitamin D deficiency (25-hydroxyvitamin D [25(OH)D]<25 nmol/l) is common among non-western immigrants. It can be treated with vitamin D supplementation or sunlight exposure. Methods: To determine whether the effect of vitamin

    Serum 25-Hydroxyvitamin D Concentrations and Season-Specific Correlates in Japanese Adults

    Get PDF
    Background: Several lines of evidence indicate an important role for vitamin D in the prevention of a range of diseases. Blood vitamin D levels show clear seasonal variation; however, data on the determinants of vitamin D status for each season are limited. We investigated the association between lifestyle and serum vitamin D concentration by season in Japanese workers. Methods: Subjects were 312 men and 217 women aged 21 to 67 years who worked in municipal offices in Northern Kyushu, Japan and participated in a periodic checkup in July or November. Multiple linear regression analysis was used to examine the association between serum 25-hydroxivitamin D concentrations and lifestyle factors for each season. Results: Mean serum 25-hydroxyvitamin D concentration was 27.4 ng/ml (68.4 nmol/L) and 21.4 ng/ml (53.4 nmol/L) for workers surveyed in July and November, respectively (P \u3c 0.001); the prevalence of vitamin D deficiency ( both sexes) and nonsmoking and physical activity (in men) were significantly associated with higher concentrations of serum 25-hydroxyvitamin D. In summer, fish/shellfish intake was associated with higher serum 25- hydroxyvitamin D concentrations in women. Conclusions: Vitamin D deficiency is common in Japanese workers during seasons with limited sunlight. The lifestyle correlates of favorable vitamin D status in November were physical activity, dietary vitamin D intake, and nonsmoking

    Low-temperature plasma treatment induces DNA damage leading to necrotic cell death in primary prostate epithelial cells

    Get PDF
    Background:In recent years, the rapidly advancing field of low-temperature atmospheric pressure plasmas has shown considerable promise for future translational biomedical applications, including cancer therapy, through the generation of reactive oxygen and nitrogen species.Method:The cytopathic effect of low-temperature plasma was first verified in two commonly used prostate cell lines: BPH-1 and PC-3 cells. The study was then extended to analyse the effects in paired normal and tumour (Gleason grade 7) prostate epithelial cells cultured directly from patient tissue. Hydrogen peroxide (H2O2) and staurosporine were used as controls throughout.Results:Low-temperature plasma (LTP) exposure resulted in high levels of DNA damage, a reduction in cell viability, and colony-forming ability. H2O2 formed in the culture medium was a likely facilitator of these effects. Necrosis and autophagy were recorded in primary cells, whereas cell lines exhibited apoptosis and necrosis.Conclusions:This study demonstrates that LTP treatment causes cytotoxic insult in primary prostate cells, leading to rapid necrotic cell death. It also highlights the need to study primary cultures in order to gain more realistic insight into patient response

    Indentation Hardness Measurements at Macro-, Micro-, and Nanoscale: A Critical Overview

    Get PDF
    The Brinell, Vickers, Meyer, Rockwell, Shore, IHRD, Knoop, Buchholz, and nanoindentation methods used to measure the indentation hardness of materials at different scales are compared, and main issues and misconceptions in the understanding of these methods are comprehensively reviewed and discussed. Basic equations and parameters employed to calculate hardness are clearly explained, and the different international standards for each method are summarized. The limits for each scale are explored, and the different forms to calculate hardness in each method are compared and established. The influence of elasticity and plasticity of the material in each measurement method is reviewed, and the impact of the surface deformation around the indenter on hardness values is examined. The difficulties for practical conversions of hardness values measured by different methods are explained. Finally, main issues in the hardness interpretation at different scales are carefully discussed, like the influence of grain size in polycrystalline materials, indentation size effects at micro-and nanoscale, and the effect of the substrate when calculating thin films hardness. The paper improves the understanding of what hardness means and what hardness measurements imply at different scales.Funding Agencies|Swedish Government Strategic Research Area in Materials Science on Functional Materials at Linkoping University ((Faculty Grant SFO Mat LiU) [2009 00971]</p

    Real-time prostate motion assessment: image-guidance and the temporal dependence of intra-fraction motion

    Get PDF
    BACKGROUND: The rapid adoption of image-guidance in prostate intensity-modulated radiotherapy (IMRT) results in longer treatment times, which may result in larger intrafraction motion, thereby negating the advantage of image-guidance. This study aims to qualify and quantify the contribution of image-guidance to the temporal dependence of intrafraction motion during prostate IMRT. METHODS: One-hundred and forty-three patients who underwent conventional IMRT (n=67) or intensity-modulated arc therapy (IMAT/RapidArc, n=76) for localized prostate cancer were evaluated. Intrafraction motion assessment was based on continuous RL (lateral), SI (longitudinal), and AP (vertical) positional detection of electromagnetic transponders at 10 Hz. Daily motion amplitudes were reported as session mean, median, and root-mean-square (RMS) displacements. Temporal effect was evaluated by categorizing treatment sessions into 4 different classes: IMRT(c) (transponder only localization), IMRT(cc) (transponder + CBCT localization), IMAT(c) (transponder only localization), or IMAT(cc) (transponder + CBCT localization). RESULTS: Mean/median session times were 4.15/3.99 min (IMAT(c)), 12.74/12.19 min (IMAT(cc)), 5.99/5.77 min (IMRT(c)), and 12.98/12.39 min (IMRT(cc)), with significant pair-wise difference (p<0.0001) between all category combinations except for IMRT(cc) vs. IMAT(cc) (p>0.05). Median intrafraction motion difference between CBCT and non-CBCT categories strongly correlated with time for RMS (t-value=17.29; p<0.0001), SI (t-value=−4.25; p<0.0001), and AP (t-value=2.76; p<0.0066), with a weak correlation for RL (t-value=1.67; p=0.0971). Treatment time reduction with non-CBCT treatment categories showed reductions in the observed intrafraction motion: systematic error (Σ)<0.6 mm and random error (σ)<1.2 mm compared with ≤0.8 mm and <1.6 mm, respectively, for CBCT-involved treatment categories. CONCLUSIONS: For treatment durations >4-6 minutes, and without any intrafraction motion mitigation protocol in place, patient repositioning is recommended, with at least the acquisition of the lateral component of an orthogonal image pair in the absence of volumetric imaging
    corecore