3,296 research outputs found

    Current-induced domain wall motion in a nanowire with perpendicular magnetic anisotropy

    Full text link
    We study theoretically the current-induced magnetic domain wall motion in a metallic nanowire with perpendicular magnetic anisotropy. The anisotropy can reduce the critical current density of the domain wall motion. We explain the reduction mechanism and identify the maximal reduction conditions. This result facilitates both fundamental studies and device applications of the current- induced domain wall motion

    DETERMINATION OF LINEAR AND NONLINEAR ROLL DAMPING COEFFICIENTS OF A SHIP SECTION USING CFD

    Get PDF
    The most prevalently used method to obtain the nonlinear roll damping coefficient is the free roll decay test. However, this method can only be conducted at the resonance frequency and thus cannot consider the effect of the frequency. This is a certain limitation as the resonance frequency can be changed at any time by the ship’s loading conditions. Therefore, it is worth investigating the frequency dependency of the nonlinear roll damping coefficients. In this study, a numerical method was proposed to derive the linear and nonlinear roll damping coefficients of ships at different frequencies. Fully nonlinear CFD simulations of forced harmonic roll motion were conducted and the roll damping coefficients were calculated. Then, the damping coefficients were decomposed into the linear and nonlinear components using the linear regression analysis. The linear roll damping coefficients were compared with potential coefficients and showed a good agreement, while the nonlinear roll damping coefficients were compared with the coefficients calculated using a semi-empirical method. The nonlinear roll damping coefficients calculated from the proposed method showed a strong frequency dependency. Finally, possible rationales for the frequency dependence of the nonlinear roll damping coefficient were investigated

    Quantifying the environmental burdens of the hot mix asphalt (HMA) pavements and the production of warm mix asphalt (WMA)

    Get PDF
    AbstractAsphalt pavement has significant environmental burdens throughout its life cycle. A life cycle assessment (LCA) model is used to quantify the environmental burdens for material, construction, maintenance and use phases of hot mix asphalt (HMA) pavement. Two peer reviewed journals have been used to collect all of the inventory loadings as an input for the LCA model and ten impact categories have been evaluated as output. The result of the inventory analysis is a summary of all inflows and outflows related to the “functional unit”. The result of each impact category is the total of all the individually characterized inventory loadings in each category. Each life cycle phase of HMA pavement has been quantified on these ten impact categories and a comparison provided among the phases to understand the percentage contribution to the environment. Human and eco toxicity values are higher for the material phase, whereas the rest of the impact categories are significant in the use phase. The material phase contributes 97% of the overall human toxicity in water from standpoint of asphalt pavements, whereas in the material phase the production of bitumen is responsible for 90% human and eco toxicity in terms of air based burden. As a solution, the life cycle inventory of WMA has been estimated and reduction only done in HMA production. From analysis, it was estimated that WMA provides a reduction of 29% on the acidification impact and 25% reduction on both fossil fuel consumption and photo oxidant formation impact of HMA

    Monitoring of multi-frequency polarization of gamma-ray bright AGNs

    Full text link
    We started two observing programs with the Korean VLBI Network (KVN) monitoring changes in the flux density and polarization of relativistic jets in gamma-ray bright AGNs simultaneously at 22, 43, 86, 129 GHz. One is a single-dish weekly-observing program in dual polarization with KVN 21-m diameter radio telescopes beginning in 2011 May. The other is a VLBI monthly-observing program with the three-element VLBI network at an angular resolution range of 1.0--9.2 mas beginning in 2012 December. The monitoring observations aim to study correlation of variability in gamma-ray with that in radio flux density and polarization of relativistic jets when they flare up. These observations enable us to study the origin of the gamma-ray flares of AGNs.Comment: 4 pages, 4 figures, Proceedings of the conference "The innermost regions of relativistic jets and their magnetic fields", Granada, Spai

    VR/AR head-mounted display system based measurement and evaluation of dynamic visual acuity

    Get PDF
    This study evaluated the dynamic visual acuity of candidates by implementing a King–Devick (K-D) test chart in a virtual reality head-mounted display (VR HMD) and an augmented reality head-mounted display (AR HMD). Hard-copy KD (HCKD), VR HMD KD (VHKD), and AR HMD KD (AHKD) tests were conducted in 30 male and female candidates in the age of 10S and 20S and subjective symptom surveys were conducted. In the subjective symptom surveys, all except one of the VHKD questionnaire items showed subjective symptoms of less than 1 point. In the comparison between HCKD and VHKD, HCKD was measured more rapidly than VHKD in all tests. In the comparison between HCKD and AHKD, HCKD was measured more rapidly than AHKD in Tests 1, 2, and 3. In the comparison between VHKD and AHKD, AHKD was measured more rapidly than VHKD in Tests 1, 2, and 3. In the correlation analyses of test platforms, all platforms were correlated with each other, except for the correlation between HCKD and VHKD in Tests 1 and 2. There was no significant difference in the frequency of errors among Tests 1, 2, and 3 across test platforms. VHKD and AHKD, which require the body to be moved to read the chart, required longer measurement time than HCKD. In the measurements of each platform, AHKD was measured closer to HCKD than VHKD, which may be because the AHKD environment is closer to the actual environment than the VHKD environment. The effectiveness of VHKD and AHKD proposed in this research was evaluated experimentally. The results suggest that treatment and training could be performed concurrently through the use of clinical test and content development of VHKD and AHKD

    Neck control after definitive radiochemotherapy without planned neck dissection in node-positive head and neck cancers

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of this study was to evaluate neck control outcomes after definitive radiochemotherapy without planned neck dissection in node-positive head and neck cancer.</p> <p>Methods</p> <p>We retrospectively reviewed medical records of fifty patients with node-positive head and neck cancer who received definitive radiochemotherapy. Twelve patients subsequently underwent neck dissection for suspicious recurrent or persistent disease. A median dose of 70 Gy (range 60-70.6) was delivered to involved nodes. Response evaluation was performed at a median of 5 weeks after completion of radiotherapy.</p> <p>Results</p> <p>Neck failure was observed in 11 patients and the 3-year regional control (RC) rate was 77.1%. Neck dissection was performed in 10 of the 11 patients; seven of these cases were successfully salvaged, and the ultimate rate of neck control was 92%. The remaining two patients who received neck dissection had negative pathologic results. On univariate analysis, initial nodal size > 2 cm, a less-than-complete response at the primary site, post-radiotherapy nodal size > 1.5 cm, and post-radiotherapy nodal necrosis were associated with RC. On multivariate analysis, less-than-complete primary site response and post-radiotherapy nodal necrosis were identified as independent prognostic factors for RC.</p> <p>Conclusions</p> <p>The neck failure rate after definitive radiochemotherapy without planned neck dissection was 22%. Two-thirds of these were successfully salvaged with neck dissection and the ultimate neck control rate was 92%. Our results suggest that planned neck dissection might not be necessary in patients with complete response of primary site, no evidence of residual lesion > 1.5 cm, or no necrotic lymph nodes at the 1-2 months follow-up evaluation after radiotherapy.</p

    Interrupted aortic arch diagnosed with loss of femoral pulse in a patient undergoing patent ductus arteriosus ligation -A case report-

    Get PDF
    A 12-year-old boy with ventricular septal defect and patent ductus arteriosus was presented to the operating room. Upon clamping the patent ductus arteriosus, the femoral arterial pressure curve was lost; however, it returned upon unclamping. Upon further dissection, an interrupted aortic arch was found between the left subclavian artery and patent ductus arteriosus. The surgery was discontinued for further evaluation
    corecore