242 research outputs found

    Determination of band alignment in the single layer MoS2/WSe2 heterojunction

    Full text link
    The emergence of transition metal dichalcogenides (TMDs) as 2D electronic materials has stimulated proposals of novel electronic and photonic devices based on TMD heterostructures. Here we report the determination of band offsets in TMD heterostructures by using microbeam X-ray photoelectron spectroscopy ({\mu}-XPS) and scanning tunneling microscopy/spectroscopy (STM/S). We determine a type-II alignment between MoS2\textrm{MoS}_2 and WSe2\textrm{WSe}_2 with a valence band offset (VBO) value of 0.83 eV and a conduction band offset (CBO) of 0.76 eV. First-principles calculations show that in this heterostructure with dissimilar chalcogen atoms, the electronic structures of WSe2\textrm{WSe}_2 and MoS2\textrm{MoS}_2 are well retained in their respective layers due to a weak interlayer coupling. Moreover, a VBO of 0.94 eV is obtained from density functional theory (DFT), consistent with the experimental determination.Comment: ^ These authors contributed equally. *Corresponding author E-mail: [email protected], [email protected] 20 pages, 4 figures in main tex

    Real-Time Observation of Iodide Ion Migration in Methylammonium Lead Halide Perovskites

    Get PDF
    Organic-inorganic metal-halide perovskites (e.g. CH3NH3PbI3-xClx) emerged as a promising opto-electronic material. However, the Shockley–Queisser Limit for the power conversion efficiency (PCE) of perovskite-based photovoltaic devices has still not been reached, which was attributed to non-radiative recombination pathways, as suggested by photoluminescence (PL) inactive (or dark) areas on perovskite films. Although these observations have been related to the presence of ions/defects, the underlying fundamental physics and detailed microscopic processes, concerning trap/defect status, ion migration, etc., still remain poorly understood. Here we utilize correlated wide-field PL microscopy and impedance spectroscopy (IS) on perovskite films to in-situ investigate both the spatial and temporal evolution of these PL inactive areas under external electrical fields. We attribute the formation of PL inactive domains to the migration and accumulation of iodine ions under external fields. Hence we are able to characterize the kinetic processes and determine the drift velocities of these ions. In addition, we show that I2 vapor directly affects the PL quenching of a perovskite film, which provides evidence that the migration/segregation of iodide ions plays an important role in the PL quenching and consequently limits the PCE of organometal halide based perovskite photovoltaic devices

    Association of Female Menopause With Atrioventricular Mechanics and Outcomes

    Get PDF
    BACKGROUND: Despite known sex differences in cardiac structure and function, little is known about how menopause and estrogen associate with atrioventricular mechanics and outcomes. OBJECTIVE: To study how, sex differences, loss of estrogen in menopause and duration of menopause, relate to atrioventricular mechanics and outcomes. METHODS: Among 4051 asymptomatic adults (49.8 ± 10.8 years, 35%women), left ventricular (LV) and left atrial (LA) mechanics were assessed using speckle-tracking. RESULTS: Post-menopausal (vs. pre-menopausal) women had similar LV ejection fraction but reduced GLS, reduced PALS, increased LA stiffness, higher LV sphericity and LV torsion (all p < 0.001). Multivariable analysis showed menopause to be associated with greater LV sphericity (0.02, 95%CI 0.01, 0.03), higher indexed LV mass (LVMi), lower mitral e’, lower LV GLS (0.37, 95%CI 0.04–0.70), higher LV torsion, larger LA volume, worse PALS (∼2.4-fold) and greater LA stiffness (0.028, 95%CI 0.01–0.05). Increasing years of menopause was associated with further reduction in GLS, markedly worse LA mechanics despite greater LV sphericity and higher torsion. Lower estradiol levels correlated with more impaired LV diastolic function, impaired LV GLS, greater LA stiffness, and increased LV sphericity and LV torsion (all p < 0.05). Approximately 5.5% (37/669) of post-menopausal women incident HF over 2.9 years of follow-up. Greater LV sphericity [adjusted hazard ratio (aHR) 1.04, 95%CI 1.00–1.07], impaired GLS (aHR 0.87, 95%CI 0.78–0.97), reduced peak left atrial longitudinal strain (PALS, aHR 0.94, 95%CI 0.90–0.99) and higher LA stiffness (aHR 10.5, 95%CI 1.69–64.6) were independently associated with the primary outcome of HF hospitalizations in post-menopause. Both PALS < 23% (aHR:1.32, 95%CI 1.01–3.49) and GLS < 16% (aHR:5.80, 95%CI 1.79–18.8) remained prognostic for the incidence of HF in post-menopausal women in dichotomous analyses, even after adjusting for confounders. Results were consistent with composite outcomes of HF hospitalizations and 1-year all-cause mortality as well. CONCLUSION: Menopause was associated with greater LV/LA remodeling and reduced LV longitudinal and LA function in women. The cardiac functional deficit with menopause and lower estradiol levels, along with their independent prognostic value post-menopause, may elucidate sex differences in heart failure further

    Potential of Core-Collapse Supernova Neutrino Detection at JUNO

    Get PDF
    JUNO is an underground neutrino observatory under construction in Jiangmen, China. It uses 20kton liquid scintillator as target, which enables it to detect supernova burst neutrinos of a large statistics for the next galactic core-collapse supernova (CCSN) and also pre-supernova neutrinos from the nearby CCSN progenitors. All flavors of supernova burst neutrinos can be detected by JUNO via several interaction channels, including inverse beta decay, elastic scattering on electron and proton, interactions on C12 nuclei, etc. This retains the possibility for JUNO to reconstruct the energy spectra of supernova burst neutrinos of all flavors. The real time monitoring systems based on FPGA and DAQ are under development in JUNO, which allow prompt alert and trigger-less data acquisition of CCSN events. The alert performances of both monitoring systems have been thoroughly studied using simulations. Moreover, once a CCSN is tagged, the system can give fast characterizations, such as directionality and light curve

    Detection of the Diffuse Supernova Neutrino Background with JUNO

    Get PDF
    As an underground multi-purpose neutrino detector with 20 kton liquid scintillator, Jiangmen Underground Neutrino Observatory (JUNO) is competitive with and complementary to the water-Cherenkov detectors on the search for the diffuse supernova neutrino background (DSNB). Typical supernova models predict 2-4 events per year within the optimal observation window in the JUNO detector. The dominant background is from the neutral-current (NC) interaction of atmospheric neutrinos with 12C nuclei, which surpasses the DSNB by more than one order of magnitude. We evaluated the systematic uncertainty of NC background from the spread of a variety of data-driven models and further developed a method to determine NC background within 15\% with {\it{in}} {\it{situ}} measurements after ten years of running. Besides, the NC-like backgrounds can be effectively suppressed by the intrinsic pulse-shape discrimination (PSD) capabilities of liquid scintillators. In this talk, I will present in detail the improvements on NC background uncertainty evaluation, PSD discriminator development, and finally, the potential of DSNB sensitivity in JUNO

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data
    corecore