485 research outputs found
Application of Artificial Neural Network to Search for Gravitational-Wave Signals Associated with Short Gamma-Ray Bursts
We apply a machine learning algorithm, the artificial neural network, to the
search for gravitational-wave signals associated with short gamma-ray bursts.
The multi-dimensional samples consisting of data corresponding to the
statistical and physical quantities from the coherent search pipeline are fed
into the artificial neural network to distinguish simulated gravitational-wave
signals from background noise artifacts. Our result shows that the data
classification efficiency at a fixed false alarm probability is improved by the
artificial neural network in comparison to the conventional detection
statistic. Therefore, this algorithm increases the distance at which a
gravitational-wave signal could be observed in coincidence with a gamma-ray
burst. In order to demonstrate the performance, we also evaluate a few seconds
of gravitational-wave data segment using the trained networks and obtain the
false alarm probability. We suggest that the artificial neural network can be a
complementary method to the conventional detection statistic for identifying
gravitational-wave signals related to the short gamma-ray bursts.Comment: 30 pages, 10 figure
Recommended from our members
Elevated cellular cholesterol in Familial Alzheimerâs presenilin 1 mutation is associated with lipid raft localization of ÎČ-amyloid precursor protein
Familial Alzheimerâs disease (FAD)-associated presenilin 1 (PS1) serves as a catalytic subunit of Îł-secretase complex, which mediates the proteolytic liberation of ÎČ-amyloid (AÎČ) from ÎČ-amyloid precursor protein (APP). In addition to its proteolytic role, PS1 is involved in non-proteolytic functions such as protein trafficking and ion channel regulation. Furthermore, postmortem AD brains as well as AD patients showed dysregulation of cholesterol metabolism. Since cholesterol has been implicated in regulating AÎČ production, we investigated whether the FAD PS1-associated cholesterol elevation could influence APP processing. We found that in CHO cells stably expressing FAD-associated PS1 ÎE9, total cholesterol levels are elevated compared to cells expressing wild-type PS1. We also found that localization of APP in cholesterol-enriched lipid rafts is substantially increased in the mutant cells. Reducing the cholesterol levels by either methyl-ÎČ-cyclodextrin or an inhibitor of CYP51, an enzyme mediating the elevated cholesterol in PS1 ÎE9-expressing cells, significantly reduced lipid raft-associated APP. In contrast, exogenous cholesterol increased lipid raft-associated APP. These data suggest that in the FAD PS1 ÎE9 cells, the elevated cellular cholesterol level contributes to the altered APP processing by increasing APP localized in lipid rafts
Effects of a radiation dose reduction strategy for computed tomography in severely injured trauma patients in the emergency department: an observational study
<p>Abstract</p> <p>Background</p> <p>Severely injured trauma patients are exposed to clinically significant radiation doses from computed tomography (CT) imaging in the emergency department. Moreover, this radiation exposure is associated with an increased risk of cancer. The purpose of this study was to determine some effects of a radiation dose reduction strategy for CT in severely injured trauma patients in the emergency department.</p> <p>Methods</p> <p>We implemented the radiation dose reduction strategy in May 2009. A prospective observational study design was used to collect data from patients who met the inclusion criteria during this one year study (intervention group) from May 2009 to April 2010. The prospective data were compared with data collected retrospectively for one year prior to the implementation of the radiation dose reduction strategy (control group). By comparison of the cumulative effective dose and the number of CT examinations in the two groups, we evaluated effects of a radiation dose reduction strategy. All the patients met the institutional adult trauma team activation criteria. The radiation doses calculated by the CT scanner were converted to effective doses by multiplication by a conversion coefficient.</p> <p>Results</p> <p>A total of 118 patients were included in this study. Among them, 33 were admitted before May 2009 (control group), and 85 were admitted after May 2009 (intervention group). There were no significant differences between the two groups regarding baseline characteristics, such as injury severity and mortality. Additionally, there was no difference between the two groups in the mean number of total CT examinations per patient (4.8 vs. 4.5, respectively; p = 0.227). However, the mean effective dose of the total CT examinations per patient significantly decreased from 78.71 mSv to 29.50 mSv (p < 0.001).</p> <p>Conclusions</p> <p>The radiation dose reduction strategy for CT in severely injured trauma patients effectively decreased the cumulative effective dose of the total CT examinations in the emergency department. But not effectively decreased the number of CT examinations.</p
Multislice Bâ Mapping Method Using Magnetic Resonance Composite Spin Echo Sequences and Simultaneous Echo Refocusing
Radiofrequency (RF) transmit field (B1) mapping is a promising method in mitigating the B1 inhomogeneity in various magnetic resonance imaging (MRI) applications. Although several phase- or magnitude-based B1 mapping methods have been proposed, these methods often require complex modeling, long acquisition time, or specialized MRI sequences. A recently introduced simultaneous echo refocusing (SER) technique can be applied in the B1 mapping method to extend the three-dimensional (3D) spatial coverage only without long data acquisition. Therefore, in this study, a multislice B1 mapping method using composite spin echo sequences and SER techniques is proposed to obtain more accurate B1 mapping with short data acquisition time. To evaluate the performance of the proposed B1 mapping method, computational simulations were performed and compared with Morrellâs method, double angle method, and Yarnykhâs method. These results showed that the angle-to-noise ratio of the proposed B1 mapping method has wider B1 range compared to that of other B1 mapping methods. In addition, the proposed B1 mapping methods were compared to the multislice iterative signal intensity mapping method in both phantom and in vivo human experiments, and there was no remarkable difference between the two methods regarding the flip angle distribution in these experiments. Based on these results, this study demonstrated that the proposed B1 mapping method is suitable for accurately measuring B1 propagation under the condition providing reduced scan time and wider 3D coverage of B1 mapping by applying composite RF pulse and SER techniques into the phase-sensitive method
Correlation of hypoxia inducible transcription factor in breast cancer and SUVmax of F-18 FDG PET/CT
BACKGROUND: Tumor hypoxia induces the expression of several genes via the hypoxia-inducible transcription factor-1 alpha (HIF-1a). It is associated with the prognosis of several cancers. We studied the immunohistochemical expression of HIF-1a in patients with invasive ductal cancer (IDC) of the breast and the possible correlation with the maximum standardized uptake value of the primary tumor (pSUVmax) as well as other biological parameters. Prognostic significance of pSUVmax and expression of HIF-1a for the prediction of progression-free survival (PFS) was also assessed.
MATERIAL AND METHODS: Two-hundred seven female patients with IDC who underwent pretreatment fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) were enrolled. The pSUVmax was compared with clinicopathological parameters including estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor receptor 2 (HER2), axillary lymph node (LN) metastasis, stage and HIF-1a expression. The prognostic value of pSUVmax for PFS was assessed using the Kaplan-Meier method.
RESULTS: pSUVmax was significantly higher in patients with HIF-1a expression ℠2 compared to patients with HIF-1a expression < 2 (5.2 ± 4.5 vs. 3.7 ± 3.1, p = 0.008). pSUVmax was also significantly higher in higher stage (p < 0.000001), ER-negative tumors (p < 0.0001), PR-negative tumors (p = 0.0011) and positive LN metastasis (p = 0.0013). pSUVmax was significantly higher in patients with progression compared to patients who were disease-free (6.8 ± 4.4 vs. 4.1 ± 3.7, p = 0.0005). A receiver-operating characteristic curve demonstrated a pSUVmax of 6.51 to be the optimal cutoff for predicting PFS (sensitivity: 53.6%, specificity: 86.0%). Patients with high pSUVmax (> 6.5) had significantly shorter PFS compared to patients with low pSUVmax (p < 0.0001).
CONCLUSIONS: pSUVmax on pretreatment F-18 FDG PET/ CT reflect expression of HIF-1a and can be used as a good surrogate marker for the prediction of progression in patients with IDC. The amount of FDG uptake is determined by the presence of glucose metabolism and hypoxia in breast cancer cell
The appropriateness of single page of activation of the cardiac catheterization laboratory by emergency physician for patients with suspected ST-segment elevation myocardial infarction: a cohort study
<p>Abstract</p> <p>Background</p> <p>The early use of reperfusion therapy has a significant effect on the prognosis of patients with ST-segment elevation myocardial infarction (STEMI), and it is recommended that emergency department (ED) physicians activate the cardiac catheterization laboratory (CCL) as soon as possible to treat these patients. The aim of this study was to examine the appropriateness of emergency physician activation of the CCL for patients with suspected STEMI. Inappropriate activations (i.e., false positive activations) were identified according to a variety of criteria.</p> <p>Methods</p> <p>All patients with emergency physician CCL activations between August 2009 and April 2011 were included in the study. False positive cases were defined according to ECG criteria and cardiologists' reviews of patients' initial clinical information.</p> <p>Results</p> <p>ED physicians used a STEMI page to activate the CCL 117 times. According to reviews by cardiologists, this activation was appropriate 89.8% of the time (in 105/117 cases). Truly unnecessary activation (i.e., cases in which STEMI was not identified by the cardiologists, no clear culprit coronary artery was present, no significant coronary artery disease and cardiac biomarkers were negative) occurred 5.1% of the time (in 6/117 cases).</p> <p>Conclusions</p> <p>CCL activation was appropriate for most patients and was unnecessary in a relatively small percentage of cases. This result supports the current recommendation for CCL activation by emergency physicians. Such early activation is a key strategy in the reduction of door-to-balloon time.</p
The validity of the canadian triage and acuity scale in predicting resource utilization and the need for immediate life-saving interventions in elderly emergency department patients
<p>Abstract</p> <p>Background</p> <p>We evaluated the validity of the Canadian Triage and Acuity Scale (CTAS) in elderly emergency department (ED) patients. In particular, we examined the sensitivity and specificity of the CTAS for identifying elderly patients who received an immediate life-saving intervention in the ED.</p> <p>Methods</p> <p>We reviewed the medical records of consecutive patients who were 65 years of age or older and presented to a single academic ED within a three-month period. The CTAS triage scores were compared to actual patient course, including disposition, discharge outcome and resource utilization. We calculated the sensitivity and specificity of the CTAS triage for identifying patients who received an immediate intervention.</p> <p>Results</p> <p>Of the 1903 consecutive patients who were ℠65 years of age, 113 (5.9%) had a CTAS level of 1, 174 (9.1%) had a CTAS level of 2, 1154 (60.6%) had a CTAS level of 3, 347 (18.2%) had a CTAS level of 4, and 115 (6.0%) had a CTAS level of 5. As a patient's triage score increased, the severity (such as mortality and intensive care unit admission) and resource utilization increased significantly. Ninety-four of the patients received a life-saving intervention within an hour following their arrival to the ED. The CTAS scores for these patients were 1, 2 and 3 for 46, 46 and 2 patients, respectively. The sensitivity and specificity of a CTAS score of †2 for identifying patients for receiving an immediate intervention were 97.9% and 89.2%, respectively.</p> <p>Conclusions</p> <p>The CTAS is a triage tool with high validity for elderly patients, and it is an especially useful tool for categorizing severity and for recognizing elderly patients who require immediate life-saving intervention.</p
Thermal analysis of bulk filled composite resin polymerization using various light curing modes according to the curing depth and approximation to the cavity wall
OBJECTIVE: The purpose of this study was to investigate the polymerization temperature of a bulk filled composite resin light-activated with various light curing modes using infrared thermography according to the curing depth and approximation to the cavity wall. MATERIAL AND METHODS: Composite resin (AeliteFlo, Bisco, Schaumburg, IL, USA) was inserted into a Class II cavity prepared in the Teflon blocks and was cured with a LED light curing unit (Dr's Light, GoodDoctors Co., Seoul, Korea) using various light curing modes for 20 s. Polymerization temperature was measured with an infrared thermographic camera (Thermovision 900 SW/TE, Agema Infra-red Systems AB, Danderyd, Sweden) for 40 s at measurement spots adjacent to the cavity wall and in the middle of the cavity from the surface to a 4 mm depth. Data were analyzed according to the light curing modes with one-way ANOVA, and according to curing depth and approximation to the cavity wall with two-way ANOVA. RESULTS: The peak polymerization temperature of the composite resin was not affected by the light curing modes. According to the curing depth, the peak polymerization temperature at the depth of 1 mm to 3 mm was significantly higher than that at the depth of 4 mm, and on the surface. The peak polymerization temperature of the spots in the middle of the cavity was higher than that measured in spots adjacent to the cavity wall. CONCLUSION: In the photopolymerization of the composite resin, the temperature was higher in the middle of the cavity compared to the outer surface or at the internal walls of the prepared cavity
- âŠ