992 research outputs found
Foreign body ingestion in children presenting to a tertiary paediatric centre in South Africa: A retrospective analysis focusing on battery ingestion
Background. Ingestion of foreign bodies remains a frequent reason for presentation to paediatric emergency departments worldwide. Among the variety of objects ingested, button batteries are particularly harmful owing to their electrochemical properties, which can cause extensive injuries if not diagnosed and treated rapidly. International trends show an increasing incidence of button battery ingestion, leading to concern that this pattern may be occurring in South Africa. Limited local data on paediatric foreign body ingestion have been published.Objectives. To assess battery ingestion rates in a tertiary paediatric hospital. We hypothesised that the incidence has increased, in keeping with international trends. Secondary objectives included describing admission rates, requirements for anaesthesia and surgery, and promoting awareness of the problems associated with battery ingestion.Methods. We performed a retrospective, descriptive analysis of the Red Cross War Memorial Children’s Hospital trauma database, including all children under 13 years of age seen between 1 January 2010 and 31 December 2015 with suspected ingestion of a foreign body. The ward admissions database was then examined to find additional cases in which children were admitted directly. After exclusion of duplicate records, cases were classified by type of foreign body, management, requirement for admission, anaesthesia and surgery. Descriptive statistics were used to analyse the data in comparison with previous studies published from this database.Results. Patient age and gender patterns matched the literature, with a peak incidence in children under 2 years of age. Over the 6-year period, 180 patients presented with food foreign bodies, whereas 497 objects were classified as non-food. After exclusion of misdiagnosed cases, the remaining 462 objects were dominated by coins (44.2%). Batteries were the causative agent in 4.8% (22/462). Although the subtypes of batteries were not reliably recorded, button batteries accounted for at least 64% (14/22). Most children who ingested batteries presented early, but more required admission, anaesthesia and surgery than children who ingested other forms of foreign body.Conclusions. The study demonstrated that the local incidence of button battery ingestion may be increasing, although data are still limited.Admission, anaesthesia and surgery rates for batteries were higher in this cohort than for all other foreign bodies. As button batteries can mimic coins, with much more dire consequences on ingestion, our ability to expedite diagnosis and management hinges on a high index of suspicion. It is imperative to increase awareness among healthcare workers and parents
Calcium supplementation to prevent pre-eclampsia - a systematic review
Background. Calcium supplementation during pregnancy may prevent high blood pressure and preterm labour.
Objective. To assess the effects of calcium supplementation during pregnancy on hypertensive disorders of pregnancy and related maternal and child adverse outcomes.
Design. A systematic review of randomised trials that compared supplementation with at least 1 g calcium daily during pregnancy with placebo.
Search strategy. The Cochrane Pregnancy and Childbirth Group trials register (October 2001) and the Cochrane Controlled Trials Register (Issue 3, 2001) were searched and study s were contacted.
Data collection and analysis. Eligibility and trial quality were assessed. Data were extracted and analysed.
Main results. There was a modest reduction in the risk of pre-eclampsia with calcium supplementation (relative risk (RR) 0.68, 95% confidence interval (CI): 0.57- 0.81). The effect was greatest for women at high risk of hypertension (RR 0.21, 95% CI: 0.11 - 0.39) and those with low baseline calcium intake (RR 0.32, 95% CI: 0.21 - 0.49). There was no overall effect on the risk of preterm delivery, although there was a reduction in risk among women at high risk of hypertension (RR 0.42, 95% CI: 0.23 - 0.78). There was no evidence of any effect of calcium supplementation on stillbirth or death before discharge from hospital. There were fewer babies with birthweight 95th percentile was reduced (RR 0.59, 95% CI: 0.39 - 0.91).
Conclusions. Calcium supplementation appears to be beneficial for women at high risk of gestational hypertension and in communities with low dietary calcium intake. These benefits were confined to several rather small trials, and were not found in the largest trial to date, conducted in a low-risk population. Further research is required.
(South African Medical Journal: 2003 93(3): 224-228
Comparison of System Call Representations for Intrusion Detection
Over the years, artificial neural networks have been applied successfully in
many areas including IT security. Yet, neural networks can only process
continuous input data. This is particularly challenging for security-related
non-continuous data like system calls. This work focuses on four different
options to preprocess sequences of system calls so that they can be processed
by neural networks. These input options are based on one-hot encoding and
learning word2vec or GloVe representations of system calls. As an additional
option, we analyze if the mapping of system calls to their respective kernel
modules is an adequate generalization step for (a) replacing system calls or
(b) enhancing system call data with additional information regarding their
context. However, when performing such preprocessing steps it is important to
ensure that no relevant information is lost during the process. The overall
objective of system call based intrusion detection is to categorize sequences
of system calls as benign or malicious behavior. Therefore, this scenario is
used to evaluate the different input options as a classification task. The
results show, that each of the four different methods is a valid option when
preprocessing input data, but the use of kernel modules only is not recommended
because too much information is being lost during the mapping process.Comment: 12 pages, 1 figure, submitted to CISIS 201
Recommended from our members
UPC++ v1.0 Programmer’s Guide, Revision 2020.3.0
UPC++ is a C++11 library that provides Partitioned Global Address Space (PGAS) programming. It is designed for writing parallel programs that run efficiently and scale well on distributed-memory parallel computers. The PGAS model is single program, multiple-data (SPMD), with each separate constituent process having access to local memory as it would in C++. However, PGAS also provides access to a global address space, which is allocated in shared segments that are distributed over the processes. UPC++ provides numerous methods for accessing and using global memory. In UPC++, all operations that access remote memory are explicit, which encourages programmers to be aware of the cost of communication and data movement. Moreover, all remote-memory access operations are by default asynchronous, to enable programmers to write code that scales well even on hundreds of thousands of cores
Effects of the copper intrauterine device versus injectable progestin contraception on pregnancy rates and method discontinuation among women attending termination of pregnancy services in South Africa: a pragmatic randomized controlled trial
Background: The copper intrauterine device (IUD) is under-utilised in South Africa, where injectable progestin contraception (IPC) dominates contraception usage. There is a lack of robust comparative data on these contraceptive options to inform policy, programs, clinical counseling, and women’s choices.
Methods: Within the context of a South African program to increase women’s access to the IUD, we conducted a pragmatic, open-label, parallel-arm, randomised controlled trial of the IUD versus IPC at two South African hospitals. The target sample size was 7,000 women and the randomisation ratio was 1:1. The random sequence was computer-generated and group allocation was concealed in sealed, opaque, consecutively-numbered envelopes. Counselled, consenting women attending termination of pregnancy services were randomly assigned to IUD or IPC immediately post-termination. Condoms were promoted for the prevention of sexually-transmitted infections. The primary outcome was pregnancy; secondary outcomes were discontinuation, side-effects, and HIV acquisition and disease progression. Pregnancy and discontinuation outcomes are reported here.
Results: The trial closed early with 2,493 participants randomised (IUD = 1,247, IPC = 1,246), due to international concerns regarding a possible association between IPC and HIV acquisition. Median follow-up was 20 months; 982 and 1000 participants were followed up in the IUD and IPC groups, respectively. Baseline group characteristics were comparable. Pregnancy occurred significantly less frequently among women allocated to the IUD than IPC: 56/971 (5.8 %) versus 83/992 (8.4 %), respectively; risk ratio (RR) 0.69, 95 % confidence interval (CI) 0.50 to 0.96; P = 0.025. There were more protocol violations in the IUD group; however, discontinuation rates were similar between IUD and IPC groups (141/855 [16.5 %] and 143/974 [14.7 %], respectively). Women in the IUD group were more likely to discontinue contraceptive use due to abdominal pain or backache and non-specific symptoms, and those in the IPC group due to oligo- or amenorhoea and lack of sexual activity.
Conclusions: The IUD was significantly more effective in preventing pregnancy than IPC. Efforts to expand contraception options and improve access to the IUD in settings where it is under-utilised are worthwhile. This trial shows that randomising long-acting, reversible contraceptives is feasible.
Trial registration: Pan African Clinical Trials Registry number PACTR201409000880157 (04-09-2014)
Effects of injectable progestogen contraception versus the copper intrauterine device on HIV acquisition: sub-study of a pragmatic randomised controlled trial
Background: Evidence from observational studies suggests an increased risk of HIV acquisition among women using depot medroxyprogesterone acetate (DMPA) contraception. Methods: Within the context of a South African programme to increase women\u27s access to the intrauterine contraceptive device (IUD), we conducted a pragmatic, open-label, parallel-arm, randomised controlled trial (RCT) of the IUD versus injectable progestogen contraception (IPC) at two South African hospitals. The primary outcome was pregnancy; secondary outcomes included HIV acquisition. Consenting women attending termination of pregnancy services were randomised after pregnancy termination between July 2009 and November 2012. Condoms were promoted for the prevention of sexually transmitted infections. Voluntary HIV testing was offered at baseline and at 12 or more months later. Findings on HIV acquisition are reported in this article. Results: HIV acquisition data were available for 1290 initially HIV-negative women who underwent a final study interview at a median of 20 months after randomisation to IPC or an IUD. Baseline group characteristics were comparable. In the IPC group, 545/656 (83%) of participants received DMPA, 96 (15%) received injectable norethisterone enanthate, 14 (2%) received the IUD and one received oral contraception. In the IUD group 609 (96%) received the IUD, 20 (3%) received IPC and 5 (1%) had missing data. According to intention-to-treat analysis, HIV acquisition occurred in 20/656 (3.0%) women in the IPC arm and 22/634 (3.5%) women in the IUD arm (IPC vs IUD, risk ratio 0.88; 95% confidence interval 0.48–1.59; p=0.7). Conclusions: This sub-study was underpowered to rule out moderate differences in HIV risk, but confirms the feasibility of randomised trial methodology to address this question. Larger RCTs are needed to determine the relative risks of various contraceptive methods on HIV acquisition with greater precision
Do high fetal catecholamine levels affect heart rate variability and tneconiutn passage during labour?
Objectives. To deternrine the relationship between Umbilical arterial catecholamine levels and fetal heart rate variability and meconium passage.Study design. A prospective descriptive study was perfonned. Umbilical artery catecholamine levels were measured in 55 newborns and correlated with fetal heart rate before delivery, Umbilical arterial pH, base excess and the presence of meconum-stained liquor.Results and conclusion. The range of catecholanrine levels was enonnous, with very high epinephrine or norepinephrine levels in several fetuses. We were unable to demonstrate an association between high catecholamine levels and the presence of nonnal fetal heart rate variability despite acidaemia. We postulate that high catecholamine levels may inhibit fetal meconiUITl passage
Breast-feeding: Current knowledge, attitudes and practices of paediatricians and obstetricians
Doctors, as part of the healthcare team, can have a significant impact on the successful initiation and maintenance of breastfeeding. There is a need for ongoing education and intervention programmes to update current knowledge on breastfeeding management
- …