2,070 research outputs found

    Access to and clinical use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European Society of Cardiology Countries: 2016 Report from the European Heart Rhythm Association.

    Get PDF
    AIMS: The aim of this analysis was to provide comprehensive information on the access to and use of cardiac implantable electronic device (CIED) and catheter ablation therapy in the European Society of Cardiology (ESC) area. METHODS AND RESULTS: The European Heart Rhythm Association (EHRA) has been collecting descriptive and quantitative data on invasive arrhythmia therapies since 2008. This year 50 of the 56 ESC member countries provided data for the EHRA White Book. Up-to-date information on procedure rates for the last 5 years together with information on demographics, economy, vital statistics, local healthcare systems, and training activities is presented for each country and the 5 geographical ESC regions. Our analysis indicated that considerable heterogeneity in the access to arrhythmia therapies still exists across the ESC area. In 2015, the CIED implantation rates per million population were highest in the Western followed by the Southern and Northern European countries. The catheter ablation activity was largest in the Western followed by the Northern and Southern areas. Overall, the procedure rates were 3-10 times higher in the European than in the non-European ESC countries. Economic resources were not the only driver for utilization of arrhythmia therapies as in some Eastern European countries with relative low gross domestic product the procedure rates exceeded the average values. CONCLUSION: These data will help the healthcare professionals and stakeholders to identify and to understand in more depth the trends, disparities, and gaps in cardiac arrhythmia care and thereby promote harmonization of cardiac arrhythmias therapies in the ESC area

    Quarterly vs. yearly clinical follow-up of remotely monitored recipients of prophylactic implantable cardioverter-defibrillators: results of the REFORM trial

    Get PDF
    Aims The rapidly increasing number of patients with implantable cardioverter-defibrillators (ICD) places a large burden on follow-up providers. This study investigated the possibility of longer in-office follow-up intervals in primary prevention ICD patients under remote monitoring with automatic daily data transmissions from the implant memory. Methods and results Conducted in 155 ICD recipients with MADIT II indications, the study compared the burden of scheduled and unscheduled ICD follow-up visits, quality of life (SF-36), and clinical outcomes in patients randomized to either 3- or 12-month follow-up intervals in the period between 3 and 27 months after implantation. Remote monitoring (Biotronik Home Monitoring) was used equally in all patients. In contrast to previous clinical studies, no calendar-based remote data checks were performed between scheduled in-office visits. Compared with the 3-month follow-up interval, the 12-month interval resulted in a minor increase in the number of unscheduled follow-ups (0.64 vs. 0.27 per patient-year; P = 0.03) and in a major reduction in the total number of in-office ICD follow-ups (1.60 vs. 3.85 per patient-year; P < 0.001). No significant difference was found in mortality, hospitalization rate, or hospitalization length during the 2-year observation period, but more patients were lost to follow-up in the 12-month group (10 vs. 3; P = 0.04). The SF-36 scores favoured the 12-month intervals in the domains ‘social functioning' and ‘mental health'. Conclusion In prophylactic ICD recipients under automatic daily remote monitoring, the extension of the 3-month in-office follow-up interval to 12 months appeared to safely reduce the ICD follow-up burden during 27 months after implantation. ClinicalTrials.gov Identifier NCT00401466 (http://www.clinicaltrials.gov/ct2/show/NCT00401466

    Implantable devices for heart failure monitoring: the CardioMEMS™ system.

    Get PDF
    Several devices have been developed for heart failure (HF) treatment and monitoring. Among device-based monitoring tools, CardioMEMS™ has received growing research attention. This document reflects the key points of an ESC consensus meeting on implantable devices for monitoring in HF, with a particular focus on CardioMEMS™

    Treatment with higher dosages of heart failure medication is associated with improved outcome following cardiac resynchronization therapy

    Get PDF
    Background Cardiac resynchronization therapy (CRT) is associated with improved morbidity and mortality in patients with chronic heart failure (CHF) on optimal medical therapy. The impact of CHF medication optimization following CRT, however, has never been comprehensively evaluated. In the current study, we therefore investigated the effect of CHF medication dosage on morbidity and mortality in CHF patients after CRT implantation. Methods and results Chronic heart failure medication was assessed in 185 patients after CRT implantation. During an overall mean follow-up of 44.6 months, 83 patients experienced a primary endpoint (death, heart transplantation, assist device implantation, or hospitalization for CHF). Treatment with higher dosages of angiotensin-converting enzyme inhibitor (ACE-I) or angiotensin receptor blockers (ARBs) (P = 0.001) and beta-blockers (P < 0.001) as well as with lower dosages of loop diuretics (P < 0.001) was associated with a reduced risk for the primary combined endpoint as well as for all-cause mortality. Echocardiographic super-responders to CRT were treated with higher average dosages of ACE-I/ARBs (68.1 vs. 52.4%, P < 0.01) and beta-blockers (59 vs. 42.2%, P < 0.01). During follow-up, the average dosage of loop diuretics was decreased by 20% in super-responders, but increased by 30% in non-super-responders (P < 0.03). Conclusion The use of higher dosages of neurohormonal blockers and lower dosages of diuretics is associated with reduced morbidity and mortality following CRT implantation. Our data imply a beneficial effect of increasing neurohormonal blockade whenever possible following CRT implantatio

    EuroEco (European Health Economic Trial on Home Monitoring in ICD Patients): a provider perspective in five European countries on costs and net financial impact of follow-up with or without remote monitoring

    Get PDF
    Aim: Remote follow-up (FU) of implantable cardiac defibrillators (ICDs) allows for fewer in-office visits in combination with earlier detection of relevant findings. Its implementation requires investment and reorganization of care. Providers (physicians or hospitals) are unsure about the financial impact. The primary end-point of this randomized prospective multicentre health economic trial was the total FU-related cost for providers, comparing Home Monitoring facilitated FU (HM ON) to regular in-office FU (HM OFF) during the first 2 years after ICD implantation. Also the net financial impact on providers (taking national reimbursement into account) and costs from a healthcare payer perspective were evaluated. Methods and results: Atotal of 312 patients with VVI-or DDD-ICD implants from 17 centres in six EU countries were randomised to HMON or OFF, of which 303 were eligible for data analysis. For all contacts (in-office, calendar-or alert-triggered web-based review, discussions, calls) time-expenditure was tracked. Country-specific cost parameters were used to convert resource use into monetary values. Remote FU equipment itself was not included in the cost calculations. Given only two patients from Finland (one in each group) a monetary valuation analysis was not performed for Finland. Average age was 62.4 +/- 13.1 years, 81% were male, 39% received a DDD system, and 51% had a prophylactic ICD. Resource use with HM ON was clearly different: less FU visits (3.79 +/- 1.67 vs. 5.53 +/- 2.32; P < 0.001) despite a small increase of unscheduled visits (0.95 +/- 1.50 vs. 0.62 +/- 1.25; P < 0.005), more non-office-based contacts (1.95+3.29 vs. 1.01 +/- 2.64; P < 0.001), more Internet sessions (11.02 +/- 15.28 vs. 0.06 +/- 0.31; P < 0.001) and more in-clinic discussions (1.84 +/- 4.20 vs. 1.28 +/- 2.92; P < 0.03), but with numerically fewer hospitalizations (0.67 +/- 1.18 vs. 0.85 +/- 1.43, P = 0.23) and shorter length-of-stay (6.31 +/- 15.5 vs. 8.26 +/- 18.6; P = 0.27), although not significant. For the whole study population, the total FU cost for providers was not different for HM ON vs. OFF [mean (95% CI): (sic)204 169-238) vs. (sic)213 (182-243); range for difference ((sic)-36 to 54), NS]. From a payer perspective, FU-related costs were similar while the total cost per patient (including other physician visits, examinations, and hospitalizations) was numerically (but not significantly) lower. There was no difference in the net financial impact on providers [profit of (sic)408 (327-489) vs. (sic)400 (345-455); range for difference ((sic)-104 to 88), NS], but there was heterogeneity among countries, with less profit for providers in the absence of specific remote FU reimbursement (Belgium, Spain, and the Netherlands) and maintained or increased profit in cases where such reimbursement exists (Germany and UK). Quality of life (SF-36) was not different. Conclusion: For all the patients as a whole, FU-related costs for providers are not different for remote FU vs. purely in-office FU, despite reorganized care. However, disparity in the impact on provider budget among different countries illustrates the need for proper reimbursement to ensure effective remote FU implementation

    Serum levels of fibroblast growth factor-21 are increased in chronic and acute renal dysfunction

    Get PDF
    The progressively increasing prevalence of the Metabolic Syndrome (MetS) has emerged as a major global health concern since the MetS is associated with an increased risk for cardiovascular morbidity and mortality. Central obesity represents a key feature of the MetS and is strongly related to all MetS comorbidities. Dysregulation of adipose tissue-derived proteins, so called adipokines, has been implied to partially contribute to these effects. Recently, fibroblast growth factor-21 (FGF-21) has been introduced as a novel insulin sensitizing and weight reducing adipokine with potential therapeutic properties. However, data on FGF-21 elimination are rather limited. Therefore, FGF-21 regulation in relation to renal function has been investigated in a patient population with chronic kidney disease (CKD, study population 1), as well as one with acute kidney impairment (study population 2). In study population 1 (n = 499), patients were distributed into five CKD subgroups according to estimated glomerular filtration rate (eGFR). Median FGF-21 serum concentrations progressively increased from CKD stage 1 to stage 5 and highest values of FGF-21 were detected in stage 5 (1: 86.4 ng/l; 2: 206.4 ng/l; 3: 289.8 ng/l; 4: 591.3 ng/l; 5: 1918.1 ng/l). Furthermore, eGFR remained the strongest predictor for FGF-21 levels in multivariate analysis. For study population 2 (n = 32), blood samples were obtained before elective unilateral partial or total nephrectomy, as well as within 30 hours after surgery. In this population FGF-21 levels significantly increased after surgery (325.0 ng/l) as compared to before surgery (255.5 ng/l). Furthermore, relative changes of FGF-21 were independently and positively predicted by relative changes of creatinine in this cohort. These results are in accordance with the hypothesis that FGF-21 is eliminated by the kidneys and that the extent of kidney dysfunction substantially contributes to serum FGF-21 levels. However, additional animal experiments and prospective clinical studies are needed to further elucidate the role of the kidneys in FGF-21 physiology

    European Cardiac Resynchronization Therapy Survey II: rationale and design

    Get PDF
    The Cardiac Resynchronization Therapy (CRT) Survey II is a 6 months snapshot survey initiated by two ESC Associations, the European Heart Rhythm Association and the Heart Failure Association, which is designed to describe clinical practice regarding implantation of CRT devices in a broad sample of hospitals in 47 ESC member countries. The large volume of clinical and demographic data collected should reflect current patient selection, implantation, and follow-up practice and provide information relevant for assessing healthcare resource utilization in connection with CRT. The findings of this survey should permit representative benchmarking both nationally and internationally across Europ

    How often should we monitor for reliable detection of atrial fibrillation recurrence? Efficiency considerations and implications for study design

    Get PDF
    OBJECTIVE: Although atrial fibrillation (AF) recurrence is unpredictable in terms of onset and duration, current intermittent rhythm monitoring (IRM) diagnostic modalities are short-termed and discontinuous. The aim of the present study was to investigate the necessary IRM frequency required to reliably detect recurrence of various AF recurrence patterns. METHODS: The rhythm histories of 647 patients (mean AF burden: 12±22% of monitored time; 687 patient-years) with implantable continuous monitoring devices were reconstructed and analyzed. With the use of computationally intensive simulation, we evaluated the necessary IRM frequency to reliably detect AF recurrence of various AF phenotypes using IRM of various durations. RESULTS: The IRM frequency required for reliable AF detection depends on the amount and temporal aggregation of the AF recurrence (p<0.0001) as well as the duration of the IRM (p<0.001). Reliable detection (>95% sensitivity) of AF recurrence required higher IRM frequencies (>12 24-hour; >6 7-day; >4 14-day; >3 30-day IRM per year; p<0.0001) than currently recommended. Lower IRM frequencies will under-detect AF recurrence and introduce significant bias in the evaluation of therapeutic interventions. More frequent but of shorter duration, IRMs (24-hour) are significantly more time effective (sensitivity per monitored time) than a fewer number of longer IRM durations (p<0.0001). CONCLUSIONS: Reliable AF recurrence detection requires higher IRM frequencies than currently recommended. Current IRM frequency recommendations will fail to diagnose a significant proportion of patients. Shorter duration but more frequent IRM strategies are significantly more efficient than longer IRM durations. CLINICAL TRIAL REGISTRATION URL: Unique identifier: NCT00806689

    Mobile health in adults with congenital heart disease: Current use and future needs

    Get PDF
    Objective Many adults with congenital heart disease (CHD) are affected lifelong by cardiac events, particularly arrhythmias and heart failure. Despite the care provided, the cardiac event rate remains high. Mobile health (mHealth) brings opportunities to enhance daily monitoring and hence timely response in an attempt to improve outcome. However, it is not known if adults with CHD are currently using mHealth and what type of mHealth they may need in the near future. Methods Consecutive adult patients with CHD who visited the outpatient clinic at the Academic Medical Center in Amsterdam were asked to fill out questionnaires. Exclusion criteria for this study were mental impairment or inability to read and write Dutch. Results All 118 patients participated (median age 40 (range 18–78) years, 40 % male, 49 % symptomatic) and 92 % owned a smartphone. Whereas only a small minority (14 %) of patients used mHealth, the large majority (75 %) were willing to start. Most patients wanted to use mHealth in order to receive more information on physical health, and advice on progression of symptoms or signs of deterioration. Analyses on age, gender and complexity of defect showed significantly less current smartphone usage at older age, but no difference in interest or preferences in type of mHealth application for the near future. Conclusion The relatively young adult CHD population only rarely uses mHealth, but the majority are motivated to start using mHealth. New mHealth initiatives are required in these patients with a chronic condition who need lifelong surveillance in order to reveal if a reduction in morbidity and mortality and improvement in quality of life can be achieved
    corecore