3,318 research outputs found

    Thermal compensator for closed-cycle helium refrigerator

    Get PDF
    The wave length of an infrared, semiconductor laser diode having an output frequency that is dependent on the diode temperature is maintained substantially constant by maintaining the diode temperature constant. The diode is carried by a cold tip of a closed cycle helium refrigerator. The refrigerator has a tendency to cause the temperature of the cold tip to oscillate. A heater diode and a sensor diode are placed on a thermal heat sink that is the only highly conductive thermal path between the laser diode and the cold tip. The heat sink has a small volume and low thermal capacitance so that the sensing diode is at substantially the same temperature as the heater diode and substantially no thermal lag exists between them. The sensor diode is connected in a negative feedback circuit with the heater diode so that the tendency of the laser diode to thermally oscillate is virtually eliminated

    An active thermal compensator for closed-cycle helium refrigerators

    Get PDF
    A technique was developed for reducing the amplitude of the temperature oscillation in He closed-cyle refrigerators. The device uses a semiconductor diode as a heating element to actively supply a small oscillating input of heat at a point between the laser and the cold-tip to cancel the heat oscillations due to the refrigerator. It was found that the heater diode could drive the temperature of the heat sink more effectively, i.e., with lower current and therefore less heat, if the heat sink was insulated slightly from the rest of the mount. A sine-wave generator was used to drive the programmable supply which provided the offset current to the heater diode. By matching the frequency and phase of the oscillator to that of the refrigerator cycle, and by adjusting the amplitude of the oscillator signal, the temperature fluctuations at the laser could be minimized. Residual fluctuations were about 0.003K peak-to-peak, at an operating temperature of 9.5K

    Snap-in compressible biomedical electrode

    Get PDF
    A replaceable, prefilled electrode enclosed in a plastic seal and suitably adapted for attachment to a reusable, washable cap having snaps thereon is disclosed. The apparatus is particularly adapted for quick positioning of electrodes to obtain an EEG. The individual electrodes are formed of a sponge body which is filled with a conductive electrolyte gel during manufacture. The sponge body is adjacent to a base formed of a conductive plastic material. The base has at its center a male gripper snap. The cap locates the female snap to enable the electrode to be positioned. The electrode can be stored and used quickly by attaching to the female gripper snap. The snap is correctly positioned and located by mounting it in a stretchable cap. The cap is reusable with new electrodes for each use. The electrolyte gel serves as the contact electrode to achieve a good ohmic contact with the scalp

    Review of R and D on Water Hyacinth Utilization in the Philippine Republic

    Get PDF
    The operations of a Filipino inventor were observed with a view toward determining the technical-economic potential of his hyacinth utilization concepts if the highly fibrous portion of the plant were separated from the other components. Subjects of particular interest include: (1) water hyacinth harvesting techniques, volumes and costs; (2) hyacinth defibering processes; and (3) uses of hyacinth materials for production of animal feeds, paper fibers, particle boards, acoustic and insulation boards, various vitamins and minerals (especially Vitamin A), food products, pesticides, and medicinal and pharmaceutical products

    A calibration line list for 807-1167 cm -1 from high resolution Fourier spectroscopy of the 14NH3 nu sub 2 band

    Get PDF
    A calibration list of 295 lines observed over the 800 to 1170 cm to the -1 power region is presented. This list is intended for use as a calibration reference for calibrating diode laser spectra. The transition frequencies were calibrated against the well established laser frequencies of CO2. The estimated uncertainty in the corrected frequencies is + or - 1x.0001 cm to the -1 power

    Technology transfer potential of an automated water monitoring system

    Get PDF
    The nature and characteristics of the potential economic need (markets) for a highly integrated water quality monitoring system were investigated. The technological, institutional and marketing factors that would influence the transfer and adoption of an automated system were studied for application to public and private water supply, public and private wastewater treatment and environmental monitoring of rivers and lakes

    Toward Generalizable Machine Learning Models in Speech, Language, and Hearing Sciences: Power Analysis and Sample Size Estimation

    Full text link
    This study's first purpose is to provide quantitative evidence that would incentivize researchers to instead use the more robust method of nested cross-validation. The second purpose is to present methods and MATLAB codes for doing power analysis for ML-based analysis during the design of a study. Monte Carlo simulations were used to quantify the interactions between the employed cross-validation method, the discriminative power of features, the dimensionality of the feature space, and the dimensionality of the model. Four different cross-validations (single holdout, 10-fold, train-validation-test, and nested 10-fold) were compared based on the statistical power and statistical confidence of the ML models. Distributions of the null and alternative hypotheses were used to determine the minimum required sample size for obtaining a statistically significant outcome ({\alpha}=0.05, 1-\b{eta}=0.8). Statistical confidence of the model was defined as the probability of correct features being selected and hence being included in the final model. Our analysis showed that the model generated based on the single holdout method had very low statistical power and statistical confidence and that it significantly overestimated the accuracy. Conversely, the nested 10-fold cross-validation resulted in the highest statistical confidence and the highest statistical power, while providing an unbiased estimate of the accuracy. The required sample size with a single holdout could be 50% higher than what would be needed if nested cross-validation were used. Confidence in the model based on nested cross-validation was as much as four times higher than the confidence in the single holdout-based model. A computational model, MATLAB codes, and lookup tables are provided to assist researchers with estimating the sample size during the design of their future studies.Comment: Under review at JSLH

    Growth and Histological Effects to Protothaca staminea (Littleneck Clam) of Long-Term Exposure to Chlorinated Sea Water

    Get PDF
    There has been considerable concern about the potential for long-term effects to marine organisms from chlorinated sea water. As part of a larger study to investigate the effects of materials resulting from seawater chlorination on marine organisms, groups of littleneck clams, Protothaca staminea, were exposed to sea water that had been chlorinated. Two experiments were conducted. In one test, groups of littleneck clams were exposed to dilutions of chlorinated sea water that had average chlorine produced oxidant (CPO) concentrations of 16 {micro}g/l or less. In the second test, groups of clams were exposed to chlorinated seawater-unchlorinated seawater mixtures that had target CPO concentrations of 0, 6, 12, 25, 50 and 100 {micro}g/l. In the first experiment, length measurements were made on all clams at approximately one-month intervals for three months. In the second test, length, weight, depth, width and edge etching were used to measure growth, and subsamples were harvested and measured at one-month intervals. In addition, clams were preserved for histological examination. The clams in the first experiment all had negative growth. In the second test, growth was inhibited under all conditions through the first four months of exposure. During the last four months, there was positive signs of growth at the 0, 6 and 12 {micro}g/l CPO test conditions. Histological examination indicates that P. staminea does not adapt well to being held in aquaria. Most clams, tram all test and control conditions, showed evidence of necrosis at one month. This condition seemed to improve with longer exposure at lower CPO concentrations but persisted at CPO concentrations of 25 {micro}g/l and higher. Other histological effects were apparent at the higher exposure concentrations as the length of exposure increased

    Triangular body-cover model of the vocal folds with coordinated activation of the five intrinsic laryngeal muscles

    Get PDF
    Poor laryngeal muscle coordination that results in abnormal glottal posturing is believed to be a primary etiologic factor in common voice disorders such as non-phonotraumatic vocal hyperfunction. Abnormal activity of antagonistic laryngeal muscles is hypothesized to play a key role in the alteration of normal vocal fold biomechanics that results in the dysphonia associated with such disorders. Current low-order models of the vocal folds are unsatisfactory to test this hypothesis since they do not capture the co-contraction of antagonist laryngeal muscle pairs. To address this limitation, a self-sustained triangular body-cover model with full intrinsic muscle control is introduced. The proposed scheme shows good agreement with prior studies using finite element models, excised larynges, and clinical studies in sustained and time-varying vocal gestures. Simulations of vocal fold posturing obtained with distinct antagonistic muscle activation yield clear differences in kinematic, aerodynamic, and acoustic measures. The proposed tool is deemed sufficiently accurate and flexible for future comprehensive investigations of non-phonotraumatic vocal hyperfunction and other laryngeal motor control disorders.Fil: Alzamendi, Gabriel Alejandro. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; ArgentinaFil: Peterson, Sean D.. University of Waterloo; CanadáFil: Erath, Byron D.. Clarkson University; Estados UnidosFil: Hillman, Robert E.. Massachusetts General Hospital; Estados UnidosFil: Zañartu, Matías. Universidad Tecnica Federico Santa Maria.; Chil
    • …
    corecore