116 research outputs found

    Success and Failure of Adult Probationers in Wisconsin

    Get PDF

    Evaluating a new generation of wearable high-density diffuse optical tomography (HD-DOT) technology via retinotopic mapping in the adult brain

    Get PDF
    We investigated the performance of a novel HD-DOT system by replicating a series of classic visual stimulation paradigms. Haemodynamic response functions and cortical activation maps replicated the results obtained with larger fibre-based systems

    ANIMATE: Wearable, flexible, and ultra-lightweight high-density diffuse optical tomography technologies for functional neuroimaging of newborns

    Get PDF
    We have developed a series of wearable high-density diffuse optical tomography (HD-DOT) technologies specifically for neonatal applications. These systems provide an ultra-lightweight form factor, a low profile and high mechanical flexibility. This new technology is validated using a novel, anatomically accurate dynamic phantom

    Evaluating a new generation of wearable high-density diffuse optical tomography technology via retinotopic mapping of the adult visual cortex

    Get PDF
    High-density diffuse optical tomography (HD-DOT) has been shown to approach the resolution and localization accuracy of blood oxygen level dependent-functional magnetic resonance imaging in the adult brain by exploiting densely spaced, overlapping samples of the probed tissue volume, but the technique has to date required large and cumbersome optical fiber arrays. : To evaluate a wearable HD-DOT system that provides a comparable sampling density to large, fiber-based HD-DOT systems, but with vastly improved ergonomics. : We investigated the performance of this system by replicating a series of classic visual stimulation paradigms, carried out in one highly sampled participant during 15 sessions to assess imaging performance and repeatability. : Hemodynamic response functions and cortical activation maps replicate the results obtained with larger fiber-based systems. Our results demonstrate focal activations in both oxyhemoglobin and deoxyhemoglobin with a high degree of repeatability observed across all sessions. A comparison with a simulated low-density array explicitly demonstrates the improvements in spatial localization, resolution, repeatability, and image contrast that can be obtained with this high-density technology. : The system offers the possibility for minimally constrained, spatially resolved functional imaging of the human brain in almost any environment and holds particular promise in enabling neuroscience applications outside of the laboratory setting. It also opens up new opportunities to investigate populations unsuited to traditional imaging technologies. [Abstract copyright: © 2021 The Authors.

    Design and validation of a mechanically flexible and ultra-lightweight high-density diffuse optical tomography system for functional neuroimaging of newborns

    Get PDF
    Neonates are a highly vulnerable population. The risk of brain injury is greater during the first days and weeks after birth than at any other time of life. Functional neuroimaging that can be performed longitudinally and at the cot-side has the potential to improve our understanding of the evolution of multiple forms of neurological injury over the perinatal period. However, existing technologies make it very difficult to perform repeated and/or long-duration functional neuroimaging experiments at the cot-side. We aimed to create a modular, high-density diffuse optical tomography (HD-DOT) technology specifically for neonatal applications that is ultra-lightweight, low profile and provides high mechanical flexibility. We then sought to validate this technology using an anatomically accurate dynamic phantom. An advanced 10-layer rigid-flexible printed circuit board technology was adopted as the basis for the DOT modules, which allows for a compact module design that also provides the flexibility needed to conform to the curved infant scalp. Two module layouts were implemented: dual-hexagon and triple-hexagon. Using in-built board-to-board connectors, the system can be configured to provide a vast range of possible layouts. Using epoxy resin, thermochromic dyes, and MRI-derived 3D-printed moulds, we constructed an electrically switchable, anatomically accurate dynamic phantom. This phantom was used to quantify the imaging performance of our flexible, modular HD-DOT system. Using one particular module configuration designed to cover the infant sensorimotor system, the device provided 36 source and 48 detector positions, and over 700 viable DOT channels per wavelength, ranging from 10 to over an area of approximately . The total weight of this system is only 70 g. The signal changes from the dynamic phantom, while slow, closely simulated real hemodynamic response functions. Using difference images obtained from the phantom, the measured 3D localization error provided by the system at the depth of the cortex was in the of range 3 to 6 mm, and the lateral image resolution at the depth of the neonatal cortex is estimated to be as good as 10 to 12 mm. The HD-DOT system described is ultra-low weight, low profile, can conform to the infant scalp, and provides excellent imaging performance. It is expected that this device will make functional neuroimaging of the neonatal brain at the cot-side significantly more practical and effective. [Abstract copyright: © 2021 The Authors.

    A molten salt test loop for component and instrumentation testing

    Get PDF
    Molten salt is an effective coolant for a wide range of applications, including nuclear reactors, concentrated solar power, and other high temperature industrial heat transfer processes. The technical readiness level of components and instrumentation for high-temperature molten salt applications needs improvement for molten salt to be more widely adopted. A molten salt test loop was designed, built, and commissioned as a test bed to address these issues. The molten salt test loop at Abilene Christian University was built out of 316 stainless steel with a forced flow centrifugal-type pump, and was instrumented for remote operation. A low-temperature molten nitrate salt was used in this system, which was designed to operate at temperatures up to 300 ◦C and flow rates up to 90 liters per minute. This paper describes the loop design, computational fluid dynamics modeling, construction, and commissioning details. An outline of the data acquisition and control systems is presented. Salt samples were taken before and after introduction into the loop, and melting points were measured both before and after salt circulation. Performance of the system is discussed as well as improvements required for higher temperature loops envisioned for the future

    Incorporating connectivity into conservation planning for the optimal representation of multiple species and ecosystem services

    Get PDF
    Funding was provided by the Rainforest Trust foundation. Support was also provided by the Sabah Forest Department, Forest Research Centre, the South East Asia Rainforest Research Partnership, the U.N. Development Programme, the Universiti Malaysia Sabah (FRGS0414-STWN-1/2015), PACOS Trust, BC Initiative, the Natural Environment Research Council UK (grant NE/R009597/1), and the Universities of Aberdeen, Montana, and York. We are grateful to the numerous researchers that collected the data used in our analyses, as well as the local communities and government staff who manage forested areas across Sabah.Peer reviewedPostprin

    A phase II study of weekly cisplatin, 6S-stereoisomer leucovorin and fluorouracil as first-line chemotherapy for elderly patients with advanced gastric cancer

    Get PDF
    The incidence of gastric cancer (GC) increases significantly after the fifth decade and palliative chemotherapy is the ultimate treatment in the majority of patients. We investigated safety and efficacy of a weekly regimen with cisplatin, fluorouracil and leucovorin as first-line chemotherapy for elderly patients with advanced GC. Chemotherapy-naive patients older than 65 years were considered eligible for study entry. Frail elderly patients were identified and excluded according to the following criteria: age >85 years, dependence in one or more activities of daily living (activities of daily living and instrumental activities of daily living scales), three or more comorbid conditions, one or more geriatric syndromes. Chemotherapy consisted of 1-day per week administration of intravenous cisplatin 35 mg m(-2), 6S-stereoisomer leucovorin 250 mg m(-2) and fluorouracil 500 mg m(-2) (PLF). Patients were re-evaluated after eight weekly cycles and six additional weekly administrations were planned for patients without disease progression. A 5-day subcutaneous filgrastim (5 mug Kg(-1) day(-1), days +1-+5) was used after the first treatment delay for neutropenia and maintained thereafter. In the whole group, the best intention-to-treat overall response rate was 43\% (95\% CI: 30-56\%). The time to disease progression and the median survival time were 5.3 and 8.6 months, respectively. Fatigue was the commonest nonhaematologic toxicity (71\% of the patients). Filgrastim was used in 30 patients who showed grade II (20 patients) or grade III (10 patients) neutropenia. Neither grade IV toxicity nor toxic deaths were observed. The weekly PLF regimen resulted safe and effective in elderly patients with advanced GC. This outpatient regimen is based on old and low-cost drugs and it may represent an alternative to new and more expensive combinations
    corecore