211 research outputs found
A new wireless sensor interface using dual-mode radio
The integration of sensors is one of the major tasks in embedded, control and
internet of things (IoT) applications. For the integration mainly digital
interfaces are used, starting from rather simple pulse-width modulation (PWM)
interface to more complex interfaces like CAN (Controller Area Network). Even
though these interfaces are tethered by definition, a wireless realization is
highly welcome in many applications to reduce cable and connector cost,
increase the flexibility and realize new emerging applications like wireless
control systems. Currently used wireless solutions like Bluetooth,
WirelessHART or IO-Link Wireless use dedicated communication standards and
corresponding higher protocol layers to realize the wireless communication.
Due to the complexity of the communication and the protocol handling,
additional latency and jitter are introduced to the data communication that
can meet the requirements for many applications. Even though tunnelling of
other bus data like CAN data is generally also possible the latency and
jitter prevent the tunnelling from being transparent for the bus system. Therefore a new basic technology based on dual-mode
radio is used to realize a wireless communication on the physical layer only,
enabling a reliable and real-time data transfer. As this system operates on
the physical layer it is independent of any higher layers of the OSI (open systems interconnection) model.
Hence it can be used for several different communication systems to replace
the tethered physical layer. A prototype is developed and tested for
real-time wireless PWM, SENT (single-edge nibble transmission) and CAN data
transfer with very low latency and jitter.</p
Spectral analysis of the Forel-Ule ocean colour comparator scale
François Alphonse Forel (1890) and Willi Ule (1892) composed a colour comparator scale, with tints varying from indigo-blue to coca-cola brown, to quantify the colour of natural waters, like seas, lakes and rivers. For each measurement, the observer compares the colour of the water above a submersed white disc (Secchi disc) with the hand-held scale of pre-defined colours. The scale can be well reproduced from a simple recipe for twenty-one coloured chemical solutions and because the ease of its use, the Forel-Ule (FU) scale has been applied globally and intensively by oceanographers and limnologists from the year 1890. Indeed, the archived FU data belong to the oldest oceanographic data sets and do contain information on the changes in geobiophysical properties of natural waters during the last century. In this article we describe the optical properties of the FU-scale and its ability to cover the colours of natural waters, as observed by the human eye. The recipe of the scale and its reproduction is described. The spectral transmission of the tubes, with belonging chromaticity coordinates, is presented. The FU scale, in all its simplicity, is found to be an adequate ocean colour comparator scale. The scale is well characterized, is stable and observations are reproducible. This supports the idea that the large historic data base of FU measurements is coherent and well calibrated. Moreover, the scale can be coupled to contemporary multi-spectral observations with hand-held and satellite-based spectrometers
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear
recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium
detectors equipped with thermal sensors and an electrode design (ID) which
allows to efficiently reject several sources of background. The data indicate
no evidence for an exponential distribution of low-energy nuclear recoils that
could be attributed to WIMP elastic scattering after an exposure of 113 kg.d.
For WIMPs of mass 10 GeV, the observation of one event in the WIMP search
region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent
WIMP-nucleon scattering cross-section, which constrains the parameter space
associated with the findings reported by the CoGeNT, DAMA and CRESST
experiments.Comment: PRD rapid communication accepte
Muon-induced background in the EDELWEISS dark matter search
A dedicated analysis of the muon-induced background in the EDELWEISS dark
matter search has been performed on a data set acquired in 2009 and 2010. The
total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was
measured to be \,muons/m/d. The
modular design of the muon-veto system allows the reconstruction of the muon
trajectory and hence the determination of the angular dependent muon flux in
LSM. The results are in good agreement with both MC simulations and earlier
measurements. Synchronization of the muon-veto system with the phonon and
ionization signals of the Ge detector array allowed identification of
muon-induced events. Rates for all muon-induced events and of WIMP-like events were extracted. After
vetoing, the remaining rate of accepted muon-induced neutrons in the
EDELWEISS-II dark matter search was determined to be at 90%\,C.L. Based on
these results, the muon-induced background expectation for an anticipated
exposure of 3000\,\kgd\ for EDELWEISS-3 is
events.Comment: 21 pages, 16 figures, Accepted for publication in Astropart. Phy
Background studies for the EDELWEISS dark matter experiment
The EDELWEISS-II collaboration has completed a direct search for WIMP dark
matter using cryogenic Ge detectors (400 g each) and 384 kgdays of
effective exposure. A cross-section of pb is excluded at
90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to
probe spin-independent WIMP-nucleon cross-sections down to a few
pb. We present here the study of gamma and neutron background
coming from radioactive decays in the set-up and shielding materials. We have
carried out Monte Carlo simulations for the completed EDELWEISS-II setup with
GEANT4 and normalised the expected background rates to the measured
radioactivity levels (or their upper limits) of all materials and components.
The expected gamma-ray event rate in EDELWEISS-II at 20-200 keV agrees with the
observed rate of 82 events/kg/day within the uncertainties in the measured
concentrations. The calculated neutron rate from radioactivity of 1.0-3.1
events (90% C.L.) at 20-200 keV in the EDELWEISS-II data together with the
expected upper limit on the misidentified gamma-ray events (), surface
betas (), and muon-induced neutrons (), do not contradict 5
observed events in nuclear recoil band. We have then extended the simulation
framework to the EDELWEISS-III configuration with 800 g crystals, better
material purity and additional neutron shielding inside the cryostat. The
gamma-ray and neutron backgrounds in 24 kg fiducial mass of EDELWEISS-III have
been calculated as 14-44 events/kg/day and 0.7-1.4 events per year,
respectively. The results of the background studies performed in the present
work have helped to select better purity components and improve shielding in
EDELWEISS-III to further reduce the expected rate of background events in the
next phase of the experiment.Comment: 15 pages, 9 figures, to be published in Astroparticle Physic
Axion searches with the EDELWEISS-II experiment
We present new constraints on the couplings of axions and more generic
axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS
experiment, located at the Underground Laboratory of Modane, primarily aims at
the direct detection of WIMPs using germanium bolometers. It is also sensitive
to the low-energy electron recoils that would be induced by solar or dark
matter axions. Using a total exposure of up to 448 kg.d, we searched for
axion-induced electron recoils down to 2.5 keV within four scenarios involving
different hypotheses on the origin and couplings of axions. We set a 95% CL
limit on the coupling to photons GeV in
a mass range not fully covered by axion helioscopes. We also constrain the
coupling to electrons, , similar to the more
indirect solar neutrino bound. Finally we place a limit on , where is the
effective axion-nucleon coupling for Fe. Combining these results we
fully exclude the mass range keV for DFSZ axions and
keV for KSVZ axions
Increased searching and handling effort in tall swards lead to a Type IV functional response in small grazing herbivores
Understanding the functional response of species is important in comprehending the species’ population dynamics and the functioning of multi-species assemblages. A Type II functional response, where instantaneous intake rate increases asymptotically with sward biomass, is thought to be common in grazers. However, at tall, dense swards, food intake might decline due to mechanical limitations or if animals selectively forage on the most nutritious parts of a sward, leading to a Type IV functional response, especially for smaller herbivores. We tested the predictions that bite mass, cropping time, swallowing time and searching time increase, and bite rate decreases with increasing grass biomass for different-sized Canada geese (Branta canadensis) foraging on grass swards. Bite mass indeed showed an increasing asymptotic relationship with grass biomass. At high biomass, difficulties in handling long leaves and in locating bites were responsible for increasing cropping, swallowing, and searching times. Constant bite mass and decreasing bite rate caused the intake rate to decrease at high sward biomass after reaching an optimum, leading to a Type IV functional response. Grazer body mass affected maximum bite mass and intake rate, but did not change the shape of the functional response. As grass nutrient contents are usually highest in short swards, this Type IV functional response in geese leads to an intake rate that is maximised in these swards. The lower grass biomass at which intake rate was maximised allows resource partitioning between different-sized grazers. We argue that this Type IV functional response is of more importance than previously thought
- …