5 research outputs found

    Optimizing hepcidin measurement with a proficiency test framework and standardization improvement

    No full text
    Hepcidin measurement advances insights in pathophysiology, diagnosis, and treatment of iron disorders, but requires analytically sound and standardized measurement procedures (MPs). Recent development of a two-level secondary reference material (sRM) for hepcidin assays allows worldwide standardization. However, no proficiency testing (PT) schemes to ensure external quality assurance (EQA) exist and the absence of a high calibrator in the sRM set precludes optimal standardization. We developed a pilot PT together with the Dutch EQA organization Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek (SKML) that included 16 international hepcidin MPs. The design included 12 human serum samples that allowed us to evaluate accuracy, linearity, precision and standardization potential. We manufactured, value-assigned, and validated a high-level calibrator in a similar manner to the existing low- and middle-level sRM. The pilot PT confirmed logistical feasibility of an annual scheme. Most MPs demonstrated linearity (R2>0.99) and precision (duplicate CV>12.2%), although the need for EQA was shown by large variability in accuracy. The high-level calibrator proved effective, reducing the inter-assay CV from 42.0% (unstandardized) to 14.0%, compared to 17.6% with the two-leveled set. The calibrator passed international homogeneity criteria and was assigned a value of 9.07 ± 0.24 nmol/L. We established a framework for future PT to enable laboratory accreditation, which is essential to ensure quality of hepcidin measurement and its use in patient care. Additionally, we showed optimized standardization is possible by extending the current sRM with a third high calibrator, although international implementation of the sRM is a prerequisite for its success

    The MK5/PRAK Kinase and Myc Form a Negative Feedback Loop that Is Disrupted during Colorectal Tumorigenesis

    No full text
    Expression of the Myc oncoprotein is downregulated in response to stress signals to allow cells to cease proliferation and escape apoptosis, but the mechanisms involved in this process are poorly understood. Cell cycle arrest in response to DNA damage requires downregulation of Myc via a p53-independent signaling pathway. Here we have used siRNA screening of the human kinome to identify MAPKAPK5 (MK5, PRAK) as a negative regulator of Myc expression. MK5 regulates translation of Myc, since it is required for expression of miR-34b and miR-34c that bind to the 3′UTR of MYC. MK5 activates miR-34b/c expression via phosphorylation of FoxO3a, thereby promoting nuclear localization of FoxO3a and enabling it to induce miR-34b/c expression and arrest proliferation. Expression of MK5 in turn is directly activated by Myc, forming a negative feedback loop. MK5 is downregulated in colon carcinomas, arguing that this feedback loop is disrupted during colorectal tumorigenesis

    Provisional standardization of hepcidin assays:Creating a traceability chain with a primary reference material, candidate reference method and a commutable secondary reference material

    No full text
    Background Hepcidin concentrations measured by various methods differ considerably, complicating interpretation. Here, a previously identified plasma-based candidate secondary reference material (csRM) was modified into a serum-based two-leveled sRM. We validated its functionality to increase the equivalence between methods for international standardization. Methods We applied technical procedures developed by the International Consortium for Harmonization of Clinical Laboratory Results. The sRM, consisting of lyophilized serum with cryolyoprotectant, appeared commutable among nine different measurement procedures using 16 native human serum samples in a first round robin (RR1). Harmonization potential of the sRM was simulated in RR1 and evaluated in practice in RR2 among 11 measurement procedures using three native human plasma samples. Comprehensive purity analysis of a candidate primary RM (cpRM) was performed by state of the art procedures. The sRM was value assigned with an isotope dilution mass spectrometry-based candidate reference method calibrated using the certified pRM. Results The inter-assay CV without harmonization was 42.1% and 52.8% in RR1 and RR2, respectively. In RR1, simulation of harmonization with sRM resulted in an inter-assay CV of 11.0%, whereas in RR2 calibration with the material resulted in an inter-assay CV of 19.1%. Both the sRM and pRM passed international homogeneity criteria and showed long-term stability. We assigned values to the low (0.95\ub10.11 nmol/L) and middle concentration (3.75\ub10.17 nmol/L) calibrators of the sRM. Conclusions Standardization of hepcidin is possible with our sRM, which value is assigned by a pRM. We propose the implementation of this material as an international calibrator for hepcidin

    Analytical comparison of ELISA and mass spectrometry for quantification of serum hepcidin in critically ill patients

    No full text
    International audienceAim: To compare methods of quantifying serum hepcidin (based on MS and ELISA) and their ability to diagnose true iron deficiency anemia in critically ill patients. Materials & methods: Serum hepcidin was measured in 119 critically ill patients included in the HEPCIDANE clinical trial, using either an ultra-sensitive ELISA kit (from DRG) or two different MS methods. Results: The results show a good correlation between the different methods studied. The Bland–Altman analysis and the Kappa test for clinical groups show a good or very good agreement between the different tests. Conclusion: ELISA or MS show a satisfactory commutability to quantify serum hepcidin. This is of great importance for the determination of therapeutic strategies in iron deficiency
    corecore