395 research outputs found

    Superconducting and structural properties of plasma sprayed YBaCuO layers deposited on metallic substrates

    Get PDF
    The properties of plasma sprayed Y-Ba-Cu-O coatings deposited on metallic substrates are studied. Stainless steel, nickel steels and pure nickel are used as substrate. Y-Ba-Cu-O deposited on stainless steel and nickel steel reacts with the substrate. This interaction can be suppressed by using an yttria-stabilized zirconia (YsZ) diffusion barrier. However, after heat treatment the Y-Ba-Cu-O layers on YsZ show cracks perpendicular to the surface. As a result the critical current density is very low. The best results are obtained for Y-Ba-Cu-O deposited on pure nickel; here no cracks perpendicular to the surface are observed. The critical current increases with the anneal temperature but annealing for longer than 10 h does not seem to improve the superconducting properties any further

    Transport current dependence of the hysterisis loss in silver sheathed BSCCO-2212 conductors

    Get PDF
    A technique is described to study the critical current density and penetration fieldassociated with the transport current in a silver sheathed BSCCO conductor. A transport current flowing in a conductor in a varying magnetic field will only influence magnetisation currents that are in competition with the transport current, i.e. currents that use the same path. By measuring the transport current dependence of the magnetisation loss information can be obtained on the related critical current and penetration field. The combination of these two quantities contains information about the geometry of the current distribution and can be used to test different models for the current distribution in BSCCO conductors

    First principles modelling of magnesium titanium hydrides

    Get PDF
    Mixing Mg with Ti leads to a hydride Mg(x)Ti(1-x)H2 with markedly improved (de)hydrogenation properties for x < 0.8, as compared to MgH2. Optically, thin films of Mg(x)Ti(1-x)H2 have a black appearance, which is remarkable for a hydride material. In this paper we study the structure and stability of Mg(x)Ti(1-x)H2, x= 0-1 by first-principles calculations at the level of density functional theory. We give evidence for a fluorite to rutile phase transition at a critical composition x(c)= 0.8-0.9, which correlates with the experimentally observed sharp decrease in (de)hydrogenation rates at this composition. The densities of states of Mg(x)Ti(1-x)H2 have a peak at the Fermi level, composed of Ti d states. Disorder in the positions of the Ti atoms easily destroys the metallic plasma, however, which suppresses the optical reflection. Interband transitions result in a featureless optical absorption over a large energy range, causing the black appearance of Mg(x)Ti(1-x)H2.Comment: 22 pages, 9 figures, 4 table

    Protocol for a systematic review and individual patient data meta-analysis of benefit of so-called lung-protective ventilation settings in patients under general anesthesia for surgery

    Get PDF
    BACKGROUND: Almost all patients under general anesthesia for surgery need mechanical ventilation. The harmful effects of short-term intra-operative ventilation on pulmonary integrity are increasingly recognized. Recent investigations suggest protection against so-called ventilation-associated lung injury with the use of lower tidal volumes and/or the use of higher levels of positive end-expiratory pressure (PEEP). This review and meta-analysis will evaluate the effects of these protective measures on pulmonary and extra-pulmonary complications, and try to discriminate the effects of lower tidal volumes from those of higher levels of PEEP. METHODS/DESIGN: The Medline database will be searched for observational studies and randomized controlled trials of intra-operative ventilation. Individual patient data will be collected from databases obtained via direct contact with corresponding authors of original articles. The primary endpoint is development of postoperative acute respiratory distress syndrome, the most important postoperative pulmonary complication. Secondary endpoints include hospital length of stay and hospital mortality, and reported intra-operative and postoperative pulmonary and extra-pulmonary complications. Emphasis is put on separating the effects of lower tidal volumes from those of higher levels of PEEP. DISCUSSION: This will be the first meta-analysis of intra-operative ventilation using individual patient data from observational studies and randomized controlled trials. The large sample size could allow discrimination of the effect of the two most frequently used protective measures - that is, lower tidal volumes and higher levels of PEEP. The results of this review and meta-analysis can be used in designing future trials of ventilation

    Using differential reinforcement of high rates of behavior to improve work productivity : a replication and extension

    Full text link
    Background: Due to deficits in adaptive and cognitive functioning, productivity may pose challenges for individuals with intellectual disability in the workplace.Method: Using a changing‐criterion embedded in a multiple baseline across partici‐pants design, we examined the effects of differential reinforcement of high rates of behaviour (DRH) on the rate of data entry (i.e., productivity) in four adults with intel‐lectual disability.Results: Although the DRH procedure increased the rate of correct data entry in all four participants, none of the participants achieved the criterion that we set with novice undergraduate students.Conclusions: Our results indicate that DRH is an effective intervention to increase rate of correct responding in individuals with intellectual disability, but that achiev‐ing the same productivity as workers without disability may not always be possible

    Domains in CoCr investigated by neutron depolarization

    Full text link

    Noise properties of direct current SQUIDs with quasiplanar YBa2Cu3O7 Josephson junctions

    Get PDF
    We describe the noise performance of dc SQUIDs fabricated with quasiplanar ramp‐type Josephson junctions on the basis of c‐axis‐oriented YBa2Cu3O7/PrBa2Cu3O7 thin‐film heterostructures. The noise spectrum of the dc SQUIDs was measured with dc‐ and ac‐bias schemes at different temperatures and showed values below 10−5 Ω0/Hz1/2 down to frequencies of about 1 Hz at 70 K. Up to now for the magnetic fluxnoise and the energy resolution obtained at 1 kHz and 77 K the best values were 2.5×10−6, Ω0/Hz1/2 and 3×10−31 J/Hz, respectively. A study of the white and 1/fnoises of the SQUIDs was performed. The influence of magnetic flux, bias current, high static magnetic fields, and aging on the SQUID noise were investigated. The junctions and devices do not degrade due to aging in air or thermal cycling

    Rationale and study design of PROVHILO - a worldwide multicenter randomized controlled trial on protective ventilation during general anesthesia for open abdominal surgery

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Post-operative pulmonary complications add to the morbidity and mortality of surgical patients, in particular after general anesthesia >2 hours for abdominal surgery. Whether a protective mechanical ventilation strategy with higher levels of positive end-expiratory pressure (PEEP) and repeated recruitment maneuvers; the "open lung strategy", protects against post-operative pulmonary complications is uncertain. The present study aims at comparing a protective mechanical ventilation strategy with a conventional mechanical ventilation strategy during general anesthesia for abdominal non-laparoscopic surgery.</p> <p>Methods</p> <p>The PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure ("PROVHILO") trial is a worldwide investigator-initiated multicenter randomized controlled two-arm study. Nine hundred patients scheduled for non-laparoscopic abdominal surgery at high or intermediate risk for post-operative pulmonary complications are randomized to mechanical ventilation with the level of PEEP at 12 cmH<sub>2</sub>O with recruitment maneuvers (the lung-protective strategy) or mechanical ventilation with the level of PEEP at maximum 2 cmH<sub>2</sub>O without recruitment maneuvers (the conventional strategy). The primary endpoint is any post-operative pulmonary complication.</p> <p>Discussion</p> <p>The PROVHILO trial is the first randomized controlled trial powered to investigate whether an open lung mechanical ventilation strategy in short-term mechanical ventilation prevents against postoperative pulmonary complications.</p> <p>Trial registration</p> <p>ISRCTN: <a href="http://www.controlled-trials.com/ISRCTN70332574">ISRCTN70332574</a></p

    Driving pressure during general anesthesia for open abdominal surgery (DESIGNATION) : study protocol of a randomized clinical trial

    Get PDF
    Background Intraoperative driving pressure (Delta P) is associated with development of postoperative pulmonary complications (PPC). When tidal volume (V-T) is kept constant, Delta P may change according to positive end-expiratory pressure (PEEP)-induced changes in lung aeration. Delta P may decrease if PEEP leads to a recruitment of collapsed lung tissue but will increase if PEEP mainly causes pulmonary overdistension. This study tests the hypothesis that individualized high PEEP, when compared to fixed low PEEP, protects against PPC in patients undergoing open abdominal surgery. Methods The "Driving prESsure durIng GeNeral AnesThesIa for Open abdomiNal surgery trial" (DESIGNATION) is an international, multicenter, two-group, double-blind randomized clinical superiority trial. A total of 1468 patients will be randomly assigned to one of the two intraoperative ventilation strategies. Investigators screen patients aged >= 18 years and with a body mass index <= 40 kg/m(2), scheduled for open abdominal surgery and at risk for PPC. Patients either receive an intraoperative ventilation strategy with individualized high PEEP with recruitment maneuvers (RM) ("individualized high PEEP") or one in which PEEP of 5 cm H2O without RM is used ("low PEEP"). In the "individualized high PEEP" group, PEEP is set at the level at which Delta P is lowest. In both groups of the trial, V-T is kept at 8 mL/kg predicted body weight. The primary endpoint is the occurrence of PPC, recorded as a collapsed composite of adverse pulmonary events. Discussion DESIGNATION will be the first randomized clinical trial that is adequately powered to compare the effects of individualized high PEEP with RM versus fixed low PEEP without RM on the occurrence of PPC after open abdominal surgery. The results of DESIGNATION will support anesthesiologists in their decisions regarding PEEP settings during open abdominal surgery
    • 

    corecore