160 research outputs found
Evaluating Contaminants of Emerging Concern in Commercial Biosolid-based Fertilizers
The production and popularity of commercially available biosolid-based fertilizers are increasing because of their economic, environmental, and plant nutrition benefits, particularly in urban and suburban areas. Because biosolid-based fertilizers are derived from waste water treatment plant residuals, we hypothesized that there is the potential for micropollutants to persist in these products. Their presence would be of particular concern due to their potential impact on human and ecological health and risk of bioaccumulation. This study involves quantifying contaminants of emerging concern in three biosolid-based fertilizers, and 2 non-biosolid-based fertilizers, a composted animal manure and an organic compost. Our extraction method employed ultrasonic assisted solid-liquid extraction followed by a 20 h equilibration during which samples were rotated end-over-end. Prior to analysis, all solvent extracts were concentrated under nitrogen and cleaned up with ENVI-carb to minimize matrix effects during sample analysis. High performance liquid chromatography tandem mass spectrometry (LC-MSMS) and quadrupole time of flight liquid chromatography mass spectrometry (QTOF-LCMS) were used to identify and quantify a suite of micropollutants including perfluoroalkyl substances (PFASs), hormones, parabens, pharmaceuticals, and personal care products. Variable levels of contaminants ranging from 8.22 to 11,300 ppb were found in the biosolid fertilizers, while the nonbiosolid fertilizers contained much smaller concentrations. Milorganite had 14 contaminants, OceanGRO had 13, Elite Lawn had 16, New Plant Life Composted Manure had 1, and Pro-Mix Ultimate Organic Mix had 3. Although many of these chemicals persist in commercially available biosolid-based fertilizers, future research is still needed to determine what, if any, potential risk these contaminants may pose to human or ecological health at the concentrations detected
Noise Thermometry with Two Weakly Coupled Bose-Einstein Condensates
Here we report on the experimental investigation of thermally induced
fluctuations of the relative phase between two Bose-Einstein condensates which
are coupled via tunneling. The experimental control over the coupling strength
and the temperature of the thermal background allows for the quantitative
analysis of the phase fluctuations. Furthermore, we demonstrate the application
of these measurements for thermometry in a regime where standard methods fail.
With this we confirm that the heat capacity of an ideal Bose gas deviates from
that of a classical gas as predicted by the third law of thermodynamics.Comment: 4 pages, 4 figure
Realization of a single Josephson junction for Bose-Einstein condensates
We report on the realization of a double-well potential for Rubidium-87
Bose-Einstein condensates. The experimental setup allows the investigation of
two different dynamical phenomena known for this system - Josephson
oscillations and self-trapping. We give a detailed discussion of the
experimental setup and the methods used for calibrating the relevant
parameters. We compare our experimental findings with the predictions of an
extended two-mode model and find quantitative agreement
ПЕРСПЕКТИВИ СТВОРЕННЯ ЕФЕКТИВНО ФУНКЦІОНУЮЧОГО ФІНАНСОВОГО МЕХАНІЗМУ ІННОВАЦІЙНОГО РОЗВИТКУ ПІДПРИЄМСТВ В УКРАЇНІ
Висвітлюються проблеми і перспективи
створення ефективно функціонуючого
фінансового механізму інноваційного розвитку
підприємств в Україні. Розроблено модель, яка
забезпечує формування стратегії інноваційного
розвитку підприємства.Problems and prospects of effectively
functioning financial mechanism's creation of
innovative enterprise development in Ukraine are
lighted. A model is developed, which provides
forming of the innovative strategy enterprises'
development
A Single Laser System for Ground-State Cooling of 25-Mg+
We present a single solid-state laser system to cool, coherently manipulate
and detect Mg ions. Coherent manipulation is accomplished by
coupling two hyperfine ground state levels using a pair of far-detuned Raman
laser beams. Resonant light for Doppler cooling and detection is derived from
the same laser source by means of an electro-optic modulator, generating a
sideband which is resonant with the atomic transition. We demonstrate
ground-state cooling of one of the vibrational modes of the ion in the trap
using resolved-sideband cooling. The cooling performance is studied and
discussed by observing the temporal evolution of Raman-stimulated sideband
transitions. The setup is a major simplification over existing state-of-the-art
systems, typically involving up to three separate laser sources
Recommended from our members
Can information affect sensory perceptions? Evidence from a survey on Italian organic food consumers
This paper aims to investigate the influence of information on consumers’ preferences and sensory perceptions of organic food using a sample of 301 Italian organic food consumers. Consumers stated their preferences for “core organic” attributes, labels and information on food products and performed blind and informed tests on strawberry yoghurts and cookies. Data were analysed using descriptive analysis, Mann-Whitney U tests and Wilcoxon signed-rank test. Results revealed that consumers appreciate “core organic” attributes, like artisanal production and variability of sensory attributes. Comparing blind and informed tests, results showed that information affects the overall liking of products and consumers’ perception of product-specific sensory attributes. However, the influence of information on sensory perceptions depends on the product category, sensory attributes and the type of information provided
Molecules cooled below the Doppler limit
The ability to cool atoms below the Doppler limit -- the minimum temperature reachable by Doppler cooling -- has been essential to most experiments with quantum degenerate gases, optical lattices and atomic fountains, among many other applications. A broad set of new applications await ultracold molecules, and the extension of laser cooling to molecules has begun. A molecular magneto-optical trap has been demonstrated, where molecules approached the Doppler limit. However, the sub-Doppler temperatures required for most applications have not yet been reached. Here we cool molecules to 50 uK, well below the Doppler limit, using a three-dimensional optical molasses. These ultracold molecules could be loaded into optical tweezers to trap arbitrary arrays for quantum simulation, launched into a molecular fountain for testing fundamental physics, and used to study ultracold collisions and ultracold chemistry
Incidence of epidural haematoma and neurological injury in cardiovascular patients with epidural analgesia/anaesthesia: systematic review and meta-analysis
BACKGROUND: Epidural anaesthesia is used extensively for cardiothoracic and vascular surgery in some centres, but not in others, with argument over the safety of the technique in patients who are usually extensively anticoagulated before, during, and after surgery. The principle concern is bleeding in the epidural space, leading to transient or persistent neurological problems. METHODS: We performed an extensive systematic review to find published cohorts of use of epidural catheters during vascular, cardiac, and thoracic surgery, using electronic searching, hand searching, and reference lists of retrieved articles. RESULTS: Twelve studies included 14,105 patients, of whom 5,026 (36%) had vascular surgery, 4,971 (35%) cardiac surgery, and 4,108 (29%) thoracic surgery. There were no cases of epidural haematoma, giving maximum risks following epidural anaesthesia in cardiac, thoracic, and vascular surgery of 1 in 1,700, 1 in 1,400 and 1 in 1,700 respectively. In all these surgery types combined the maximum expected rate would be 1 in 4,700. In all these patients combined there were eight cases of transient neurological injury, a rate of 1 in 1,700 (95% confidence interval 1 in 3,300 to 1 in 850). There were no cases of persistent neurological injury (maximum expected rate 1 in 4,600). CONCLUSION: These estimates for cardiothoracic epidural anaesthesia should be the worst case. Limitations are inadequate denominators for different types of surgery in anticoagulated cardiothoracic or vascular patients more at risk of bleeding
- …