184 research outputs found
Sub-kHz-level relative stabilization of an intracavity doubled continuous wave optical parametric oscillator using Pound-Drever-Hall scheme
We report the relative frequency stabilization of an intracavity frequency
doubled singly resonant optical parametric oscillator on a Fabry-Perot\'etalon.
The red/orange radiation produced by the frequency doubling of the intracavity
resonant idler is stabilized using the Pound-Drever-Hall locking technique. The
relative frequency noise of this orange light, when integrated from 1 Hz to 50
kHz, corresponds to a standard deviation of 700 Hz. The frequency noise of the
pump laser is shown experimentally to be transferred to the non resonant signal
beam
Laser cooling of trapped ytterbium ions with an ultraviolet diode laser
We demonstrate an ultraviolet diode laser system for cooling of trapped
ytterbium ions. The laser power and linewidth are comparable to previous
systems based on resonant frequency doubling, but the system is simpler, more
robust, and less expensive. We use the laser system to cool small numbers of
ytterbium ions confined in a linear Paul trap. From the observed spectra, we
deduce final temperatures < 270 mK.Comment: submitted to Opt. Let
The optical calcium frequency standards of PTB and NIST
We describe the current status of the Ca optical frequency standards with
laser-cooled neutral atoms realized in two different laboratories for the
purpose of developing a possible future optical atomic clock.
Frequency measurements performed at the Physikalisch-Technische Bundesanstalt
(PTB) and the National Institute of Standards and Technology (NIST) make the
frequency of the clock transition of 40Ca one of the best known optical
frequencies (relative uncertainty 1.2e-14) and the measurements of this
frequency in both laboratories agree to well within their respective
uncertainties.
Prospects for improvement by orders of magnitude in the relative uncertainty
of the standard look feasible.Comment: 13 pages, 11 figures, to appear in Comptes Rendus Physiqu
Doppler cooling and trapping on forbidden transitions
Ultracold atoms at temperatures close to the recoil limit have been achieved
by extending Doppler cooling to forbidden transitions. A cloud of ^40Ca atoms
has been cooled and trapped to a temperature as low as 6 \mu K by operating a
magneto-optical trap on the spin-forbidden intercombination transition.
Quenching the long-lived excited state with an additional laser enhanced the
scattering rate by a factor of 15, while a high selectivity in velocity was
preserved. With this method more than 10% of pre-cooled atoms from a standard
magneto-optical trap have been transferred to the ultracold trap. Monte-Carlo
simulations of the cooling process are in good agreement with the experiments
Pre-ejection period by radial artery tonometry supplements echo doppler findings during biventricular pacemaker optimization
<p>Abstract</p> <p>Background</p> <p>Biventricular (Biv) pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP) assessment by radial artery tonometry in guiding Biv pacemaker optimization.</p> <p>Methods</p> <p>Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV) ejection fraction (EF) 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI), ejection time (ET), myocardial performance index (MPI), radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated.</p> <p>Results</p> <p>Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p < 0.001), LV VTI (15.9 ± 4.8 cm to 18.4 ± 5.1 cm, p < 0.001) and MPI (0.57 ± 0.2 to 0.45 ± 0.13, p < 0.001) and in PEP (246.7 ± 36.1 ms to 234.7 ± 35.5 ms, p = 0.003), PEP/ET (0.88 ± 0.21 to 0.79 ± 0.17, p < 0.001), and PEP/VTI (17.3 ± 7 to 13.78 ± 4.7, p < 0.001). The correlation between comprehensive echo Doppler and radial artery tonometry-PEP guided optimal atrioventricular delay (AVD) and optimal interventricular delay (VVD) was 0.75 (p < 0.001) and 0.69 (p < 0.001) respectively. In 29 patients with follow up assessment, New York Heart Association (NYHA) class reduced from 2.5 ± 0.8 to 2.0 ± 0.9 (p = 0.004) at 1.8 ± 1.4 months.</p> <p>Conclusion</p> <p>An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.</p
Can Echocardiographic Findings Predict Falls in Older Persons?
Background. The European and American guidelines state the need for echocardiography in patients with syncope. 50% of older adults with syncope present with a fall. Nonetheless, up to now no data have been published addressing echocardiographic abnormalities in older fallers. Method and Findings. In order to determine the association between echocardiographic abnormalities and falls in older adults, we performed a prospective cohort study, in which 215 new consecutive referrals (age 77.4 SD 6.0) of a geriatric outpatient clinic of a Dutch university hospital were included. During the previous year, 139 had experienced a fall. At baseline, all patients underwent routine two-dimensional and Doppler echocardiography. Falls were recorded during a three-month follow-up. Multivariate adjustment for compounders was performed with a Cox proportional hazards model. 557 patients (26%) fell at least once during follow-up. The adjusted hazard ratio of a fall during follow-up was 135 (95% Cl, 1.08-1.71) for pulmonary hypertension, 1.66 (95% Cl, 1.01 to 2.89) for 4-initial regurgitation, 2.41 (95% Cl, 1.32 to 4.37) for tricuspid regurgitation and 1.76 (95% Cl, 1.03 to 3.01) for pulmonary regurgitation. For aoitic regurgitation the risk of a fall was also increased, but non-significantly. (hazard ratio, 1.57 [95% Cl 0.85 to 2.92]). Trend analysis of the severity of the difterent regurgitations showed a significant relationship for mitral, tricuspid and pulmonary valve regurgitation and pulmonary hypertension. Conclusions. Echo(Dopler)cardiography can be useful in order to identify risk indicators for falling. Presence of pulmonary hypertension or regurgitation of mitral, tricuspid or pulmonary valves was associated with a higher fall risk. Our study indicates that the diagnostic work-up for falls in older adults might be improved by adding an echo(Doppler)cardiogram in selected groups
The NOX toolbox: validating the role of NADPH oxidases in physiology and disease
Reactive oxygen species (ROS) are cellular signals but also disease triggers; their relative excess (oxidative stress) or shortage (reductive stress) compared to reducing equivalents are potentially deleterious. This may explain why antioxidants fail to combat diseases that correlate with oxidative stress. Instead, targeting of disease-relevant enzymatic ROS sources that leaves physiological ROS signaling unaffected may be more beneficial. NADPH oxidases are the only known enzyme family with the sole function to produce ROS. Of the catalytic NADPH oxidase subunits (NOX), NOX4 is the most widely distributed isoform. We provide here a critical review of the currently available experimental tools to assess the role of NOX and especially NOX4, i.e. knock-out mice, siRNAs, antibodies, and pharmacological inhibitors. We then focus on the characterization of the small molecule NADPH oxidase inhibitor, VAS2870, in vitro and in vivo, its specificity, selectivity, and possible mechanism of action. Finally, we discuss the validation of NOX4 as a potential therapeutic target for indications including stroke, heart failure, and fibrosis
- …