106 research outputs found

    Comparison of venous couplers versus hand-sewn technique in 4577 cases of DIEP-flap breast reconstructions – A multicenter study

    Get PDF
    Introduction Venous anastomosis remains to be a challenging step in microsurgical tissue transfer and venous complications constitute to a common reason for free flap failure. While several studies have compared mechanical vs. hand-sewn venous anastomoses, there is no large-series study comparing the type of anastomosis exclusively in DIEP flap breast reconstructions. Patients and Methods Between 2011 and 2019, 3926 female patients underwent 4577 free DIEP-flap breast reconstructions in 22 different breast cancer centers. Patient data was collected via an online database, files were screened and cases were divided into a hand- (HA) and a coupler-anastomosis (CA) group. Complications were accounted for and the two groups were then compared. Results Mean ischemia time was significantly shorter in the CA group (46.88 +/- 26.17 vs. 55.48 +/- 24.70 min; p < .001), whereas mean operative time was comparable (316 +/- 134.01 vs. 320.77 +/- 120.29 minutes; p = .294). We found no significant difference between both groups regarding the rate of partial (CA: 1.0% vs. HA: 1.3%) and total flap loss (CA: 2.2% vs. HA: 1.8%). However, revision rates were significantly higher in the CA group (CA: 10.5% vs. HA: 7.9%; p = .003), with higher numbers of arterial (2.3 vs. 0.9%; p < .001) and venous thromboses (3.4 vs. 1.8%; p = .001) accounting for this finding. Conclusions All taken into account, our findings do support the feasibility of venous coupler anastomoses in principle, however the inflationary use of coupler devices should be evaluated critically

    Do-It-Yourself Preoperative High-Resolution Ultrasound-Guided Flap Design of the Superficial Circumflex Iliac Artery Perforator Flap (SCIP)

    Get PDF
    The superficial circumflex iliac artery perforator (SCIP) flap is a well-documented, thin, free tissue flap with a minimal donor site morbidity, and has the potential to become the new method for resurfacing moderate-size skin defects. The aim of this study is to describe an easy, reliable, systematic, and standardized approach for preoperative SCIP flap design and perforator characterization, using color-coded duplex sonography (CCDS). A list of customized settings and a straightforward algorithm are presented, which are easily applied by an operator with minimal experience. Specific settings for SCIP flap perforator evaluation were investigated and tested on 12 patients. Deep and superficial superficial circumflex iliac artery (SCIA) branches, along with their corresponding perforators and cutaneous veins, were marked individually with a permanent marker and the anatomy was verified intraoperatively. From this, a simplified procedure for preoperative flap design of the SCIP flap was developed. Branches could be localized and evaluated in all patients. A preoperative structured procedure for ultrasonically guided flap design of the SCIP flap is described. A 100% correlation between the number and emergence points of the branches detected by preoperative CCDS mapping and the intraoperative anatomy was found

    Using High-Resolution Ultrasound to Assess Post-Facial Paralysis Synkinesis—Machine Settings and Technical Aspects for Facial Surgeons

    Get PDF
    Background: Synkinesis of the facial musculature is a detrimental sequalae in post-paralytic facial palsy (PPFP) patients. Detailed knowledge on the technical requirements and device properties in a high-resolution ultrasound (HRUS) examination is mandatory for a reliable facial muscle assessment in PPFP patients. We therefore aimed to outline the key steps in a HRUS examination and extract an optimized workflow schema. Methods: From December 2020 to April 2021, 20 patients with unilateral synkinesis underwent HRUS. All HRUS examinations were performed by the first author using US devices with linear multifrequency transducers of 4–18 MHz, including a LOGIQ E9 and a LOGIQ S7 XDclear (GE Healthcare; Milwaukee, WI, USA), as well as Philips Affinity 50G (Philips Health Systems; Eindhoven, the Netherlands). Results: Higher-frequency and multifrequency linear probes ≥15 MHz provided superior imaging qualities. The selection of the preset program Small Parts, Breast or Thyroid was linked with a more detailed contrast of the imaging morphology of facial tissue layers. Frequency (Frq) = 15 MHz, Gain (Gn) = 25–35 db, Depth (D) = 1–1.5 cm, and Focus (F) = 0.5 cm enhanced the image quality and assessability. Conclusions: An optimized HRUS examination protocol for quantitative and qualitative facial muscle assessments was proposed

    Feasibility study of preoperative microvessel evaluation and characterization in perforator flaps using various modes of color-coded duplex sonography (CCDS)

    Get PDF
    Background Color-coded duplex sonography (CCDS) is useful for perforator flap design showing the highest sensitivity in identifying microvessels. This prospective study evaluates the feasibility of different ultrasound (US) modes applied by the microsurgeon in daily practice suggesting quantifiable reference values. Methods Twenty-four patients aged between 17 and 68 years (mean 43.3 +/- 14.2 years) with 18 anterolateral thigh (ALT) and 6 superficial circumflex iliac artery (SCIP) flaps were included. Indications were traumatic (n= 12), infectious (n= 6), ischemic (n= 4), or tumor-associated defects (n= 2). Different US modes were evaluated regarding applicability using multifrequency linear probes (5-15 MHz). Vessels diameter, peak systolic velocity (PSV), end diastolic velocity (EDV), and resistance index (RI) were measured. Preoperative results were correlated to intraoperative findings. Results In the examined patient group with 24 perforator flaps a 100% correlation was seen when comparing perforators detected with CCDS/PD with intraoperative findings using optimized US settings. Sensitivity, PPV, and accuracy of CCDS were 100% respectively. Mean PSV of 16.99 +/- 6.07 cm/s, mean EDV of 5.01 +/- 1.84 cm/s and RI of 0.7 +/- 0.07 were measured in microvessels (PW-mode). CCDS proved to be superior compared to PD in correct diameter assessment showing a mean diameter of 1.65 +/- 0.45 mm, compared to PD-mode 1.31 +/- 0.24 mm. Mean PSV and EDV were higher in ALT than in SCIP flaps, RI was slightly higher in SCIP flaps (p > .05). There were no significant differences in size of different flaps' perforators (p > .05). Conclusion CCDS represents a highly valuable tool in the daily practice of free flap reconstructions using optimized low flow US settings and multifrequency linear probes

    Overall complication rates of DIEP flap breast reconstructions in Germany – a multi-center analysis based on the DGPRÄC prospective national online registry for microsurgical breast reconstructions

    Get PDF
    While autologous breast reconstruction has gained momentum over recent years, there is limited data on the structure and quality of care of microsurgical breast reconstruction in Germany. Using the breast reconstruction database established by the German Society of Plastic, Reconstructive and Aesthetic Surgeons (DGPRÄC), the presented study investigated the overall outcomes of deep inferior epigastric perforator (DIEP) flap reconstructions in Germany. Data of 3926 patients and 4577 DIEP flaps performed by 22 centers were included in this study. Demographics, patient characteristics, perioperative details and postoperative outcomes were accounted for. Centers performing < Ø 40 (low-volume (LV)) vs. ≥ Ø 40 (high-volume (HV)) annual DIEP flaps were analyzed separately. Overall, total and partial flap loss rates were as low as 2.0% and 1.1% respectively, and emergent vascular revision surgery was performed in 4.3% of cases. Revision surgery due to wound complications was conducted in 8.3% of all cases. Mean operative time and length of hospital stay was significantly shorter in the HV group (LV: 385.82 min vs. HV: 287.14 min; LV: 9.04 (18.87) days vs. HV: 8.21 (5.04) days; both p < 0.05). The outcome and complication rates deduced from the national registry underline the high standard of microsurgical breast reconstruction on a national level in Germany

    International expert panel consensus on fat grafting of the breast

    Get PDF
    Background: Autologous fat grafting has broad applications in reconstructive and aesthetic breast surgery as a natural filler and for its regenerative purposes. Despite the widespread use of fat grafting, there remains no shared consensus on what constitutes the optimal fat grafting technique and its oncological safety. For this reason, the authors of this study have organized a Survey and an International Consensus Conference that was held at the Aesthetic Breast Meeting in Milan (December 15, 2018). Methods: All studies on fat grafting, both for breast aesthetic and reconstructive purposes, were electronically screened. The literature review led to 17 "key questions" that were used for the Survey. The authors prepared a set of 10 "key statements" that have been discussed in a dedicated face-to-face session during the meeting. Results: The 10 key statements addressed all the most debated topics on fat grafting of the breast. Levels of evidence for the key statements ranged from III to IV with 2 statements (20%) supported by a level of evidence III and 6 statements (60%) by level of evidence IV. Overall consensus was reached for 2 statements (20%) with >75% agreement reached for 7 statements. Conclusions: The survey demonstrated a diversity of opinion and attitude among the panelists with regard to technique. Clear recommendations for evidence-based clinical practice for fat grafting use both in aesthetic and reconstructive breast surgery could not be defined due to the scarcity of level 1 or 2 studies

    Capsular Biofilm Formation at the Interface of Textured Expanders and Human Acellular Dermal Matrix

    No full text

    The perception bias of aesthetic providers

    No full text

    Was ist globale Chirurgie - Die globale Last der chirurgischen Erkrankungen

    No full text

    Optimizing functional and aesthetic outcomes in post-burn head and neck reconstruction

    No full text
    • …
    corecore