51 research outputs found

    Perceptions and experiences of skilled birth attendants on using a newly developed strap-on electronic fetal heart rate monitor in Tanzania

    Get PDF
    Background: Regular fetal heart rate monitoring during labor can drastically reduce fresh stillbirths and neonatal mortality through early detection and management of fetal distress. Fetal monitoring in low-resource settings is often inadequate. An electronic strap-on fetal heart rate monitor called Moyo was introduced in Tanzania to improve intrapartum fetal heart rate monitoring. There is limited knowledge about how skilled birth attendants in low-resource settings perceive using new technology in routine labor care. This study aimed to explore the attitude and perceptions of skilled birth attendants using Moyo in Dar es Salaam, Tanzania. Methods: A qualitative design was used to collect data. Five focus group discussions and 10 semi-structured indepth interviews were carried out. In total, 28 medical doctors and nurse/midwives participated in the study. The data was analyzed using qualitative content analysis. Results: The participants in the study perceived that the device was a useful tool that made it possible to monitor several laboring women at the same time and to react faster to fetal distress alerts. It was also perceived to improve the care provided to the laboring women. Prior to the introduction of Moyo, the participants described feeling overwhelmed by the high workload, an inability to adequately monitor each laboring woman, and a fear of being blamed for negative fetal outcomes. Challenges related to use of the device included a lack of adherence to routines for use, a lack of clarity about which laboring women should be monitored continuously with the device, and misidentification of maternal heart rate as fetal heart rate. Conclusion: The electronic strap-on fetal heart rate monitor, Moyo, was considered to make labor monitoring easier and to reduce stress. The study findings highlight the importance of ensuring that the device’s functions, its limitations and its procedures for use are well understood by users

    Acquiring Knowledge about the Use of a Newly Developed Electronic Fetal Heart Rate Monitor: A Qualitative Study Among Birth Attendants in Tanzania

    Get PDF
    In an effort to reduce newborn mortality, a newly developed strap-on electronic fetal heart rate monitor was introduced at several health facilities in Tanzania in 2015. Training sessions were organized to teach staff how to use the device in clinical settings. This study explores skilled birth attendants’ perceptions and experiences acquiring and transferring knowledge about the use of the monitor, also called Moyo. Knowledge about this learning process is crucial to further improve training programs and ensure correct, long-term use. Five Focus group discussions (FGDs) were carried out with doctors and nurse-midwives, who were using the monitor in the labor ward at two health facilities in Tanzania. The FGDs were analyzed using qualitative content analysis. The study revealed that the participants experienced the training about the device as useful but inadequate. Due to high turnover, a frequently mentioned challenge was that many of the birth attendants who were responsible for training others, were no longer working in the labor ward. Many participants expressed a need for refresher trainings, more practical exercises and more theory on labor management. The study highlights the need for frequent trainings sessions over time with focus on increasing overall knowledge in labor management to ensure correct use of the monitor over time

    “I Was Relieved to Know That My Baby Was Safe”: Women’s Attitudes and Perceptions on Using a New Electronic Fetal Heart Rate Monitor during Labor in Tanzania

    Get PDF
    To increase labor monitoring and prevent neonatal morbidity and mortality, a new wireless, strap-on electronic fetal heart rate monitor called Moyo was introduced in Tanzania in 2016. As part of the ongoing evaluation of the introduction of the monitor, the aim of this study was to explore the attitudes and perceptions of women who had worn the monitor continuously during their most recent delivery and perceptions about how it affected care. This knowledge is important to identify barriers towards adaptation in order to introduce new technology more effectively. We carried out 20 semi-structured individual interviews post-labor at two hospitals in Tanzania. A thematic content analysis was used to analyze the data. Our results indicated that the use of the monitor positively affected the women’s birth experience. It provided much-needed reassurance about the wellbeing of the child. The women considered that wearing Moyo improved care due to an increase in communication and attention from birth attendants. However, the women did not fully understand the purpose and function of the device and overestimated its capabilities. This highlights the need to improve how and when information is conveyed to women in labor

    Potential causes of early death among admitted newborns in a rural Tanzanian hospital

    Get PDF
    Background: Approximately 40,000 newborns die each year in Tanzania. Regional differences in outcome are common. Reviewing current local data, as well as defining potential causal pathways leading to death are urgently needed, before targeted interventions can be implemented Objective: To describe the clinical characteristics and potential causal pathways contributing to newborn death and determine the presumed causes of newborn mortality within seven days, in a rural hospital setting. Methods: Prospective observational study of admitted newborns born October 2014–July 2017. Information about labour/delivery and newborn management/care were recorded on data collection forms. Causes of deaths were predominantly based on clinical diagnosis. Results: 671 were admitted to a neonatal area. Reasons included prematurity n = 213 (32%), respiratory issues n = 209 (31%), meconium stained amniotic fluid with respiratory issues n = 115 (17%) and observation for \u3c 24 hours n = 97 (14%). Death occurred in 124 infants. Presumed causes were birth asphyxia (BA) n = 59 (48%), prematurity n = 19 (15%), presumed sepsis n = 19 (15%), meconium aspiration syndrome (MAS) n = 13 (10%) and congenital abnormalities n = 14 (11%). More newborns who died versus survivors had oxygen saturation \u3c60% on admission (37/113 vs 32/258; p≤0.001) respectively. Moderate hypothermia on admission was common i.e. deaths 35.1 (34.6–36.0) vs survivors 35.5 (35.0–36.0)°C (p≤0.001). Term newborns who died versus survivors were fourfold more likely to have received positive pressure ventilation after birth i.e. 4.57 (1.22–17.03) (p\u3c0.02). Conclusion: Intrapartum-related complications (BA, MAS), prematurity, and presumed sepsis were the leading causes of death. Intrapartum hypoxia, prematurity and attendant complications and presumed sepsis, are major pathways leading to death. Severe hypoxia and hypothermia upon admission are additional contributing factors. Strategies to identify fetuses at risk during labour e.g. improved fetal heart rate monitoring, coupled with timely interventions, and implementation of WHO interventions for preterm newborns, may reduce mortality in this low resource setting

    Predictors of death including quality of positive pressure ventilation during newborn resuscitation and the relationship to outcome at seven days in a rural Tanzanian hospital

    Get PDF
    Background Effective positive pressure ventilation (PPV) of non-breathing newborns is crucial in facilitating cardio-respiratory adaptation at birth. Identifying predictors of death in newborns receiving PPV is important in order to facilitate preventative strategies. Objective The objective of this study was to determine the perinatal predictors of death including the quality of PPV administered among admitted newborns. Methods An observational study of admitted newborns who received PPV after birth was conducted. Research assistants observed all deliveries and recorded perinatal events on data collection forms. Measured heart rate (HR) and ventilation parameters were then compared between newborns who died and survivors. Results Newborns (n = 232) were studied between October 2014 and November 2016. Newborns who died (n = 53) compared to survivors (n = 179) had more fetal heart rate (FHRT) abnormalities (12/53 vs 19/179; p = 0.03); lower initial HR (/minute) at start of PPV (44/48 vs 77/139; p100 beats/minute from birth (180 vs 149 seconds; p = 0.07). Newborns who died compared to survivors took longer time (14 vs 4 seconds; p = 0.008) and more inflations (7 vs 3; p = 0.006) to achieve an expired volume (Vt) of 6 ml/kg, respectively. Median delivered Vt during the first 60 seconds of PPV was less in newborns who died compared to survivors (5 vs 6 ml/kg; p = 0.12). Newborns who died proceeded to severe encephalopathy (15/31 vs 1/59; p Conclusion Depressed newborns who proceeded to death compared to survivors, exhibited delayed HR response to PPV which may partly reflect FHRT abnormalities related to interruption of placental blood flow, and/or a timely delay in establishing adequate Vt. Depressed newborns progressed to moderate/severe encephalopathy. Improving FHRT monitoring to identify fetuses at risk for expedited delivery, coupled with optimizing delivery room PPV might decrease mortality in this setting

    Video Analysis of Newborn Resuscitations After Simulation-Based Helping Babies Breathe Training

    Get PDF
    Background: Simulation-based Helping Babies Breathe (HBB) training is currently rolled-out in around 80 low-income countries with various results. Method: Workflow was analyzed in 76 video-recorded newborn resuscitations performed by regularly HBB-trained nurse-midwives over 3 years in rural Tanzania. Results: Actual newborn resuscitation practice deviated from HBB intention/guideline: most newborns underwent prolonged suction and stimulation before ventilation; ventilation was delayed and frequently interrupted. Nurse-midwives often worked together. Conclusions:There is a gap between training intention and clinical practice. HBB trainings should focus more on urgency, ventilation skills, and team training. Combining clinical debriefing with HBB simulations could facilitate continuous learning and applicatio

    Implementation of a novel continuous fetal Doppler (Moyo) improves quality of intrapartum fetal heart rate monitoring in a resource-limited tertiary hospital in Tanzania: An observational study

    Get PDF
    Background Intrapartum Fetal Heart Rate (FHR) monitoring is crucial for the early detection of abnormal FHR, facilitating timely obstetric interventions and thus the potential reduction of adverse perinatal outcomes. We explored midwifery practices of intrapartum FHR monitoring pre and post implementation of a novel continuous automatic Doppler device (the Moyo). Methodology A pre/post observational study among low-risk pregnancies at a tertiary hospital was conducted from March to December 2016. In the pre-implementation period, intermittent monitoring was conducted with a Pinard stethoscope (March to June 2016, n = 1640 women). In the post-implementation period, Moyo was used for continuous FHR monitoring (July-December 2016, n = 2442 women). The primary outcome was detection of abnormal FHR defined as absent, FHR160bpm. The secondary outcomes were rates of assessment/documentation of FHR, obstetric time intervals and intrauterine resuscitations. Chi-square test, Fishers exact test, t-test and Mann-Whitney U test were used in bivariate analysis whereas binary and multinomial logistic regression were used for multivariate. Results Moyo use was associated with greater detection of abnormal FHR (8.0%) compared with Pinard (1.6%) (p Conclusion Implementation of the Moyo device, which continuously measures FHR, was associated with improved quality in FHR monitoring practices and the detection of abnormal FHR. These improvements led to more frequent and timely obstetric responses. Follow-up studies in a high-risk population focused on a more targeted description of the FHR abnormalities and the impact of intrauterine resuscitation is a critical next step in determining the effect on reducing perinatal mortality

    Video Analysis of Newborn Resuscitations After Simulation-Based Helping Babies Breathe Training

    Get PDF
    Background Simulation-based Helping Babies Breathe (HBB) training is currently rolled-out in around 80 low-income countries with various results. Method Workflow was analyzed in 76 video-recorded newborn resuscitations performed by regularly HBB-trained nurse-midwives over 3 years in rural Tanzania. Results Actual newborn resuscitation practice deviated from HBB intention/guideline: most newborns underwent prolonged suction and stimulation before ventilation; ventilation was delayed and frequently interrupted. Nurse-midwives often worked together. Conclusions There is a gap between training intention and clinical practice. HBB trainings should focus more on urgency, ventilation skills, and team training. Combining clinical debriefing with HBB simulations could facilitate continuous learning and application.publishedVersio

    Virtual reality simulation training in stroke thrombectomy centers with limited patient volume—Simulator performance and patient outcome

    Get PDF
    Background Virtual reality simulation training may improve the technical skills of interventional radiologists when establishing endovascular thrombectomy at limited-volume stroke centers. The aim of this study was to investigate whether the technical thrombectomy performance of interventional radiologists improved after a defined virtual reality simulator training period. As part of the quality surveillance of clinical practice, we also assessed patient outcomes and thrombectomy quality indicators at the participating centers. Methods Interventional radiologists and radiology residents from three thrombectomy-capable stroke centers participated in a five months thrombectomy skill-training curriculum on a virtual reality simulator. The simulator automatically registered procedure time, the number of predefined steps that were correctly executed, handling errors, contrast volume, fluoroscopy time, and radiation dose exposure. The design was a before-after study. Two simulated thrombectomy cases were used as pretest and posttest cases, while seven other cases were used for training. Utilizing the Norwegian Stroke Register, we investigated clinical results in thrombectomy during the study period. Results Nineteen interventional radiologists and radiology residents participated in the study. The improvement between pretest and posttest cases was statistically significant for all outcome measures in both simulated cases, except for the contrast volume used in one case. Clinical patient outcomes in all three centers were well within the recommendations from multi-society consensus guidelines. Conclusion Performance on the virtual reality simulator improved after training. Virtual reality simulation may improve the learning curve for interventional radiologists in limited-volume thrombectomy centers. No correlation alleged, the clinical data indicates that the centers studied performed thrombectomy in accordance with guideline-recommended standards.publishedVersio
    corecore