28 research outputs found
Recommended from our members
Morpho-molecular ex vivo detection and grading of non-muscle-invasive bladder cancer using forward imaging probe based multimodal optical coherence tomography and Raman spectroscopy
Non-muscle-invasive bladder cancer affects millions of people worldwide, resulting in significant discomfort to the patient and potential death. Today, cystoscopy is the gold standard for bladder cancer assessment, using white light endoscopy to detect tumor suspected lesion areas, followed by resection of these areas and subsequent histopathological evaluation. Not only does the pathological examination take days, but due to the invasive nature, the performed biopsy can result in significant harm to the patient. Nowadays, optical modalities, such as optical coherence tomography (OCT) and Raman spectroscopy (RS), have proven to detect cancer in real time and can provide more detailed clinical information of a lesion, e.g. its penetration depth (stage) and the differentiation of the cells (grade). In this paper, we present an ex vivo study performed with a combined piezoelectric tube-based OCT-probe and fiber optic RS-probe imaging system that allows large field-of-view imaging of bladder biopsies, using both modalities and co-registered visualization, detection and grading of cancerous bladder lesions. In the present study, 119 examined biopsies were characterized, showing that fiber-optic based OCT provides a sensitivity of 78% and a specificity of 69% for the detection of non-muscle-invasive bladder cancer, while RS, on the other hand, provides a sensitivity of 81% and a specificity of 61% for the grading of low- and high-grade tissues. Moreover, the study shows that a piezoelectric tube-based OCT probe can have significant endurance, suitable for future long-lasting in vivo applications. These results also indicate that combined OCT and RS fiber probe-based characterization offers an exciting possibility for label-free and morpho-chemical optical biopsies for bladder cancer diagnostics. © 2020 The Royal Society of Chemistry
Cross sectional imaging of truncal and quadriceps muscles relates to different functional outcomes in cancer
Introduction:
Following the consensus definition of cancer cachexia, more studies are using CT scan analysis of truncal muscles as a marker of muscle wasting. However, how CT-derived body composition relates to function, strength and power in patients with cancer is largely unknown.
Aims:
We aimed to describe the relationship between CT truncal (L3) skeletal muscle index (SMI) and MRI quadriceps cross sectional area with lower limb strength, power and measures of complex function.
Methods:
Patients undergoing assessment for potentially curative surgery for oesophagogastric or pancreatic cancer were recruited from the regional upper gastrointestinal (UGI) or hepatopancreaticobiliary (HPB) multi-disciplinary team meetings. Maximum Isometric Knee Extensor Strength (IKES) and Maximum Leg Extensor Power (Nottingham Power Rig) (LEP) were used as measures of lower limb performance. Both Sit to Stand (STS) and Timed Up and Go (TUG) were used as measures of global complex muscle function. Muscle SMI was measured from routine CT scans at the level of the third lumbar vertebrae (L3) and MRI scan was used for the assessment of quadriceps muscles. Linear regression analysis was performed for CT SMI or MRI quadriceps as a predictor of each measure of performance.
Results:
Forty-four patients underwent assessment. Height and weight were significantly related to function in terms of quadriceps power, while only weight was associated with strength (P < 0.001). CT SMI was not related to measures of quadriceps strength or power but had significant association with more complex functional measures (P = 0.006, R2 = 0.234 and 0.0019, R2 = 0.175 for STS and TUG respectively). In comparison, both gross and fat-subtracted measures of quadriceps muscle mass from MRI were significantly correlated with quadriceps strength and power (P < 0.001), but did not show any significant association with complex functional measures.
Conclusion:
CT SMI and MRI quadriceps have been shown to reflect different aspects of functional ability with CT SMI being a marker of global muscle function and MRI quadriceps being specific to quadriceps power and strength. This should therefore be considered when choosing outcome measures for trials or definitions of muscle mass and function
Tumour-reactive T cell subsets in the microenvironment of ovarian cancer.
Solid malignancies are frequently infiltrated with T cells. The success of adoptive cell transfer (ACT) with expanded tumour-infiltrating lymphocytes (TILs) in melanoma warrants its testing in other cancer types. In this preclinical study, we investigated whether clinical-grade TILs could be manufactured from ovarian cancer (OC) tumour specimens.
Thirty-four tumour specimens were obtained from 33 individual patients with OC. TILs were analysed for phenotype, antigen specificity and functionality.
Minimally expanded TILs (Young TILs) were successfully established from all patients. Young TILs contained a high frequency of CD3 <sup>+</sup> cells with a variable CD4/CD8 ratio. TILs could be expanded to clinical numbers. Importantly, recognition of autologous tumour cells was demonstrated in TILs in >50% of the patients. We confirmed with mass spectrometry the presentation of multiple tumour antigens, including peptides derived from the cancer-testis antigen GAGE, which could be recognised by antigen-specific TILs. Antigen-specific TILs could be isolated and further expanded in vitro.
These findings support the hypothesis that patients with OC can benefit from ACT with TILs and led to the initiation of a pilot clinical trial at our institution .
clinicaltrials.gov: NCT02482090
Correction: Tumour-reactive T cell subsets in the microenvironment of ovarian cancer.
Since the publication of this paper, the authors noticed that the funding information was not complete. The correct funding information is now shown in the Acknowledgements section. Acknowledgements The studies were supported by grants from the OvaCure Foundation, the Danish Cancer Society Research Foundation, the Anticancer Fund, Aase og Ejnar Danielsens Foundation and the Independent Research Fund Denmark (grant number DFF-4183-00597)
Morpho-molecular ex vivo detection and grading of non-muscle-invasive bladder cancer using forward imaging probe based multimodal optical coherence tomography and Raman spectroscopy
Non-muscle-invasive bladder cancer affects millions of people worldwide, resulting in significant discomfort to the patient and potential death. Today, cystoscopy is the gold standard for bladder cancer assessment, using white light endoscopy to detect tumor suspected lesion areas, followed by resection of these areas and subsequent histopathological evaluation. Not only does the pathological examination take days, but due to the invasive nature, the performed biopsy can result in significant harm to the patient. Nowadays, optical modalities, such as optical coherence tomography (OCT) and Raman spectroscopy (RS), have proven to detect cancer in real time and can provide more detailed clinical information of a lesion, e.g. its penetration depth (stage) and the differentiation of the cells (grade). In this paper, we present an ex vivo study performed with a combined piezoelectric tube-based OCT-probe and fiber optic RS-probe imaging system that allows large field-of-view imaging of bladder biopsies, using both modalities and co-registered visualization, detection and grading of cancerous bladder lesions. In the present study, 119 examined biopsies were characterized, showing that fiber-optic based OCT provides a sensitivity of 78% and a specificity of 69% for the detection of non-muscle-invasive bladder cancer, while RS, on the other hand, provides a sensitivity of 81% and a specificity of 61% for the grading of low- and high-grade tissues. Moreover, the study shows that a piezoelectric tube-based OCT probe can have significant endurance, suitable for future long-lasting in vivo applications. These results also indicate that combined OCT and RS fiber probe-based characterization offers an exciting possibility for label-free and morpho-chemical optical biopsies for bladder cancer diagnostics