928 research outputs found
Clyde tributaries : report of urban stream sediment and surface water geochemistry for Glasgow
This report presents the results of an urban drainage geochemical survey carried out jointly by the British Geological Survey (BGS) and Glasgow City Council (GCC) during June 2003. 118 stream sediment and 122 surface water samples were collected at a sample density of 1 per 1 km2 from all tributaries draining into the River Clyde within the GCC administrative area. The study was carried out as part of the BGS systematic Geochemical Surveys of Urban Environments (GSUE) programme.
Stream sediment and surface water samples underwent analysis for approximately 46 chemical elements including contaminants such as As, Al, Cd, Cu, Cr, Ni, Pb, Se, V and Zn according to standard GSUE procedures. In addition, parameters such as ammonium, asbestos and Hg as well as organic contaminants such as total petroleum hydrocarbons (TPH), polycyclic aromatic hydrocarbons (PAH), poly-chlorinated biphenyls (PCB) and organo-tin compounds were assessed.
The aim of the project was to provide an overview of urban drainage geochemistry in Glasgow to link to an on-going sister project, which is investigating the geochemistry of the Clyde estuary. This report presents the initial findings of the Clyde tributaries survey but it is envisaged that the data will be interpreted in more detail as part of a wider Clyde basin study once the Clyde estuary survey is completed
Total joint replacement in sub-Saharan Africa:a systematic review
Outcomes of arthroplasty in sub-Saharan Africa are not widely reported. To our knowledge, this systematic review is the first to explore this topic. Scopus, EMBASE, Medline and PubMed databases were searched, utilising MeSH headings and Boolean search strategies. All papers from South Africa were excluded. Twelve papers reporting 606 total hip replacements (THRs) and 763 total knee replacements (TKRs) were included. Avascular necrosis was the most common indication for THR, whereas osteoarthritis was the main indication for TKR. HIV prevalence of up to 33% was seen. Improvements were seen in patient-reported outcome measures in both THR and TKR. The dislocation rate in THR was 1.6%. The deep infection rate was 1.6% for TKRs and 0.5% for THRs. Positive results were reported, with comparable complications to high-income countries. However, there is likely to be significant reporting bias and the introduction of mandatory registries would enable more accurate monitoring across the region
Recommended from our members
An assessment of a three-beam Doppler lidar wind profiling method for use in urban areas
Currently there are few observations of the urban wind field at heights other than rooftop level. Remote sensing instruments such as Doppler lidars provide wind speed data at many heights, which would be useful in determining wind loadings of tall buildings, and predicting local air quality. Studies comparing remote sensing with traditional anemometers carried out in flat, homogeneous terrain often use scan patterns which take several minutes. In an urban context the flow changes quickly in space and time, so faster scans are required to ensure little change in the flow over the scan period. We compare 3993 h of wind speed data collected using a three-beam Doppler lidar wind profiling method with data from a sonic anemometer (190 m). Both instruments are located in central London, UK; a highly built-up area. Based on wind profile measurements every 2 min, the uncertainty in the hourly mean wind speed due to the sampling frequency is 0.05â0.11 m sâ1. The lidar tended to overestimate the wind speed by â0.5 m sâ1 for wind speeds below 20 m sâ1. Accuracy may be improved by increasing the scanning frequency of the lidar. This method is considered suitable for use in urban areas
Thromboelastometry and Platelet Function during Acclimatization to High Altitude
Interaction between hypoxia and coagulation is important given the increased risk of thrombotic diseases in chronically hypoxic patients who reside at sea level and in residents at high altitude. Hypoxia alters the proteome of platelets favouring a prothrombotic phenotype, but studies of activation and consumption of specific coagulation factors in hypoxic humans have yielded conflicting results. We tested blood from 63 healthy lowland volunteers acclimatizing to high altitude (5,200 m) using thromboelastometry and assays of platelet function to examine the effects of hypoxia on haemostasis. Using data from two separate cohorts of patients following identical ascent profiles, we detected a significant delay in clot formation, but increased clot strength by day 7 at 5,200 m. The latter finding may be accounted for by the significant rise in platelet count and fibrinogen concentration that occurred during acclimatization. Platelet function assays revealed evidence of platelet hyper-reactivity, with shortened PFA-100 closure times and increased platelet aggregation in response to adenosine diphosphate. Post-expedition results were consistent with the normalization of coagulation following descent to sea level. These robust findings indicate that hypoxia increases platelet reactivity and, with the exception of the paradoxical delay in thromboelastometry clotting time, suggest a prothrombotic phenotype at altitude. Further work to elucidate the mechanism of platelet activation in hypoxia will be important and could impact upon the management of patients with acute or chronic hypoxic respiratory diseases who are at risk of thrombotic events.
Erratum to: Thromboelastometry and platelet function during acclimatisation to high altitude (doi: 10.1160/TH17-02-0138) http://eprints.whiterose.ac.uk/129510/
In the Original Article by Rocke et al. âThromboelastometry and platelet function during acclimatization to high altitudeâ (Thromb Haemost 2018; 118: 063-071) after publication of the article it has come to the corresponding author's attention that an author was inadvertently omitted from the manuscript. The author, Martin MacInnis, made a significant contribution to: 1. initiating the coagulation research that led to the manuscript, 2. designing the research protocol and performing the initial data analysis, 3. recruiting volunteers, writing applications for ethical approval and making other logistical arrangements that were necessary to complete the study. Martin MacInnis has read and approved the published version of the manuscript. Furthermore, a middle initial was added to the updated list (Shona E. Main) and misspelling of Elizabeth Horn's surname was corrected. The amended author list is as above. https://doi.org
Observations of Coronal Mass Ejections with the Coronal Multichannel Polarimeter
The Coronal Multichannel Polarimeter (CoMP) measures not only the
polarization of coronal emission, but also the full radiance profiles of
coronal emission lines. For the first time, CoMP observations provide
high-cadence image sequences of the coronal line intensity, Doppler shift and
line width simultaneously in a large field of view. By studying the Doppler
shift and line width we may explore more of the physical processes of CME
initiation and propagation. Here we identify a list of CMEs observed by CoMP
and present the first results of these observations. Our preliminary analysis
shows that CMEs are usually associated with greatly increased Doppler shift and
enhanced line width. These new observations provide not only valuable
information to constrain CME models and probe various processes during the
initial propagation of CMEs in the low corona, but also offer a possible
cost-effective and low-risk means of space weather monitoring.Comment: 6 figures. Will appear in the special issue of Coronal Magnetism,
Sol. Phy
Coronal Diagnostics from Narrowband Images around 30.4 nm
Images taken in the band centered at 30.4 nm are routinely used to map the
radiance of the He II Ly alpha line on the solar disk. That line is one of the
strongest, if not the strongest, line in the EUV observed in the solar
spectrum, and one of the few lines in that wavelength range providing
information on the upper chromosphere or lower transition region. However, when
observing the off-limb corona the contribution from the nearby Si XI 30.3 nm
line can become significant. In this work we aim at estimating the relative
contribution of those two lines in the solar corona around the minimum of solar
activity. We combine measurements from CDS taken in August 2008 with
temperature and density profiles from semiempirical models of the corona to
compute the radiances of the two lines, and of other representative coronal
lines (e.g., Mg X 62.5 nm, Si XII 52.1 nm). Considering both diagnosed
quantities from line ratios (temperatures and densities) and line radiances in
absolute units, we obtain a good overall match between observations and models.
We find that the Si XI line dominates the He II line from just above the limb
up to ~2 R_Sun in streamers, while its contribution to narrowband imaging in
the 30.4 nm band is expected to become smaller, even negligible in the corona
beyond ~2 - 3 R_Sun, the precise value being strongly dependent on the coronal
temperature profile.Comment: 26 pages, 11 figures; to be published in: Solar Physic
A NuSTAR Survey of Nearby Ultraluminous Infrared Galaxies
We present a Nuclear Spectroscopic Telescope Array (NuSTAR), Chandra, and XMM-Newton survey of nine of the nearest ultraluminous infrared galaxies (ULIRGs). The unprecedented sensitivity of NuSTAR at energies above 10 keV enables spectral modeling with far better precision than was previously possible. Six of the nine sources observed were detected sufficiently well by NuSTAR to model in detail their broadband X-ray spectra, and recover the levels of obscuration and intrinsic X-ray luminosities. Only one source (IRAS 13120â5453) has a spectrum consistent with a Compton-thick active galactic nucleus (AGN), but we cannot rule out that a second source (Arp 220) harbors an extremely highly obscured AGN as well. Variability in column density (reduction by a factor of a few compared to older observations) is seen in IRAS 05189â2524 and Mrk 273, altering the classification of these borderline sources from Compton-thick to Compton-thin. The ULIRGs in our sample have surprisingly low observed fluxes in high-energy (>10 keV) X-rays, especially compared to their bolometric luminosities. They have lower ratios of unabsorbed 2â10 keV to bolometric luminosity, and unabsorbed 2â10 keV to mid-IR [O iv] line luminosity than do Seyfert 1 galaxies. We identify IRAS 08572+3915 as another candidate intrinsically X-ray weak source, similar to Mrk 231. We speculate that the X-ray weakness of IRAS 08572+3915 is related to its powerful outflow observed at other wavelengths
The Phoenix galaxy as seen by NuSTAR
Aims. We study the long-term variability of the well-known Seyfert 2 galaxy Mrk 1210 (a.k.a. UGC 4203, or the Phoenix galaxy). Methods. The source was observed by many X-ray facilities in the last 20 years. Here we present a NuSTAR observation and put the results in context of previously published observations. Results. NuSTAR observed Mrk 1210 in 2012 for 15.4 ks. The source showed Compton-thin obscuration similar to that observed by Chandra, Suzaku, BeppoSAX and XMM-Newton over the past two decades, but different from the first observation by ASCA in 1995, in which the active nucleus was caught in a low flux state - or obscured by Compton-thick matter, with a reflection-dominated spectrum. Thanks to the high-quality hard X-ray spectrum obtained with NuSTAR and exploiting the long-term spectral coverage spanning 16.9 years, we can precisely disentangle the transmission and reflection components and put constraints on both the intrinsic long-term variability and hidden nucleus scenarios. In the former case, the distance between the reflector and the source must be at least ~ 2 pc, while in the latter one the eclipsing cloud may be identified with a water maser-emitting clump.<br/
NuSTAR unveils a Compton-thick type 2 quasar in MrK 34
We present Nuclear Spectroscopic Telescope Array (NuSTAR) 3-40 keV observations of the optically selected Type 2 quasar (QSO2) SDSS J1034+6001 or Mrk 34. The high-quality hard X-ray spectrum and archival XMM-Newton data can be fitted self-consistently with a reflection-dominated continuum and a strong Fe K? fluorescence line with equivalent width >1 keV. Prior X-ray spectral fitting below 10 keV showed the source to be consistent with being obscured by Compton-thin column densities of gas along the line of sight, despite evidence for much higher columns from multiwavelength data. NuSTAR now enables a direct measurement of this column and shows that N H lies in the Compton-thick (CT) regime. The new data also show a high intrinsic 2-10 keV luminosity of L 2-10 ~ 1044 erg sâ1, in contrast to previous low-energy X-ray measurements where L 2-10 lesssim 1043 erg sâ1 (i.e., X-ray selection below 10 keV does not pick up this source as an intrinsically luminous obscured quasar). Both the obscuring column and the intrinsic power are about an order of magnitude (or more) larger than inferred from pre-NuSTAR X-ray spectral fitting. Mrk 34 is thus a "gold standard" CT QSO2 and is the nearest non-merging system in this class, in contrast to the other local CT quasar NGC 6240, which is currently undergoing a major merger coupled with strong star formation. For typical X-ray bolometric correction factors, the accretion luminosity of Mrk 34 is high enough to potentially power the total infrared luminosity. X-ray spectral fitting also shows that thermal emission related to star formation is unlikely to drive the observed bright soft component below ~3 keV, favoring photoionization instead
NuSTAR J033202-2746.8: Direct Constraints on the Compton Reflection in a Heavily Obscured Quasar at z â 2
We report Nuclear Spectroscopic Telescope Array (NuSTAR) observations of NuSTAR J033202-2746.8, a heavily obscured, radio-loud quasar detected in the Extended Chandra Deep Field-South, the deepest layer of the NuSTAR extragalactic survey (~400 ks, at its deepest). NuSTAR J033202-2746.8 is reliably detected by NuSTAR only at E > 8 keV and has a very flat spectral slope in the NuSTAR energy band (; 3-30 keV). Combining the NuSTAR data with extremely deep observations by Chandra and XMM-Newton (4 Ms and 3 Ms, respectively), we constrain the broad-band X-ray spectrum of NuSTAR J033202-2746.8, indicating that this source is a heavily obscured quasar ( cmâ2) with luminosity L 10-40 keV â 6.4 Ă 1044 erg sâ1. Although existing optical and near-infrared (near-IR) data, as well as follow-up spectroscopy with the Keck and VLT telescopes, failed to provide a secure redshift identification for NuSTAR J033202-2746.8, we reliably constrain the redshift z = 2.00 ± 0.04 from the X-ray spectral features (primarily from the iron K edge). The NuSTAR spectrum shows a significant reflection component (), which was not constrained by previous analyses of Chandra and XMM-Newton data alone. The measured reflection fraction is higher than the R ~ 0 typically observed in bright radio-loud quasars such as NuSTAR J033202-2746.8, which has L 1.4 GHz â 1027 W Hzâ1. Constraining the spectral shape of active galactic nuclei (AGNs), including bright quasars, is very important for understanding the AGN population, and can have a strong impact on the modeling of the X-ray background. Our results show the importance of NuSTAR in investigating the broad-band spectral properties of quasars out to high redshift
- âŠ