4,192 research outputs found

    A Model of Tuberculosis Screening for Pregnant Women in Resource-Limited Settings Using Xpert MTB/RIF

    Get PDF
    Timely diagnosis and treatment of maternal tuberculosis (TB) is important to reduce morbidity and mortality for both the mother and child, particularly in women who are coinfected with HIV. The World Health Organization (WHO) recommends the integration of TB/HIV screening into antenatal services but available diagnostic tools are slow and insensitive, resulting in delays in treatment initiation. Recently the WHO endorsed Xpert MTB/RIF, a highly sensitive, real-time PCR assay for Mycobacterium tuberculosis that simultaneously detects rifampicin resistance directly from sputum and provides results within 100 minutes. We propose a model for same-day TB screening and diagnosis of all pregnant women at antenatal care using Xpert MTB/RIF. Pilot studies are urgently required to evaluate strategies for the integration of TB screening into antenatal clinics using new diagnostic technologies

    A model of tuberculosis screening for pregnant women in resource-limited settings using Xpert MTB/RIF

    Get PDF
    Timely diagnosis and treatment of maternal tuberculosis (TB) is important to reduce morbidity and mortality for both the mother and child, particularly in women who are coinfected with HIV. TheWorld Health Organization (WHO) recommends the integration of TB/HIV screening into antenatal services but available diagnostic tools are slow and insensitive, resulting in delays in treatment initiation. Recently the WHO endorsed Xpert MTB/RIF, a highly sensitive, real-time PCR assay for Mycobacterium tuberculosis that simultaneously detects rifampicin resistance directly from sputum and provides results within 100 minutes. We propose a model for same-day TB screening and diagnosis of all pregnant women at antenatal care using Xpert MTB/RIF. Pilot studies are urgently required to evaluate strategies for the integration of TB screening into antenatal clinics using new diagnostic technologies

    A Model of Tuberculosis Screening for Pregnant Women in Resource-Limited Settings Using Xpert MTB/RIF

    Get PDF
    Timely diagnosis and treatment of maternal tuberculosis (TB) is important to reduce morbidity and mortality for both the mother and child, particularly in women who are coinfected with HIV. The World Health Organization (WHO) recommends the integration of TB/HIV screening into antenatal services but available diagnostic tools are slow and insensitive, resulting in delays in treatment initiation. Recently the WHO endorsed Xpert MTB/RIF, a highly sensitive, real-time PCR assay for Mycobacterium tuberculosis that simultaneously detects rifampicin resistance directly from sputum and provides results within 100 minutes. We propose a model for same-day TB screening and diagnosis of all pregnant women at antenatal care using Xpert MTB/RIF. Pilot studies are urgently required to evaluate strategies for the integration of TB screening into antenatal clinics using new diagnostic technologies

    An Evaluation of the Performance and Acceptability of Three LED Fluorescent Microscopes in Zambia: Lessons Learnt for Scale-Up

    Get PDF
    The World Health Organization recommends the roll-out of light-emitting diode (LED) fluorescent microscopes (FM) as an alternative to light microscopes in resource-limited settings. We evaluated the acceptability and performance of three LED FMs after a short orientation among laboratory technicians from government health centers in Zambia. Sixteen technicians with varied light microscopy experience were oriented to FMs and divided into groups; each group read a different set of 40 slides on each LED FM (Primo Star iLED™, Lumin™, FluoLED™) and on a reference mercury-vapor FM (Olympus BX41TF). Slide reading times were recorded. An experienced FM technician examined each slide on the Olympus BX41TF. Sensitivity and specificity compared to TB culture were calculated. Misclassification compared to the experienced technician and inter-rater reliability between trainees was assessed. Trainees rated microscopes on technical aspects. Primo Star iLED™, FluoLED™ and Olympus BX41TF had comparable sensitivities (67%, 65% and 65% respectively), with the Lumin™ significantly worse (56%; p<0.05). Specificity was low for trainees on all microscopes (75.9%) compared to the experienced technician on Olympus BX41TF (100%). Primo Star iLED™ had significantly less misclassification (21.1% p<0.05) than FluoLED™ (26.5%) and Lumin™ (26.8%) and significantly higher inter-rater reliability (0.611; p<0.05), compared to FluoLED™ (0.523) and Lumin™ (0.492). Slide reading times for LED FMs were slower than the reference, but not significantly different from each other. Primo Star iLED™ rated highest in acceptability measures, followed by FluoLED™ then Lumin™. Primo Star iLED™ was consistently better than FluoLED™ and Lumin™, and performed comparably to the Olympus BX41TF in all analyses, except reading times. The Lumin™ compared least favorably and was thought unacceptable for use. Specificity and inter-rater reliability were low for all microscopes suggesting that a brief orientation was insufficient in this setting. These results provide important data for resource-limited settings to consider as they scale-up LED FMs

    Development of a generic activities model of command and control

    Get PDF
    This paper reports on five different models of command and control. Four different models are reviewed: a process model, a contextual control model, a decision ladder model and a functional model. Further to this, command and control activities are analysed in three distinct domains: armed forces, emergency services and civilian services. From this analysis, taxonomies of command and control activities are developed that give rise to an activities model of command and control. This model will be used to guide further research into technological support of command and control activities

    Wake up, wake up! It's me! It's my life! patient narratives on person-centeredness in the integrated care context: a qualitative study

    Get PDF
    Person-centered care emphasizes a holistic, humanistic approach that puts patients first, at the center of medical care. Person-centeredness is also considered a core element of integrated care. Yet typologies of integrated care mainly describe how patients fit within integrated services, rather than how services fit into the patient's world. Patient-centeredness has been commonly defined through physician's behaviors aimed at delivering patient-centered care. Yet, it is unclear how 'person-centeredness' is realized in integrated care through the patient voice. We aimed to explore patient narratives of person-centeredness in the integrated care context

    Cannabinoid use and effects in patients with epidermolysis bullosa:an international cross-sectional survey study

    Get PDF
    Abstract Background Epidermolysis bullosa (EB) patient anecdotes and case reports indicate that cannabinoid-based medicines (CBMs) may alleviate pain and pruritus and improve wound healing. CBM use has not been characterized in the EB patient population. Objectives To evaluate CBM use among EB patients, including CBM types, effects on symptoms (e.g., pain and pruritus), disease process (e.g., blistering, wounds, and inflammation), well-being (e.g., sleep, appetite) and concomitant medications. Methods English-speaking EB patients or caregivers completed an online international, anonymous, cross-sectional survey regarding CBM use. Respondents reported the types of CBMs, subsequent effects including perceived EB symptom alteration, changes in medication use, and side effects. Results Seventy-one EB patients from five continents reported using or having used CBMs to treat their EB. Missing question responses ranged between 0 (0%) and 33 (46%). Most used more than one CBM preparation (mean: 2.4 ± 1.5) and route of administration (mean: 2.1 ± 1.1). Topical and ingested were the most common routes. Pain and pruritus were reported retrospectively to decrease by 3 points (scale: 0–10; p < 0.001 for both) after CBM use. Most reported that CBM use improved their overall EB symptoms (95%), pain (94%), pruritus (91%) and wound healing (81%). Most participants (79%) reported decreased use of pain medications. The most common side-effect was dry mouth (44%). Conclusions CBMs improve the perception of pain, pruritus, wound healing, and well-being in EB patients and reduced concomitant medication use. Nevertheless, a direct relation between the use of CBMs and reduction of the above-mentioned symptoms cannot be proven by these data. Therefore, future controlled studies using pharmaceutically standardised CBM preparations in EB are warranted to delineate the risks and benefits of CBMs

    Screening for tuberculosis and testing for human immunodeficiency virus in Zambian prisons

    Get PDF
    Objective: To improve the Zambia Prisons Service's implementation of tuberculosis screening and human immunodeficiency virus (HIV) testing. Methods: For both tuberculosis and HIV, we implemented mass screening of inmates and community-based screening of those residing in encampments adjacent to prisons. We also established routine systems – with inmates as peer educators – for the screening of newly entered or symptomatic inmates. We improved infection control measures, increased diagnostic capacity and promoted awareness of tuberculosis in Zambia's prisons. Findings: In a period of 9 months, we screened 7638 individuals and diagnosed 409 new patients with tuberculosis. We tested 4879 individuals for HIV and diagnosed 564 cases of infection. An additional 625 individuals had previously been found to be HIV-positive. Including those already on tuberculosis treatment at the time of screening, the prevalence of tuberculosis recorded in the prisons and adjacent encampments – 6.4% (6428/100 000) – is 18 times the national prevalence estimate of 0.35%. Overall, 22.9% of the inmates and 13.8% of the encampment residents were HIV-positive. Conclusion: Both tuberculosis and HIV infection are common within Zambian prisons. We enhanced tuberculosis screening and improved the detection of tuberculosis and HIV in this setting. Our observations should be useful in the development of prison-based programmes for tuberculosis and HIV elsewhere

    Does Stellar Feedback Create HI Holes? An HST/VLA Study of Holmberg II

    Full text link
    We use deep HST/ACS F555W and F814W photometry of resolved stars in the M81 Group dwarf irregular galaxy Ho II to study the hypothesis that the holes identified in the neutral ISM (HI) are created by stellar feedback. From the deep photometry, we construct color-magnitude diagrams (CMDs) and measure the star formation histories (SFHs) for stars contained in HI holes from two independent holes catalogs, as well as select control fields, i.e., similar sized regions that span a range of HI column densities. Converting the recent SFHs into stellar feedback energies, we find that enough energy has been generated to have created all holes. However, the required energy is not always produced over a time scale that is less than the estimated kinematic age of the hole. The combination of the CMDs, recent SFHs, and locations of young stars shows that the stellar populations inside HI holes are not coherent, single-aged, stellar clusters, as previously suggested, but rather multi-age populations distributed across each hole. From a comparison of the modeled and observed integrated magnitudes, and the locations and energetics of stars inside of HI holes, we propose a potential new model: a viable mechanism for creating the observed HI holes in Ho II is stellar feedback from multiple generations of SF spread out over tens or hundreds of Myr, and thus, the concept of an age for an HI hole is intrinsically ambiguous. We further find that \halpha and 24 micron emission, tracers of the most recent star formation, do not correlate well with the positions of the HI holes. However, UV emission, which traces star formation over roughly the last 100 Myr, shows a much better correlation with the locations of the HI holes.Comment: Accepted for Publication in The Astrophysical Journal; 28 Pages, 31 Figures, a version of this paper with full resolution figures is available at http://homepages.spa.umn.edu/~dweisz/ho_ii_weisz.pd
    corecore