26 research outputs found

    Predicting flux decline of reverse osmosis membranes

    Get PDF
    A mathematical model predicting flux decline of reverse osmosis membranes due to colloidal fouling has been verified. This mathema- tical model is based on the theory of cake or gel filtration and the Modified Fouling Index (MFI). Research was conducted using artificial colloidal solutions and a pilot plant equipped with ultrafiltration membranes. Polystyrene latex spheres, having a size of about 0.05-0.08 ÎĽm were used as a foulant.\ud \ud The result of this research was, that the measured and calculated values of flux decline of the ultrafiltration membranes as a function of time agree reasonably well. The difference between the measured and calculated values may be explained by the assumption, that initially blocking filtration occurs instead of cake or gel filtratio

    Probable pain on the pain assessment in impaired cognition (PAIC15) instrument: assessing sensitivity and specificity of cut-offs against three standards

    Get PDF
    Observational pain scales can help to identify pain in persons with dementia who may have difficulty expressing pain verbally. The Pain Assessment in Impaired Cognition-15 (PAIC15) covers 15 items that indicate pain, but it is unclear how probable pain is, for each summed score (range 0-45). We aimed to determine sensitivity and specificity of cut-offs for probable pain on the PAIC15 against three standards: (1) self-report when able, (2) the established Pain Assessment in Advanced Dementia (PAINAD) cut-off of 2, and (3) observer's overall estimate based on a series of systematic observations. We used data of 238 nursing home residents with dementia who were observed by their physician in training or nursing staff in the context of an evidence-based medicine (EBM) training study, with re-assessment after 2 months in 137 residents. The area under the ROC curve was excellent against the PAINAD cut-off (>= 0.8) but acceptable or less than acceptable for the other two standards. Across standards and criteria for optimal sensitivity and specificity, PAIC15 scores of 3 and higher represent possible pain for screening in practice, with sensitivity and specificity against self-report in the 0.5 to 0.7 range. While sensitivity for screening in practice may be too low, a cut-off of 4 is reasonable to indicate probable pain in research.Geriatrics in primary carePublic Health and primary car

    The Ethic of Responsibility: Max Weber’s Verstehen and Shared Decision-Making in Patient-Centred Care

    No full text

    The Impossible Clinic: A Critical Sociology of Evidence-Based Medicine

    No full text

    Getting Real about Nominalism Again

    No full text

    26Al beam production by a solid state laser ion source at TRIUMF

    No full text
    Many experiments carried out at radioactive beam facilities require the production of intense, isotopically clean and isobar free beams of a particular isotope. At TRIUMF the addition of a resonant ionization laser ion source (TRILIS) enables a multitude of new beams and therefore new experiments to be carried out. 26Al was one of the first radioactive ion beams delivered to an experiment using TRILIS. This paper outlines the development of the 26Al ion beam for nuclear astrophysics
    corecore