3,466 research outputs found
A Chinese Chan-Based Mind-Body Intervention Improves Sleep on Patients with Depression: A Randomized Controlled Trial
Sleep disturbance is a common problem associated with depression, and cognitive-behavioral therapy (CBT) is a more common behavioral intervention for sleep problems. The present study compares the effect of a newly developed Chinese Chan-based intervention, namely Dejian mind-body intervention (DMBI), with the CBT on improving sleep problems of patients with depression. Seventy-five participants diagnosed with major depressive disorder were randomly assigned to receive 10 weekly sessions of CBT or DMBI, or placed on a waitlist. Measurements included ratings by psychiatrists who were blinded to the experimental design, and a standardized questionnaire on sleep quantity and quality was obtained before and after the 10-week intervention. Results indicated that both the CBT and DMBI groups demonstrated significantly reduced sleep onset latency and wake time after sleep onset (effect size range = 0.46–1.0, P ≤ 0.05) as compared to nonsignificant changes in the waitlist group (P > 0.1). Furthermore, the DMBI group, but not the CBT or waitlist groups, demonstrated significantly reduced psychiatrist ratings on overall sleep problems (effect size = 1.0, P = 0.00) and improved total sleep time (effect size = 0.8, P = 0.05) after treatment. The present findings suggest that a Chinese Chan-based mind-body intervention has positive effects on improving sleep in individuals with depression
Recommended from our members
Relationship between diffusion capacity and small airway abnormality in COPDGene.
Impaired single breath carbon monoxide diffusing capacity (DLCO) is associated with emphysema. Small airways disease (SAD) may be a precursor lesion to emphysema, but the relationship between SAD and DLCO is undescribed. We hypothesized that in mild COPD, functional SAD (fSAD) defined by computed tomography (CT) and Parametric Response Mapping methodology would correlate with impaired DLCO. Using data from ever-smokers in the COPDGene cohort, we established that fSAD correlated significantly with lower DLCO among both non-obstructed and GOLD 1-2 subjects. The relationship between DLCO with CT-defined emphysema was present in all GOLD stages, but most prominent in severe disease. TRIAL REGISTRATION: NCT00608764. Registry: COPDGene. Registered 06 February 2008, retrospectively registered
Pair production of charged Higgs bosons in the Left-Right Twin Higgs model at the ILC and LHC
Left-Right twin Higgs(LRTH) model predicts the existence of a pair of charged
Higgs . In this paper, we study the production of the charged Higgs
bosons pair via the process at
the International Linear Collider(ILC). The numerical results show that the
production rates are at the level of several tens fb, this process can produce
the adequate distinct multi-jet final states and the SM background can be
efficiently reduced. We also discuss the charged Higgs boson pair production
via the process at the Large Hadron
Collider(LHC) and estimate there production rates. We find that, as long as the
charged Higgs bosons are not too heavy, they can be abundantly produced at the
LHC. The possible signatures of these new particles might be detected at the
ILC and LHC experiments.Comment: 15 pages, 5 figures, discussion extended, reference added, typos
fixed, revised version to be published in Eur.Phys.J.
Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
We report the results of a search for neutrinoless double-beta decay in a
9.8~kgyr exposure of Te using a bolometric detector array,
CUORE-0. The characteristic detector energy resolution and background level in
the region of interest are FWHM and ~counts/(keVkgyr), respectively. The
median 90%~C.L. lower-limit sensitivity of the experiment is and surpasses the sensitivity of previous searches. We find
no evidence for neutrinoless double-beta decay of Te and place a
Bayesian lower bound on the decay half-life, ~ at 90%~C.L. Combining CUORE-0 data with the 19.75~kgyr
exposure of Te from the Cuoricino experiment we obtain at 90%~C.L.~(Bayesian), the most stringent
limit to date on this half-life. Using a range of nuclear matrix element
estimates we interpret this as a limit on the effective Majorana neutrino mass,
-- .Comment: 6 pages, 5 figures, updated version as published in PR
CeLAND: search for a 4th light neutrino state with a 3 PBq 144Ce-144Pr electron antineutrino generator in KamLAND
The reactor neutrino and gallium anomalies can be tested with a 3-4 PBq
(75-100 kCi scale) 144Ce-144Pr antineutrino beta-source deployed at the center
or next to a large low-background liquid scintillator detector. The
antineutrino generator will be produced by the Russian reprocessing plant PA
Mayak as early as 2014, transported to Japan, and deployed in the Kamioka
Liquid Scintillator Anti-Neutrino Detector (KamLAND) as early as 2015.
KamLAND's 13 m diameter target volume provides a suitable environment to
measure the energy and position dependence of the detected neutrino flux. A
characteristic oscillation pattern would be visible for a baseline of about 10
m or less, providing a very clean signal of neutrino disappearance into a
yet-unknown, sterile neutrino state. This will provide a comprehensive test of
the electron dissaperance neutrino anomalies and could lead to the discovery of
a 4th neutrino state for Delta_m^2 > 0.1 eV^2 and sin^2(2theta) > 0.05.Comment: 67 pages, 50 figures. Th. Lasserre thanks the European Research
Council for support under the Starting Grant StG-30718
CUORE-0 results and prospects for the CUORE experiment
With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV
(0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory
for Rare Events) experiment aims at searching for neutrinoless double beta
decay of 130Te with unprecedented sensitivity. Expected to start data taking in
2015, CUORE is currently in an advanced construction phase at LNGS. CUORE
projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1
sigma (9.5E25 y at the 90% confidence level), in five years of live time,
corresponding to an upper limit on the effective Majorana mass in the range
40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric
detectors could improve CUORE sensitivity and competitiveness of bolometric
detectors towards a full analysis of the inverted neutrino mass hierarchy.
CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE
experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g
each, arranged in a 13 floor structure) constructed strictly following CUORE
recipes both for materials and assembly procedures. An experiment its own,
CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta
decay half-life of 130Te around 3E24 y in one year of live time. We present an
update of the data, corresponding to an exposure of 18.1 kg y. An analysis of
the background indicates that the CUORE performance goal is satisfied while the
sensitivity goal is within reach.Comment: 10 pages, 3 figures, to appear in the proceedings of NEUTRINO 2014,
26th International Conference on Neutrino Physics and Astrophysics, 2-7 June
2014, held at Boston, Massachusetts, US
Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in Te with CUORE-0
We describe in detail the methods used to obtain the lower bound on the
lifetime of neutrinoless double-beta () decay in Te and
the associated limit on the effective Majorana mass of the neutrino using the
CUORE-0 detector. CUORE-0 is a bolometric detector array located at the
Laboratori Nazionali del Gran Sasso that was designed to validate the
background reduction techniques developed for CUORE, a next-generation
experiment scheduled to come online in 2016. CUORE-0 is also a competitive
decay search in its own right and functions as a platform to
further develop the analysis tools and procedures to be used in CUORE. These
include data collection, event selection and processing, as well as an
evaluation of signal efficiency. In particular, we describe the amplitude
evaluation, thermal gain stabilization, energy calibration methods, and the
analysis event selection used to create our final decay search
spectrum. We define our high level analysis procedures, with emphasis on the
new insights gained and challenges encountered. We outline in detail our
fitting methods near the hypothesized decay peak and catalog
the main sources of systematic uncertainty. Finally, we derive the
decay half-life limits previously reported for CUORE-0,
yr, and in combination with the Cuoricino
limit, yr.Comment: 18 pages, 18 figures. (Version 3 reflects only minor changes to the
text. Few additional details, no major content changes.
Measurement of the Two-Neutrino Double Beta Decay Half-life of Te with the CUORE-0 Experiment
We report on the measurement of the two-neutrino double beta decay half-life
of Te with the CUORE-0 detector. From an exposure of 33.4 kgy of
TeO, the half-life is determined to be = [8.2 0.2
(stat.) 0.6 (syst.)] 10y. This result is obtained after a
detailed reconstruction of the sources responsible for the CUORE-0 counting
rate, with a specific study of those contributing to the Te
neutrinoless double beta decay region of interest.Comment: Corrected typo in section 9: 3.43E5 Bq/kg should have read 3.43E-5
Bq/k
Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments
CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless
double beta decay of 130Te. The detector is being constructed at the Laboratori
Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If
the target background of 0.01 counts/keV/kg/y will be reached, in five years of
data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0
is a smaller experiment constructed to test and demonstrate the performances
expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers
that started taking data in spring 2013. The status and perspectives of CUORE
will be discussed, and the first CUORE-0 data will be presented.Comment: 7 pages, 4 figures, to be published in the proceedings of ICHEP 2014,
37th International Conference on High Energy Physics, Valencia (Spain) 2-9
July 201
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will
search for neutrinoless double beta decay of Te. With 741 kg of TeO
crystals and an excellent energy resolution of 5 keV (0.2%) at the region of
interest, CUORE will be one of the most competitive neutrinoless double beta
decay experiments on the horizon. With five years of live time, CUORE projected
neutrinoless double beta decay half-life sensitivity is y
at ( y at the 90% confidence level), which
corresponds to an upper limit on the effective Majorana mass in the range
40--100 meV (50--130 meV). Further background rejection with auxiliary light
detector can significantly improve the search sensitivity and competitiveness
of bolometric detectors to fully explore the inverted neutrino mass hierarchy
with Te and possibly other double beta decay candidate nuclei.Comment: Submitted to the Proceedings of TAUP 2013 Conferenc
- …