274 research outputs found

    Generation of tunable subpicosecond light pulses in the midinfrared between 4.5 and 11.5 Mum

    Get PDF
    Stable subpicosecond infrared pulses in the spectral region of 4.5-11.5 ,um are generated by difference-frequency mixing in AgGaS2. The system uses femtosecond pulses from a Ti:sapphire regenerative amplifier and from a tunable traveling-wave dye laser. The infrared pulses have a duration of 400 fs, an energy of more than 10 nJ, and a repetition rate of 1 kHz

    From Data to Discourse: How Communicating Civic Data Can Provide a Participatory Structure for Sustainable Cities and Communities

    Get PDF
    This study explores how Civil Society Organizations (CSOs) have leveraged civic data to facilitate democratic participatory structure for sustainability transitions around the case of bicycle counters in three US cities over a ten-year period (Seattle, San Francisco, Portland). We identified that CSOs have played crucial roles in public discourse by (1) sustaining long-term public issues through shaping affective as well as analytical discourses and (2) fostering citizens’ sense of ownership and contributions toward sensor devices and the data they generate by contextualizing them through local civic life as well as connecting issues to actors in other cities

    Femtosecond spectroscopy of the primary electron transfer in photosynthetic reaction centers

    Get PDF

    A new modification of the chiron ACS assay for total prostate-specific antigen achieves equimolar response characteristics and improves the detection of prostate cancer

    Get PDF
    Nonequimolar-response assays for prostate-specific antigen (PSA) are criticized for overestimating total PSA in some men without prostate cancer (PCA), and underestimating total PSA in some men with PCA. We recently studied three nonequimolar-response PSA assays that had undergone modifications. While two of the studied assays achieved equimolar-response characteristics with improved areas under receiver operating characteristic (ROC) curves (AUC), the modification of the Chiron ACS PSA assay (ACS PSA2, Chiron) failed to achieve this. Recently, the ACS assay underwent another modification (ACS PSA, Bayer), which we investigated. Sera from 305 men (155 without and 150 with PCA, PSA greater than or equal to2 and less than or equal to30 mug/l, TandemE) were measured using both modifications of the ACS assay and equimolar-response reference methods (TandemR free and Tandem E, Hybritech). Molar response relative to the reference method and clinical performance (comparison of AUCs) between the previous and new ACS assay modifications were studied. The new modification of the ACS assay (ACS PSA, Bayer) achieved equimolar-response characteristics but reported lower values (average 10%) than the Tandem E assay. Compared to the previous modification (ACS PSA2, Chiron), a 3% improvement in AUC (p=0.01) was found. Using results of the redesigned equimolar-response assay (ACS PSA, Bayer), we calculated that 6 of 155 men without PCA in this sample set could be spared unnecessary biopsy compared with the previous nonequimolar-response assay (ACS PSA2, Chiron) without missing additional PCA (90% sensitivity). These data provide additional evidence for clinical advantages of equimolar-response over nonequimolar-response PSA assay formats

    Exploring Patterns of Dynamic Size Changes of Lesions after Hepatic Microwave Ablation in an In Vivo Porcine Model

    Get PDF
    Microwave ablation (MWA) is a type of minimally invasive cancer therapy that uses heat to induce necrosis in solid tumours. Inter- and post-ablational size changes can influence the accuracy of control imaging, posing a risk of incomplete ablation. The present study aims to explore post-ablation 3D size dynamics in vivo using computed tomography (CT). Ten MWA datasets obtained in nine healthy pigs were used. Lesions were subdivided along the z-axis with an additional planar subdivision into eight subsections. The volume of the subsections was analysed over different time points, subsequently colour-coded and three-dimensionally visualized. A locally weighted polynomial regression model (LOESS) was applied to describe overall size changes, and Student's t-tests were used to assess statistical significance of size changes. The 3D analysis showed heterogeneous volume changes with multiple small changes at the lesion margins over all time points. The changes were pronounced at the upper and lower lesion edges and characterized by initially eccentric, opposite swelling, followed by shrinkage. In the middle parts of the lesion, we observed less dimensional variations over the different time points. LOESS revealed a hyperbolic pattern for the volumetric changes with an initially significant volume increase of 11.6% (111.6% of the original volume) over the first 32 minutes, followed by a continuous decrease to 96% of the original volume (p < 0.05)

    Improved Visualization of the Necrotic Zone after Microwave Ablation Using Computed Tomography Volume Perfusion in an In Vivo Porcine Model

    Get PDF
    After hepatic microwave ablation, the differentiation between fully necrotic and persistent vital tissue through contrast enhanced CT remains a clinical challenge. Therefore, there is a need to evaluate new imaging modalities, such as CT perfusion (CTP) to improve the visualization of coagulation necrosis. MWA and CTP were prospectively performed in five healthy pigs. After the procedure, the pigs were euthanized, and the livers explanted. Orthogonal histological slices of the ablations were stained with a vital stain, digitalized and the necrotic core was segmented. CTP maps were calculated using a dual-input deconvolution algorithm. The segmented necrotic zones were overlaid on the DICOM images to calculate the accuracy of depiction by CECT/CTP compared to the histological reference standard. A receiver operating characteristic analysis was performed to determine the agreement/true positive rate and disagreement/false discovery rate between CECT/CTP and histology. Standard CECT showed a true positive rate of 81% and a false discovery rate of 52% for display of the coagulation necrosis. Using CTP, delineation of the coagulation necrosis could be improved significantly through the display of hepatic blood volume and hepatic arterial blood flow (p < 0.001). The ratios of true positive rate/false discovery rate were 89%/25% and 90%/50% respectively. Other parameter maps showed an inferior performance compared to CECT

    High-sensitivity cardiac troponin T and copeptin assays to improve diagnostic accuracy of exercise stress test in patients with suspected coronary artery disease

    Get PDF
    Background: The average diagnostic sensitivity of exercise stress tests (ESTs) is lower than that of other non-invasive cardiac stress tests. The aim of the study was to examine whether high-sensitivity cardiac troponin T (hs-cTnT) or copeptin concentrations rise in response to inducible myocardial ischaemia and may improve the diagnostic accuracy of ESTs. Methods and results: An EST was performed stepwise on a bicycle ergometer by 383 consecutive patients with suspected or progression of coronary artery disease (CAD). In addition venous blood samples for measurement of hs-cTnT and copeptin were collected prior to EST, at peak exercise, and 4 h after EST. Coronary angiography was assessed for all patients. Patients with significant CAD (n=224) were more likely to be male and older compared to patients with non-significant CAD (n=169). Positive EST was documented in 125 (55.8%) patients with significant CAD and in 69 (43.4%) patients with non-significant CAD. Copeptin and hs-cTnT concentrations at baseline were higher in patients with significant CAD (copeptin: 10.8 pmol/l (interquartile range (IQR) 8.1–15.6) vs 9.4 pmol/l (IQR 7.1–13.9); p=0.04; hs-cTnT: 3.0 ng/l (IQR <3.0–5.4) vs <3.0 ng/l (IQR <3.0); p=0.006). Hs-cTnT improved sensitivity (61.6% vs 55.8%), specificity (67.7% vs 56.6%) and the positive predictive value (PPV) (72.3% vs 64.4%) and negative (55.2% vs 47.6%) predictive value (NPV) of EST. Copeptin could not improve sensitivity (55.4% vs 55.8%) and reduced specificity, PPV and NPV. Conclusions: The measurement of hs-cTnT during EST improves sensitivity, specificity, and positive and negative predictive values. In contrast, measurement of copeptin does not improve diagnostic sensitivity and reduces specificity
    • …
    corecore