1,297 research outputs found

    A cross sectional study of water quality from dental unit water lines in dental practices in the West of Scotland

    Get PDF
    OBJECTIVE: To determine the microbiological quality of water from dental units in a general practice setting and current practice for disinfection of units. DESIGN: A cross-sectional study of the water quality from 40 dental units in 39 general practices and a questionnaire of the disinfection protocols used in those practices. SETTING: NHS practices in primarydental care. SUBJECTS: Thirty-nine general practices from the West of Scotland. METHODS: Water samples were collected on two separate occasions from dental units and analysed for microbiological quality by the total viable count (TVC) method. Water specimens were collected from the triple syringe, high speed outlet, cup filler and surgery tap. Each participating practitioner was asked to complete a questionnaire. Results Microbial contamination was highest from the high speed outlet followed by the triple syringe and cup filler. On average, the TVC counts from the high speed water lines at 37 degrees C and for the high speed lines, triple syringe and cup filler at 22 degrees C were significantly higher than that from the control tap water specimens. The study included units from 11 different manufacturers with ages ranging from under one year to over eight years. The age of the dental unit analysed did not appear to influence the level of microbial contamination. Five of the practices surveyed used disinfectants to clean the dental units but these had no significant effect on the microbiological quality of the water. The majority of dental units (25 out of 40) were never flushed with water between patients. A number of different non-sterile irrigants were used for surgical procedures. CONCLUSION: The microbiological quality of water from dental units in general dental practice is poor compared with that from drinking water sources. Suitable sterile irrigants should be used for surgical procedures in dental practice. Further work is required for pragmatic decontamination regimens of dental unit water lines in a general dental practice setting

    Evaluation of the efficacy of Alpron disinfectant for dental unit water lines

    Get PDF
    AIMS: To assess the efficacy of a disinfectant, Alpron, for controlling microbial contamination within dental unit water lines. METHODS: The microbiological quality of water emerging from the triple syringe, high speed handpiece, cup filler and surgery hand wash basin from six dental units was assessed for microbiological total viable counts at 22 degrees C and 37 degrees C before and after treatment with Alpron solutions. RESULTS: The study found that the use of Alpron disinfectant solutions could reduce microbial counts in dental unit water lines to similar levels for drinking water. This effect was maintained in all units for up to six weeks following one course of treatment. In four out of six units the low microbial counts were maintained for 13 weeks. CONCLUSIONS: Disinfectants may have a short term role to play in controlling microbial contamination of dental unit water lines to drinking water quality. However, in the longer term attention must be paid to redesigning dental units to discourage the build up of microbial biofilms

    kHz Quasi-Periodic Oscillations in the low-mass X-ray binary 4U 0614+09

    Full text link
    We report on a comprehensive analysis of the kilohertz (above 300 Hz) quasi-periodic oscillations (kHz QPOs) detected from the neutron star low-mass X-ray binary 4U0614+09 with the Rossi X-ray Timing Explorer (RXTE). With a much larger data set than previously analyzed (all archival data from February 1996 up to October 2007), we first investigate the reality of the 1330 Hz QPO reported by van Straaten et al. (2000). This QPO would be of particular interest since it has the highest frequency reported for any source. A thorough analysis of the same observation fails to confirm the detection. On the other hand, over our extended data set, the highest QPO frequency we measure for the upper kHz QPO is at about 1224 Hz; a value which is fully consistent with the maximum values observed in similar systems. Second, we demonstrate that the frequency dependence of the quality factor and amplitude of the lower and upper kHz QPOs follow the systematic trends seen in similar systems (Barret et al., 2006). In particular, 4U0614+09 shows a drop of the quality factor of the lower kHz QPO above 700 Hz. If this is due to an approach to the innermost stable circular orbit, it implies a neutron star mass of about 1.9 solar masses. Finally, when analyzing the data over fixed durations, we have found a gap in the frequency distribution of the upper QPO, associated with a local minimum of its amplitude. A similar gap is not present in the distribution of the lower QPO frequencies, suggesting some cautions when interpreting frequency ratio distributions, based on the occurrence of the lower QPO only.Comment: 10 pages, 6 color figures, 2 tables, Accepted for publication in MNRA

    Temporal and Individual Variation in Offspring Provisioning by Tree Swallows: A New Method of Automated Nest Attendance Monitoring

    Get PDF
    Studies of the ecology and evolution of avian nesting behavior have been limited by the difficulty and expense of sampling nest attendance behavior across entire days or throughout a substantial portion of the nestling period. Direct observation of nesting birds using human observers and most automated devices requires sub-sampling of the nestling period, which does not allow for the quantification of the duration of chick-feeding by parents within a day, and may also inadequately capture temporal variation in the rate at which chicks are fed. Here I describe an inexpensive device, the Automated Perch Recorder (APR) system, which collects accurate, long-term data on hourly rates of nest visitation, the duration of a pair's workday, and the total number of visits the pair makes to their nest across the entire period for which it is deployed. I also describe methods for verifying the accuracy of the system in the field, and several examples of how these data can be used to explore the causes of variation in and tradeoffs between the rate at which birds feed their chicks and the total length of time birds spend feeding chicks in a day

    Dual-gated bilayer graphene hot electron bolometer

    Full text link
    Detection of infrared light is central to diverse applications in security, medicine, astronomy, materials science, and biology. Often different materials and detection mechanisms are employed to optimize performance in different spectral ranges. Graphene is a unique material with strong, nearly frequency-independent light-matter interaction from far infrared to ultraviolet, with potential for broadband photonics applications. Moreover, graphene's small electron-phonon coupling suggests that hot-electron effects may be exploited at relatively high temperatures for fast and highly sensitive detectors in which light energy heats only the small-specific-heat electronic system. Here we demonstrate such a hot-electron bolometer using bilayer graphene that is dual-gated to create a tunable bandgap and electron-temperature-dependent conductivity. The measured large electron-phonon heat resistance is in good agreement with theoretical estimates in magnitude and temperature dependence, and enables our graphene bolometer operating at a temperature of 5 K to have a low noise equivalent power (33 fW/Hz1/2). We employ a pump-probe technique to directly measure the intrinsic speed of our device, >1 GHz at 10 K.Comment: 5 figure

    Risk assessment for the spread of Serratia marcescens within dental-unit waterline systems using Vermamoeba vermiformis

    Get PDF
    Vermamoeba vermiformis is associated with the biofilm ecology of dental-unit waterlines (DUWLs). This study investigated whether V. vermiformis is able to act as a vector for potentially pathogenic bacteria and so aid their dispersal within DUWL systems. Clinical dental water was initially examined for Legionella species by inoculating it onto Legionella selective-medium plates. The molecular identity/profile of the glassy colonies obtained indicated none of these isolates were Legionella species. During this work bacterial colonies were identified as a non-pigmented Serratia marcescens. As the water was from a clinical DUWL which had been treated with Alpronâ„¢ this prompted the question as to whether S. marcescens had developed resistance to the biocide. Exposure to Alpronâ„¢ indicated that this dental biocide was effective, under laboratory conditions, against S. marcescens at up to 1x108 colony forming units/millilitre (cfu/ml). V. vermiformis was cultured for eight weeks on cells of S. marcescens and Escherichia coli. Subsequent electron microscopy showed that V. vermiformis grew equally well on S. marcescens and E. coli (p = 0.0001). Failure to detect the presence of S. marcescens within the encysted amoebae suggests that V. vermiformis is unlikely to act as a vector supporting the growth of this newly isolated, nosocomial bacterium

    The Functional DRD3 Ser9Gly Polymorphism (rs6280) Is Pleiotropic, Affecting Reward as Well as Movement

    Get PDF
    Abnormalities of motivation and behavior in the context of reward are a fundamental component of addiction and mood disorders. Here we test the effect of a functional missense mutation in the dopamine 3 receptor (DRD3) gene (ser9gly, rs6280) on reward-associated dopamine (DA) release in the striatum. Twenty-six healthy controls (HCs) and 10 unmedicated subjects with major depressive disorder (MDD) completed two positron emission tomography (PET) scans with [11C]raclopride using the bolus plus constant infusion method. On one occasion subjects completed a sensorimotor task (control condition) and on another occasion subjects completed a gambling task (reward condition). A linear regression analysis controlling for age, sex, diagnosis, and self-reported anhedonia indicated that during receipt of unpredictable monetary reward the glycine allele was associated with a greater reduction in D2/3 receptor binding (i.e., increased reward-related DA release) in the middle (anterior) caudate (p<0.01) and the ventral striatum (p<0.05). The possible functional effect of the ser9gly polymorphism on DA release is consistent with previous work demonstrating that the glycine allele yields D3 autoreceptors that have a higher affinity for DA and display more robust intracellular signaling. Preclinical evidence indicates that chronic stress and aversive stimulation induce activation of the DA system, raising the possibility that the glycine allele, by virtue of its facilitatory effect on striatal DA release, increases susceptibility to hyperdopaminergic responses that have previously been associated with stress, addiction, and psychosis
    • …
    corecore