9,837 research outputs found
Phonological Units in Spoken Word Production: Insights from Cantonese
published_or_final_versio
Progenitor-like cells derived from mouse kidney protect against renal fibrosis in a remnant kidney model via decreased endothelial mesenchymal transition
Showing A quantification of GFP-positive cells in the lung after intravenous injection of MKPCs in five-sixths nephrectomized mice (y axis shows the number of cells, while the x axis (FL1-H) shows the fluorescence intensity; M1 is the area of GFP-positive cells) and B immunohistochemistry of the lung after intravenous injection of MKPCs into a mouse that underwent five-sixths nephrectomy. Few GFP positive cells were found in the lung at the first day but there were no GFP-positive cells at week 14. (TIFF 2253 kb
Sample entropy analysis of EEG signals via artificial neural networks to model patients' consciousness level based on anesthesiologists experience.
Electroencephalogram (EEG) signals, as it can express the human brain's activities and reflect awareness, have been widely used in many research and medical equipment to build a noninvasive monitoring index to the depth of anesthesia (DOA). Bispectral (BIS) index monitor is one of the famous and important indicators for anesthesiologists primarily using EEG signals when assessing the DOA. In this study, an attempt is made to build a new indicator using EEG signals to provide a more valuable reference to the DOA for clinical researchers. The EEG signals are collected from patients under anesthetic surgery which are filtered using multivariate empirical mode decomposition (MEMD) method and analyzed using sample entropy (SampEn) analysis. The calculated signals from SampEn are utilized to train an artificial neural network (ANN) model through using expert assessment of consciousness level (EACL) which is assessed by experienced anesthesiologists as the target to train, validate, and test the ANN. The results that are achieved using the proposed system are compared to BIS index. The proposed system results show that it is not only having similar characteristic to BIS index but also more close to experienced anesthesiologists which illustrates the consciousness level and reflects the DOA successfully.This research is supported by the Center forDynamical Biomarkers and Translational Medicine, National Central University, Taiwan, which is sponsored by Ministry of Science and Technology (Grant no. MOST103-2911-I-008-001). Also, it is supported by National Chung-Shan Institute of Science & Technology in Taiwan (Grant nos. CSIST-095-V301 and CSIST-095-V302)
Visual Similarity Perception of Directed Acyclic Graphs: A Study on Influencing Factors
While visual comparison of directed acyclic graphs (DAGs) is commonly
encountered in various disciplines (e.g., finance, biology), knowledge about
humans' perception of graph similarity is currently quite limited. By graph
similarity perception we mean how humans perceive commonalities and differences
in graphs and herewith come to a similarity judgment. As a step toward filling
this gap the study reported in this paper strives to identify factors which
influence the similarity perception of DAGs. In particular, we conducted a
card-sorting study employing a qualitative and quantitative analysis approach
to identify 1) groups of DAGs that are perceived as similar by the participants
and 2) the reasons behind their choice of groups. Our results suggest that
similarity is mainly influenced by the number of levels, the number of nodes on
a level, and the overall shape of the graph.Comment: Graph Drawing 2017 - arXiv Version; Keywords: Graphs, Perception,
  Similarity, Comparison, Visualizatio
Electromagnetic emissions from the IC packaging
The EMC and EMI of the IC packaging are becoming increasingly important to modern electronics. Its EMC, SI, and PI have been broadly attested. But electromagnetic radiations from IC packaging and the corresponding EMI were seldom studied. In this paper, the fundamental principles and properties of the electromagnetic radiations caused by vias and traces in IC packagings are carefully investigated. Various radiation mechanisms are analyzed for different representative scenarios. Numerical simulations are employed to support the analyzing results. © 2012 IEEE.published_or_final_versio
Electromagnetic emissions from the IC packaging
The EMC and EMI of the IC packaging are becoming increasingly important to modern electronics. Its EMC, SI, and PI have been broadly attested. But electromagnetic radiations from IC packaging and the corresponding EMI were seldom studied. In this paper, the fundamental principles and properties of the electromagnetic radiations caused by vias and traces in IC packagings are carefully investigated. Various radiation mechanisms are analyzed for different representative scenarios. Numerical simulations are employed to support the analyzing results. © 2012 IEEE.published_or_final_versio
Exploiting Polyhedral Symmetries in Social Choice
A large amount of literature in social choice theory deals with quantifying
the probability of certain election outcomes. One way of computing the
probability of a specific voting situation under the Impartial Anonymous
Culture assumption is via counting integral points in polyhedra. Here, Ehrhart
theory can help, but unfortunately the dimension and complexity of the involved
polyhedra grows rapidly with the number of candidates. However, if we exploit
available polyhedral symmetries, some computations become possible that
previously were infeasible. We show this in three well known examples:
Condorcet's paradox, Condorcet efficiency of plurality voting and in Plurality
voting vs Plurality Runoff.Comment: 14 pages; with minor improvements; to be published in Social Choice
  and Welfar
A potential risk of overestimating apparent diffusion coefficient in parotid glands
Objectives: To investigate transient signal loss on diffusion weighted images (DWI) and overestimation of apparent diffusion coefficient (ADC) in parotid glands using single shot echoplanar DWI (EPDWI). Materials and Methods: This study enrolled 6 healthy subjects and 7 patients receiving radiotherapy. All participants received dynamic EPDWI with a total of 8 repetitions. Imaging quality of DWI was evaluated. Probability of severe overestimation of ADC (soADC), defined by an ADC ratio more than 1.2, was calculated. Error on T2WI, DWI, and ADC was computed. Statistical analysis included paired Student t testing and Mann-Whitney U test. A P value less than 0.05 was considered statistically significant. Results: Transient signal loss was visually detected on some excitations of DWI but not on T2WI or mean DWI. soADC occurred randomly among 8 excitations and 3 directions of diffusion encoding gradients. Probability of soADC was significantly higher in radiotherapy group (42.86%) than in healthy group (24.39%). The mean error percentage decreased as the number of excitations increased on all images, and, it was smallest on T2WI, followed by DWI and ADC in an increasing order. Conclusions: Transient signal loss on DWI was successfully detected by dynamic EPDWI. The signal loss on DWI and overestimation of ADC could be partially remedied by increasing the number of excitations. © 2015 Liu et al.published_or_final_versio
High Fidelity Tape Transfer Printing Based On Chemically Induced Adhesive Strength Modulation
Transfer printing, a two-step process (i.e. picking up and printing) for heterogeneous integration, has been widely exploited for the fabrication of functional electronics system. To ensure a reliable process, strong adhesion for picking up and weak or no adhesion for printing are required. However, it is challenging to meet the requirements of switchable stamp adhesion. Here we introduce a simple, high fidelity process, namely tape transfer printing(TTP), enabled by chemically induced dramatic modulation in tape adhesive strength. We describe the working mechanism of the adhesion modulation that governs this process and demonstrate the method by high fidelity tape transfer printing several types of materials and devices, including Si pellets arrays, photodetector arrays, and electromyography (EMG) sensors, from their preparation substrates to various alien substrates. High fidelity tape transfer printing of components onto curvilinear surfaces is also illustrated
- …
