986 research outputs found

    Pairing correlations beyond the mean field

    Full text link
    We discuss dynamical pairing correlations in the context of configuration mixing of projected self-consistent mean-field states, and the origin of a divergence that might appear when such calculations are done using an energy functional in the spirit of a naive generalized density functional theory.Comment: Proceedings of the XIII Nuclear Physics Workshop ``Maria and Pierre Curie'' on ``Pairing and beyond - 50 years of the BCS model'', held at Kazimierz Dolny, Poland, September 27 - October 1, 2006. Int. J. Mod. Phys. E, in prin

    Non-Markovian effect on the quantum discord

    Full text link
    We study the non-Markovian effect on the dynamics of the quantum discord by exactly solving a model consisting of two independent qubits subject to two zero-temperature non-Markovian reservoirs, respectively. Considering the two qubits initially prepared in Bell-like or extended Werner-like states, we show that there is no occurrence of the sudden death, but only instantaneous disappearance of the quantum discord at some time points, in comparison to the entanglement sudden death in the same range of the parameters of interest. It implies that the quantum discord is more useful than the entanglement to describe quantum correlation involved in quantum systems.Comment: 5 pages, 5 figure

    Spin correlations in the electron-doped high-transition-temperature superconductor Nd{2-x}Ce{x}CuO{4+/-delta}

    Full text link
    High-transition-temperature (high-Tc) superconductivity develops near antiferromagnetic phases, and it is possible that magnetic excitations contribute to the superconducting pairing mechanism. To assess the role of antiferromagnetism, it is essential to understand the doping and temperature dependence of the two-dimensional antiferromagnetic spin correlations. The phase diagram is asymmetric with respect to electron and hole doping, and for the comparatively less-studied electron-doped materials, the antiferromagnetic phase extends much further with doping [1, 2] and appears to overlap with the superconducting phase. The archetypical electron-doped compound Nd{2-x}Ce{x}CuO{4\pm\delta} (NCCO) shows bulk superconductivity above x \approx 0.13 [3, 4], while evidence for antiferromagnetic order has been found up to x \approx 0.17 [2, 5, 6]. Here we report inelastic magnetic neutron-scattering measurements that point to the distinct possibility that genuine long-range antiferromagnetism and superconductivity do not coexist. The data reveal a magnetic quantum critical point where superconductivity first appears, consistent with an exotic quantum phase transition between the two phases [7]. We also demonstrate that the pseudogap phenomenon in the electron-doped materials, which is associated with pronounced charge anomalies [8-11], arises from a build-up of spin correlations, in agreement with recent theoretical proposals [12, 13].Comment: 5 pages, 4 figure

    Fine structure of alpha decay in odd nuclei

    Get PDF
    Using an alpha decay level scheme, an explanation for the fine structure in odd nuclei is evidenced by taking into account the radial and rotational couplings between the unpaired nucleon and the core of the decaying system. It is stated that the experimental behavior of the alpha decay fine structure phenomenon is directed by the dynamical characteristics of the system.Comment: 8 pages, 3 figures, REVTex, submitted to Physical Review

    Contrast material–enhanced MRA overestimates severity of carotid stenosis, compared with 3D time-of-flight MRA

    Get PDF
    AbstractObjectiveNon–contrast-enhanced magnetic resonance angiography (MRA) carotid imaging with the time-of-flight (TOF) technique compares favorably with angiography, ultrasound, and excised plaques. However, gadolinium contrast-enhanced MRA (CE-MRA) has almost universally replaced TOF-MRA, because it reduces imaging time (25 seconds vs 10 minutes) and improves signal-to-noise ratio. In our practice we found alarming discrepancies between CE-MRA and TOF-MRA, which was the impetus for this study.Study designTo compare the two techniques, we measured stenosis, demonstrated on three-dimensional images obtained at TOF and CE-MRA, in 107 carotid arteries in 58 male patients. The measurements were made on a Cemax workstation equipped with enlargement and measurement tools. Measurements to 0.1 mm were made at 90 degrees to the flow channel at the area of maximal stenosis and distal to the bulb where the borders of the internal carotid artery lumen were judged to be parallel (North American Symptomatic Carotid Endarterectomy Trial criteria). Experiments with carotid phantoms were done to test the comtribution of imaging software to image quality.ResultsTwelve arteries were occluded. In the remaining 95 arteries, compared with TOF-MRA, CE-MRA demonstrated a greater degree of stenosis in 42 arteries, a lesser degree of stenosis in 14 arteries, and similar (±5%) stenosis in 39 arteries (P = .02, χ2 analysis). The largest discrepancies were arteries with 0% to 70% stenosis. In those arteries in which CE-MRA identified a greater degree of stenosis than shown with TOF-MRA, mean increase was 21% for 0% to 29% stenosis, 36% for 30% to 49% stenosis, and 38% for of 50% to 69% stenosis. The carotid phantom experiments showed that the imaging parameters of CE-MRA, particularly the plane on which frequency encoding gradients were applied, reduced signal acquisition at the area of stenosis.ConclusionsCollectively these data demonstrate that CE-MRA parameters must be retooled if the method is to be considered reliable for determination of severity of carotid artery stenosis. CE-MRA is an excellent screening technique, but only TOF-MRA should be used to determine degree of carotid artery stenosis

    Double-lumen carotid plaque: A morbid configuration

    Get PDF
    AbstractDuring analysis of carotid plaque anatomy for a multicenter carotid imaging trial, we examined plaque specimens from 5 patients with double internal carotid artery lumina. Four of the 5 patients had symptoms referable to the lesion. The second lumen was noted when the plaque specimens were examined ex vivo with high-resolution (200 ÎĽm3) magnetic resonance imaging. Plaque structure was correctly identified in only 1 patient preoperatively. However, during retrospective review of the preoperative imaging studies, the second internal carotid artery lumen was identified in 3 patients
    • …
    corecore