167 research outputs found

    Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    Get PDF
    Item does not contain fulltextOBJECTIVES: Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. METHODS: A Medtronic Hall tilting disc (MH), and Carbomedics (CM), St Jude (SJM), and ON-X bileaflet valves underwent CT in an in-vitro model using retrospective gating with a 64 detector CT system in stationary and pulsatile conditions. Artifacts and radiopaque component volumes were quantified with thresholds based on surrounding structures and valvular components. RESULTS: Hypodense artifacts volumes (mm(3)) were 1,029 +/- 147, 535 +/- 53, 371 +/- 16, and 366 +/- 18 for the SJM, MH, CM and ON-X valves (p < 0.001 except for the latter two valves p = 0.43). Hyperdense artifact volumes were 3,546 +/- 141, 2,387 +/- 103, 2,003 +/- 102, and 3,033 +/- 31 for the SJM, MH, CM and ON-X valve, respectively (all differences p < 0.001). Leaflet motion affected hypodense (F = 41.5, p < 0.001) and hyperdense artifacts (F = 53.7, p < 0.001). Closed and moving leaflets were associated with the least and the most artifacts respectively (p < 0.001, both artifact types). CONCLUSION: Both valve design and leaflet motion affect PHV-induced artifacts. Best imaging results may be expected for the CM valve during phases in which the leaflets are closed

    Dabigatran in patients with atrial fibrillation: perioperative and periinterventional management

    Get PDF
    In any type of invasive surgery, the patient’s individual risk of thromboembolism has to be weighed against the risk of bleeding. Based on various everyday situations in clinical routine, the purpose of the present expert recommendations is to provide appropriate perioperative and periinterventional management for patients with atrial fibrillation undergoing long-term treatment with the thrombin inhibitor dabigatran. As we currently have no routine laboratory test to measure therapeutic levels of the substance or the risk of bleeding, general measures such as a standardized documentation of the patient’s history, a sufficient time interval between the last preoperative dose and the procedure, and careful control of local hemostasis should be given special attention

    Covalent Attachment of Proteins to Solid Supports and Surfaces via Sortase-Mediated Ligation

    Get PDF
    BACKGROUND: There is growing interest in the attachment of proteins to solid supports for the development of supported catalysts, affinity matrices, and micro devices as well as for the development of planar and bead based protein arrays for multiplexed assays of protein concentration, interactions, and activity. A critical requirement for these applications is the generation of a stable linkage between the solid support and the immobilized, but still functional, protein. METHODOLOGY: Solid supports including crosslinked polymer beads, beaded agarose, and planar glass surfaces, were modified to present an oligoglycine motif to solution. A range of proteins were ligated to the various surfaces using the Sortase A enzyme of S. aureus. Reactions were carried out in aqueous buffer conditions at room temperature for times between one and twelve hours. CONCLUSIONS: The Sortase A transpeptidase of S. aureus provides a general, robust, and gentle approach to the selective covalent immobilization of proteins on three very different solid supports. The proteins remain functional and accessible to solution. Sortase mediated ligation is therefore a straightforward methodology for the preparation of solid supported enzymes and bead based assays, as well as the modification of planar surfaces for microanalytical devices and protein arrays

    Lipase-catalyzed Reactions at Interfaces of Two-phase Systems and Microemulsions

    Get PDF
    This work describes the influence of two polar lipids, Sn-1/3 and Sn-2 monopalmitin, on the activity of lipase in biphasic systems and in microemulsions. In previous communications, we have shown that Sn-2 monoglycerides can replace Sn-1,3 regiospecific lipases at the oil–water interface, causing a drastically reduced rate of lipolysis. We here demonstrate that even if the lipase is expelled from the interface, it can catalyze esterification of the Sn-2 monoglyceride with fatty acids in both macroscopic oil–water systems and in microemulsions, leading to formation of di- and triglycerides

    Measuring femoral lesions despite CT metal artefacts: a cadaveric study

    Get PDF
    Objective Computed tomography is the modality of choice for measuring osteolysis but suffers from metal-induced artefacts obscuring periprosthetic tissues. Previous papers on metal artefact reduction (MAR) show qualitative improvements, but their algorithms have not found acceptance for clinical applications. We investigated to what extent metal artefacts interfere with the segmentation of lesions adjacent to a metal femoral implant and whether metal artefact reduction improves the manual segmentation of such lesions. Materials and methods We manually created 27 periprosthetic lesions in 10 human cadaver femora. We filled the lesions with a fibrotic interface tissue substitute. Each femur was fitted with a polished tapered cobalt-chrome prosthesis and imaged twice—once with the metal, and once with a substitute resin prosthesis inserted. Metalaffected CTs were processed using standard back-projection as well as projection interpolation (PI) MAR. Two experienced users segmented all lesions and compared segmentation accuracy. Results We achieved accurate delineation of periprosthetic lesions in the metal-free images. The presence of a metal implant led us to underestimate lesion volume and introduced geometrical errors in segmentation boundaries.MediamaticsElectrical Engineering, Mathematics and Computer Scienc

    Backpack-mounted satellite transmitters do not affect reproductive performance in a migratory bustard

    Get PDF
    Backpack-mounted satellite transmitters (PTTs) are used extensively in the study of avian habitat use and of the movements and demography of medium- to large-bodied species, but can affect individuals’ performance and fitness. Transparent assessment of potential transmitter effects is important for both ethical accountability and confidence in, or adjustment to, life history parameter estimates. We assessed the influence of transmitters on seven reproductive parameters in Asian houbara Chlamydotis macqueenii, comparing 114 nests of 38 females carrying PTTs to 184 nests of untagged birds (non-PTT) over seven breeding seasons (2012‒2018) in Uzbekistan. There was no evidence of any influence of PTTs on: lay date (non-PTT x̅ = 91.7 Julian day ± 12.3 SD; PTT x̅ = 95.1 Julian day ± 15.7 SD); clutch size (non-PTT x̅ = 3.30 ± 0.68 SD; PTT x̅ = 3.25 ± 0.65 SD); mean egg weight at laying (non-PTT x̅ = 66.1g ± 5.4 SD; PTT x̅ = 66.4g ± 5.4 SD); nest success (non-PTT x̅ = 57.08% ± 4.3 SE; PTT x̅ = 58.24% ± 4.5 SE for nests started 2 April); egg hatchability (non-PTT x̅ = 88.3% ± 2.2 SE; PTT x̅ = 88.3% ± 2.6 SE); or chick survival to fledging from broods that had at least one surviving chick (non-PTT x̅ = 63.4% ± 4.2 SE; PTT x̅= 64.4% ± 4.7 SE). High nesting propensity (97.3% year-1 ± 1.9% SE) of tagged birds indicated minimal PTT effect on breeding probability. These findings show harness-mounted transmitters can give unbiased measures of demographic parameters of this species, and are relevant to other large-bodied, cursorial, ground-nesting birds of open habitats, particularly other bustards
    corecore