87 research outputs found

    Light mediated emergence of surface patterns in azopolymers at low temperatures

    Get PDF
    Polymer thin films doped with azobenzene molecules do have the ability to organize themselves in spontaneous surface relief gratings (SRG) under irradiation with a single polarized beam. To shed some light in this still unexplained phenomenon, we use a new method that permits us to access experimentally the very first steps of the pattern formation process. Decreasing the temperature, we slow down the formation and organization of patterns, due to the large increase of the viscosity and relaxation time of the azopolymer. As a result decreasing the temperature allows us to access and study much shorter time scales,in the physical mechanisms underlying the pattern formation, than previously reported. We find that the patterns organize themselves in sub-structures which size increase with the temperature, following the diffusion coefficient evolution of the material. That result suggests that the pattern formation and organization is mainly governed by diffusive processes, in agreement with some theories of the SRG formation. Decreasing further the temperature we observe the emergence of small voids located at the junction of the sub-structures.Comment: 6 figures, 13 pages

    Nonlinear Light Absorption in GaSe1-xSx Solid Solutions Under High Excitation Levels

    Get PDF

    Subwavelength atom localization via amplitude and phase control of the absorption spectrum

    Get PDF
    We propose a scheme for subwavelength localization of an atom conditioned upon the absorption of a weak probe field at a particular frequency. Manipulating atom-field interaction on a certain transition by applying drive fields on nearby coupled transitions leads to interesting effects in the absorption spectrum of the weak probe field. We exploit this fact and employ a four-level system with three driving fields and a weak probe field, where one of the drive fields is a standing-wave field of a cavity. We show that the position of an atom along this standing wave is determined when probe field absorption is measured. We find that absorption of the weak probe field at a certain frequency leads to subwavelength localization of the atom in either of the two half-wavelength regions of the cavity field by appropriate choice of the system parameters. We term this result as sub-half-wavelength localization to contrast it with the usual atom localization result of four peaks spread over one wavelength of the standing wave. We observe two localization peaks in either of the two half-wavelength regions along the cavity axis.Comment: Accepted for publication to Physical Review

    Theoretical study of dark resonances in micro-metric thin cells

    Full text link
    We investigate theoretically dark resonance spectroscopy for a dilute atomic vapor confined in a thin (micro-metric) cell. We identify the physical parameters characterizing the spectra and study their influence. We focus on a Hanle-type situation, with an optical irradiation under normal incidence and resonant with the atomic transition. The dark resonance spectrum is predicted to combine broad wings with a sharp maximum at line-center, that can be singled out when detecting a derivative of the dark resonance spectrum. This narrow signal derivative, shown to broaden only sub-linearly with the cell length, is a signature of the contribution of atoms slow enough to fly between the cell windows in a time as long as the characteristic ground state optical pumping time. We suggest that this dark resonance spectroscopy in micro-metric thin cells could be a suitable tool for probing the effective velocity distribution in the thin cell arising from the atomic desorption processes, and notably to identify the limiting factors affecting desorption under a grazing incidence.Comment: 12 pages, 11 figures theoretical articl

    Improving the power-delay performance in subthreshold source-coupled logic circuits

    Get PDF
    Subthreshold source-coupled logic (STSCL) circuits can be used in design of low-voltage and ultra-low power digital systems. This article introduces and analyzes new techniques for implementing complex digital systems using STSCL gates with an improved power-delay product (PDP) based on source-follower output stages. A test chip has been manufactured in a conventional digital 0.18μ\mum CMOS technology to evaluate the performance of the proposed STSCL circuit, and speed and PDP improvements by a factor of up to 2.4 were demonstrated

    Intravascular Ultrasound for Assessment of Residual Coarctation of the Aorta after Balloon Angioplasty in Infants

    Get PDF
    Intravascular ultrasound (IVUS) has been introduced as an accurate and minimally invasive diagnostic technique for the assessment of vascular anatomy and its abnormalities. We believe that IVUS can be used for clarifying the reasons for failure of balloon angiography in infantile coarctation of the aorta (CoA), because post-balloon angioplasty tearing, intimal flap, thrombosis and pseudoaneurysm of the aorta can be evaluated by IVUS with greater sensitivity and specificity. We aimed to assess the outcome of balloon angioplasty of CoA using angiography as the gold standard and IVUS as a new method in infants, comparing the two techniques for the evaluation of the diameter and area of CoA segment pre- and post-procedure. This cross-sectional study was performed on 18 infants hospitalized with a final diagnosis of CoA. All the infants underwent angiography and were also assessed by IVUS to measure the preoperative and postoperative diameter of the narrow segment in the two anterior�posterior and lateral views. In assessment by IVUS, the mean diameter of the coarctation site increased from 2.10 ± 0.30 mm to 4.50 ± 0.94 mm (P < 0.001). Similarly, the average minimum area of the coarctation level increased from 5.26 ± 1.50 mm2 to 13.77 ± 3.48 mm2 after angioplasty (P < 0.001). Comparing these findings, angiography and IVUS showed a high level of agreement. In the assessment of a dissection flap, there was a high level of agreement between angioplasty and IVUS before the procedure, but IVUS had higher accuracy after the procedure. Our study showed that IVUS was more reliable than angiography in the assessment of residual coarctation. IVUS yielded high sensitivity (58.3) and specificity (100) for discriminating the presence and absence of residual coarctation as well as the need for repeating the procedure. The assessment of coarctation before and after angioplasty procedures in children is possible using the IVUS method, with high accuracy. IVUS can offer greater accuracy than angiography in the evaluation of the coarctation area, detecting tears, dissection and flaps, and assessment of residual coarctation. © 2021, Springer Science+Business Media, LLC, part of Springer Nature

    Gain-assisted superluminal light propagation via incoherent pump field

    Full text link
    We investigate the dispersion and the absorption properties of a weak probe field in a three-level Lambda-type atomic system. We use just an incoherent field for controlling the group velocity of light. It is shown that the slope of dispersion changes from positive to negative just with changing the intensity of the indirect incoherent pumping field. Gain-assisted superluminal light propagation appears in this system. No laser field is used in the pumping processes
    corecore