32 research outputs found
Surface-electrode Rydberg-stark decelerator
Hydrogen atoms in Rydberg states with principal quantum numbers between 23 and 70 have been accelerated, decelerated, and electrostatically trapped using a surface-electrode Rydberg-Stark decelerator. By applying a set of oscillating electrical potentials to a two-dimensional array of electrodes on a printed circuit board (PCB), a continuously moving, three-dimensional electric trap with a predefined velocity and acceleration is generated. From an initial longitudinal velocity of 760m/s, final velocities of the Rydberg atoms ranging from 1200m/s to zero velocity in the laboratory-fixed frame of reference were achieved. Accelerated or decelerated atoms were detected directly by pulsed electric-field ionization. Atoms trapped at zero mean velocity above the PCB were reaccelerated off the PCB before field ionization. © 2012 American Physical Society
OCT Signs of Early Atrophy in Age-Related Macular Degeneration: Interreader Agreement: Classification of Atrophy Meetings Report 6.
PURPOSE: To determine the interreader agreement for incomplete retinal pigment epithelium (RPE) and outer retinal atrophy (iRORA) and complete RPE and outer retinal atrophy (cRORA) and their related features in age-related macular degeneration (AMD). DESIGN: Interreader agreement study. PARTICIPANTS: Twelve readers from 6 reading centers. METHODS: After formal training, readers qualitatively assessed 60 OCT B-scans from 60 eyes with AMD for 9 individual features associated with early atrophy and performed 7 different annotations to quantify the spatial extent of OCT features within regions of interest. The qualitative and quantitative features were used to derive the presence of iRORA and cRORA and also in an exploratory analysis to examine if agreement could be improved using different combinations of features to define OCT atrophy. MAIN OUTCOME MEASURES: Interreader agreement based on Gwet's first-order agreement coefficient (AC1) for qualitatively graded OCT features and classification of iRORA and cRORA, and smallest real difference (SRD) for quantitatively graded OCT features. RESULTS: Substantial or better interreader agreement was observed for all qualitatively graded OCT features associated with atrophy (AC1 = 0.63-0.87), except for RPE attenuation (AC1 = 0.46) and disruption (AC1 = 0.26). The lowest SRD for the quantitatively graded horizontal features was observed for the zone of choroidal hypertransmission (± 190.8 μm). Moderate agreement was found for a 3-category classification of no atrophy, iRORA, and cRORA (AC1 = 0.53). Exploratory analyses suggested a significantly higher level of agreement for a 3-category classification using (1) no atrophy; (2) presence of inner nuclear layer and outer plexiform layer subsidence, or a hyporeflective wedge-shaped band, as a less severe atrophic grade; and (3) the latter plus an additional requirement of choroidal hypertransmission of 250 μm or more for a more severe atrophic grade (AC1 = 0.68; P = 0.013). CONCLUSIONS: Assessment of iRORA and cRORA, and most of their associated features, can be performed relatively consistently and robustly. A refined combination of features to define early atrophy could further improve interreader agreement
Recommended from our members
Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report
Drusen are hallmarks of early and intermediate age-related macular degeneration (AMD) but their quantification remains a challenge. We compared automated drusen volume measurements between different OCT devices. We included 380 eyes from 200 individuals with bilateral intermediate (iAMD, n = 126), early (eAMD, n = 25) or no AMD (n = 49) from the MACUSTAR study. We assessed OCT scans from Cirrus (200 × 200 macular cube, 6 × 6 mm; Zeiss Meditec, CA) and Spectralis (20° × 20°, 25 B-scans; 30° × 25°, 241 B-scans; Heidelberg Engineering, Germany) devices. Sensitivity and specificity for drusen detection and differences between modalities were assessed with intra-class correlation coefficients (ICCs) and mean difference in a 5 mm diameter fovea-centered circle. Specificity was > 90% in the three modalities. In eAMD, we observed highest sensitivity in the denser Spectralis scan (68.1). The two different Spectralis modalities showed a significantly higher agreement in quantifying drusen volume in iAMD (ICC 0.993 [0.991-0.994]) than the dense Spectralis with Cirrus scan (ICC 0.807 [0.757-0.847]). Formulae for drusen volume conversion in iAMD between the two devices are provided. Automated drusen volume measures are not interchangeable between devices and softwares and need to be interpreted with the used imaging devices and software in mind. Accounting for systematic difference between methods increases comparability and conversion formulae are provided. Less dense scans did not affect drusen volume measurements in iAMD but decreased sensitivity for medium drusen in eAMD
Recommended from our members
Characteristics and Spatial Distribution of Structural Features in Age-Related Macular Degeneration: A MACUSTAR Study Report
PURPOSE: To report the prevalence and topographic distribution of structural characteristics in study participants with age-related macular degeneration (AMD) and controls in the cross-sectional study part of the MACUSTAR study (ClinicalTrials.gov Identifier: NCT03349801).
DESIGN: European, multicenter cohort study.
SUBJECTS: Overall, 301 eyes of 301 subjects with early (n = 34), intermediate (n = 168), and late AMD (n = 43), as well as eyes without any AMD features (n = 56).
METHODS: In study eyes with intermediate AMD (iAMD), the presence of structural AMD biomarkers, including pigmentary abnormalities (PAs), pigment epithelium detachment (PED), refractile deposits, reticular pseudodrusen (RPD), hyperreflective foci (HRF), incomplete/complete retinal pigment epithelium (RPE), and outer retinal atrophy (i/cRORA), and quiescent choroidal neovascularization (qCNV) was systematically determined in the prospectively acquired multimodal retinal imaging cross-sectional data set of MACUSTAR. Retinal layer thicknesses and the RPE drusen complex (RPEDC) volume were determined for the total study cohort in spectral-domain (SD) OCT imaging using a deep-learning-based algorithm.
MAIN OUTCOME MEASURES: Prevalence and topographic distribution of structural iAMD features.
RESULTS: A total of 301 study eyes of 301 subjects with a mean (± standard deviation) age of 71.2 ± 7.20 years (63.1% women) were included. Besides large drusen, the most prevalent structural feature in iAMD study eyes were PA (57.1%), followed by HRF (51.8%) and RPD (22.0%). Pigment epithelium detachment lesions were observed in 4.8%, vitelliform lesions in 4.2%, refractile deposits in 3.0%, and qCNV in 2.4%. Direct precursor lesions for manifest retinal atrophy were detected in 10.7% (iRORA) and 4.2% (cRORA) in iAMD eyes. Overall, the highest RPEDC volume with a median of 98.92 × 10-4 mm³ was found in iAMD study eyes. Spatial analysis demonstrated a predominant distribution of RPD in the superior and temporal subfields at a foveal eccentricity of 1.5 to 2 mm, whereas HRF and large drusen had a distinct topographic distribution involving the foveal center.
CONCLUSIONS: Detailed knowledge of the prevalence and distribution of structural iAMD biomarkers is vital to identify reliable outcome measure for disease progression. Longitudinal analyses are needed to evaluate their prognostic value for conversion to advanced disease stages.
FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references
Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report
Drusen are hallmarks of early and intermediate age-related macular degeneration (AMD) but their quantification remains a challenge. We compared automated drusen volume measurements between different OCT devices. We included 380 eyes from 200 individuals with bilateral intermediate (iAMD, n = 126), early (eAMD, n = 25) or no AMD (n = 49) from the MACUSTAR study. We assessed OCT scans from Cirrus (200 × 200 macular cube, 6 × 6 mm; Zeiss Meditec, CA) and Spectralis (20° × 20°, 25 B-scans; 30° × 25°, 241 B-scans; Heidelberg Engineering, Germany) devices. Sensitivity and specificity for drusen detection and differences between modalities were assessed with intra-class correlation coefficients (ICCs) and mean difference in a 5 mm diameter fovea-centered circle. Specificity was > 90% in the three modalities. In eAMD, we observed highest sensitivity in the denser Spectralis scan (68.1). The two different Spectralis modalities showed a significantly higher agreement in quantifying drusen volume in iAMD (ICC 0.993 [0.991–0.994]) than the dense Spectralis with Cirrus scan (ICC 0.807 [0.757–0.847]). Formulae for drusen volume conversion in iAMD between the two devices are provided. Automated drusen volume measures are not interchangeable between devices and softwares and need to be interpreted with the used imaging devices and software in mind. Accounting for systematic difference between methods increases comparability and conversion formulae are provided. Less dense scans did not affect drusen volume measurements in iAMD but decreased sensitivity for medium drusen in eAMD. Trial registration: ClinicalTrials.gov NCT03349801. Registered on 22 November 2017
Characteristics and Spatial Distribution of Structural Features in Age-Related Macular Degeneration: A MACUSTAR Study Report
Purpose: To report the prevalence and topographic distribution of structural characteristics in study participants with age-related macular degeneration (AMD) and controls in the cross-sectional study part of the MACUSTAR study (ClinicalTrials.gov Identifier: NCT03349801). Design: European, multicenter cohort study. Subjects: Overall, 301 eyes of 301 subjects with early (n = 34), intermediate (n = 168), and late AMD (n = 43), as well as eyes without any AMD features (n = 56). Methods: In study eyes with intermediate AMD (iAMD), the presence of structural AMD biomarkers, including pigmentary abnormalities (PAs), pigment epithelium detachment (PED), refractile deposits, reticular pseudodrusen (RPD), hyperreflective foci (HRF), incomplete/complete retinal pigment epithelium (RPE), and outer retinal atrophy (i/cRORA), and quiescent choroidal neovascularization (qCNV) was systematically determined in the prospectively acquired multimodal retinal imaging cross-sectional data set of MACUSTAR. Retinal layer thicknesses and the RPE drusen complex (RPEDC) volume were determined for the total study cohort in spectral-domain (SD) OCT imaging using a deep-learning–based algorithm. Main Outcome Measures: Prevalence and topographic distribution of structural iAMD features. Results: A total of 301 study eyes of 301 subjects with a mean (± standard deviation) age of 71.2 ± 7.20 years (63.1% women) were included. Besides large drusen, the most prevalent structural feature in iAMD study eyes were PA (57.1%), followed by HRF (51.8%) and RPD (22.0%). Pigment epithelium detachment lesions were observed in 4.8%, vitelliform lesions in 4.2%, refractile deposits in 3.0%, and qCNV in 2.4%. Direct precursor lesions for manifest retinal atrophy were detected in 10.7% (iRORA) and 4.2% (cRORA) in iAMD eyes. Overall, the highest RPEDC volume with a median of 98.92 × 10−4 mm³ was found in iAMD study eyes. Spatial analysis demonstrated a predominant distribution of RPD in the superior and temporal subfields at a foveal eccentricity of 1.5 to 2 mm, whereas HRF and large drusen had a distinct topographic distribution involving the foveal center. Conclusions: Detailed knowledge of the prevalence and distribution of structural iAMD biomarkers is vital to identify reliable outcome measure for disease progression. Longitudinal analyses are needed to evaluate their prognostic value for conversion to advanced disease stages. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references
Recommended from our members
Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report
This study aimed to determine the retest variability of quantitative fundus autofluorescence (QAF) in patients with and without age-related macular degeneration (AMD) and evaluate the predictive value of patient reliability indices on retest reliability. A total of 132 eyes from 68 patients were examined, including healthy individuals and those with various stages of AMD. Duplicate QAF imaging was conducted at baseline and 2 weeks later across six study sites. Intraclass correlation (ICC) analysis was used to evaluate the consistency of imaging, and mean opinion scores (MOS) of image quality were generated by two researchers. The contribution of MOS and other factors to retest variation was assessed using mixed-effect linear models. Additionally, a Random Forest Regressor was trained to evaluate the extent to which manual image grading of image quality could be replaced by automated assessment (inferred MOS). The results showed that ICC values were high for all QAF images, with slightly lower values in AMD-affected eyes. The average inter-day ICC was found to be 0.77 for QAF segments within the QAF8 ring and 0.74 for peripheral segments. Image quality was predicted with a mean absolute error of 0.27 on a 5-point scale, and of all evaluated reliability indices, MOS/inferred MOS proved most important. The findings suggest that QAF allows for reliable testing of autofluorescence levels at the posterior pole in patients with AMD in a multicenter, multioperator setting. Patient reliability indices could serve as eligibility criteria for clinical trials, helping identify patients with adequate retest reliability
Recommended from our members
Development and Valuation of a Preference-Weighted Measure in Age-Related Macular Degeneration From the Vision Impairment in Low Luminance Questionnaire—A MACUSTAR Report
Objectives: This study generates VILL-UI (Vision Impairment in Low Luminance - Utility Index), a preference-weighted measure (PWM) derived from the VILL-33 measure for use in patients with age-related macular degeneration (AMD) and valued to generate United Kingdom and German preference weights.
Methods: A PWM consists of a classification system to describe health and utility values for every state described by the classification. The classification was derived using existing data collected as part of the MACUSTAR study, a low-interventional study on AMD, conducted at 20 clinical sites across Europe. Items were selected using psychometric and Rasch analyses, published criteria around PWM suitability, alongside instrument developer views and concept elicitation work that informed VILL-33 development. An online discrete choice experiment (DCE) with duration of the health state was conducted with the United Kingdom and German public. Responses were modeled to generate utility values for all possible health states.
Results: The classification system has 5 items across the 3 domains of VILL-33: reading and accessing information, mobility and safety, and emotional well-being. The DCE samples (United Kingdom: n = 1004, Germany: n = 1008) are broadly representative and demonstrate good understanding of the tasks. The final DCE analyses produce logically consistent and significant coefficients.
Conclusions: This study enables responses to VILL-33 to be directly used to inform economic evaluation in AMD. The elicitation of preferences from both United Kingdom and Germany enables greater application of VILL-UI for economic evaluation throughout Europe. VILL-UI fills a gap in AMD in which generic preference-weighted measures typically lack sensitivity
Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report
Drusen are hallmarks of early and intermediate age-related macular degeneration (AMD) but their quantification remains a challenge. We compared automated drusen volume measurements between different OCT devices. We included 380 eyes from 200 individuals with bilateral intermediate (iAMD, n = 126), early (eAMD, n = 25) or no AMD (n = 49) from the MACUSTAR study. We assessed OCT scans from Cirrus (200 × 200 macular cube, 6 × 6 mm; Zeiss Meditec, CA) and Spectralis (20° × 20°, 25 B-scans; 30° × 25°, 241 B-scans; Heidelberg Engineering, Germany) devices. Sensitivity and specificity for drusen detection and differences between modalities were assessed with intra-class correlation coefficients (ICCs) and mean difference in a 5 mm diameter fovea-centered circle. Specificity was > 90% in the three modalities. In eAMD, we observed highest sensitivity in the denser Spectralis scan (68.1). The two different Spectralis modalities showed a significantly higher agreement in quantifying drusen volume in iAMD (ICC 0.993 [0.991–0.994]) than the dense Spectralis with Cirrus scan (ICC 0.807 [0.757–0.847]). Formulae for drusen volume conversion in iAMD between the two devices are provided. Automated drusen volume measures are not interchangeable between devices and softwares and need to be interpreted with the used imaging devices and software in mind. Accounting for systematic difference between methods increases comparability and conversion formulae are provided. Less dense scans did not affect drusen volume measurements in iAMD but decreased sensitivity for medium drusen in eAMD