272 research outputs found

    'Treatment of the Sportsman's groin': British Hernia Society's 2014 position statement based on the Manchester Consensus Conference

    Get PDF
    <b>Introduction</b> The aim was to produce a multidisciplinary consensus to determine the current position on the nomenclature, definition, diagnosis, imaging modalities and management of Sportsman's groin (SG).<p></p> <b>Methods</b> Experts in the diagnosis and management of SG were invited to participate in a consensus conference held by the British Hernia Society in Manchester, UK on 11–12 October 2012. Experts included a physiotherapist, a musculoskeletal radiologist and surgeons with a proven track record of expertise in this field. Presentations detailing scientific as well as outcome data from their own experiences were given. Records were made of the presentations with specific areas debated openly.<p></p> <b>Results</b> The term ‘inguinal disruption’ (ID) was agreed as the preferred nomenclature with the term ‘Sportsman's hernia’ or ‘groin’ rejected, as no true hernia exists. There was an overwhelming agreement of opinion that there was abnormal tension in the groin, particularly around the inguinal ligament attachment. Other common findings included the possibility of external oblique disruption with consequent small tears noted as well as some oedema of the tissues. A multidisciplinary approach with tailored physiotherapy as the initial treatment was recommended with any surgery involving releasing the tension in the inguinal canal by various techniques and reinforcing it with a mesh or suture repair. A national registry should be developed for all athletes undergoing surgery.<p></p> <b>Conclusions</b> ID is a common condition where no true hernia exists. It should be managed through a multidisciplinary approach to ensure consistent standards and outcomes are achieved

    Impact of Mesh and Fixation on Chronic Inguinal Pain in Lichtenstein Hernia Repair : 5-Year Outcomes from the Finn Mesh Study

    Get PDF
    Objective To find out the mesh fixation technique that minimises chronic pain in Lichtenstein hernioplasty. Summary background data Mesh fixation may affect chronic pain and recurrence after inguinal hernia surgery, but long-term results of comparative trials are lacking. Methods Lichtenstein hernioplasty was performed under local anaesthesia on 625 patients in day care units. The patients were randomised to receive either a cyanoacrylate glue (n = 216), self-gripping mesh (n = 202) or non-absorbable 3-0 polypropylene sutures (n = 216) for the fixation of mesh. A standardised telephone interview or postal questionnaire was conducted 5 years after the index operation. The patients with complaints suggesting recurrence or chronic pain (visual analogue scale >= 3, 0-10) were examined clinically. The rate of occasional pain, chronic severe pain, recurrence, re-operations, daily use of analgesics, overall patient satisfaction and sensation of a foreign object were recorded. Results A total of 82% of patients (n = 514) completed the 5-year audit including 177, 167 and 170 patients in the glue, self-fixation and suture groups, respectively. There were no significant differences in the incidence of pain (7-8%), operated recurrences (2-4%), overall re-operations (4-5%), need for analgesics (1-2%), patient's satisfaction (93-97%) or in the feeling of a foreign object (11-18%) between the study groups. Conclusion The choice of the mesh or fixation method had no effect on the overall long-term outcome, pain or recurrence of hernia. Less penetrating fixation (glue or self-gripping mesh) is a safe option for the fixation of mesh in Lichtenstein hernia repair.Peer reviewe

    Ten-year audit of Lichtenstein hernioplasty under local anaesthesia performed by surgical residents

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To analyse in a prospective trial the long-term results of Lichtenstein hernioplasty performed by surgical trainees.</p> <p>Methods</p> <p>Training of tension-free Lichtenstein hernia operation was started in our ambulatory unit as an outpatient procedure under local anaesthesia in 1996. After performing 36 teaching operations together with residents and their supervising specialist, 281 patients were operated during 1996-2000 either by one senior consultant (n = 141) or by 12 surgical trainees (n = 140). After 10 years, 247 (88%) patients were available for the long-term assessment.</p> <p>Results</p> <p>After one month postoperatively, the rate of wound infections (consultant 1.1%, residents 0.7%) and hematomas (consultant 1.1%, residents 3.0%) were low and not related to surgeon's training level (ns). Only 6 (2.1%) clinically evident recurrences were found after 10 years: two after specialist repair and four after trainee repair (ns). Although one third of the patients reported some discomfort after 3 and 10 years, 93-95% of the patients were very satisfied with the operation, with no statistical difference between the surgeons.</p> <p>Conclusion</p> <p>Ambulatory open mesh repair under local anaesthesia was a safe operation and the long-term results were acceptable among the patients operated by surgical trainees.</p

    Numerical calculations of effective elastic properties of two cellular structures

    Full text link
    Young's moduli of regular two-dimensional truss-like and eye-shape-like structures are simulated by using the finite element method. The structures are the idealizations of soft polymeric materials used in the electret applications. In the simulations size of the representative smallest units are varied, which changes the dimensions of the cell-walls in the structures. A power-law expression with a quadratic as the exponential term is proposed for the effective Young's moduli of the systems as a function of the solid volume fraction. The data is divided into three regions with respect to the volume fraction; low, intermediate and high concentrations. The parameters of the proposed power-law expression in each region are later represented as a function of the structural parameters, unit-cell dimensions. The presented expression can be used to predict structure/property relationship in materials with similar cellular structures. It is observed that the structures with volume fractions of solid higher than 0.15 exhibit the importance of the cell-wall thickness contribution in the elastic properties. The cell-wall thickness is the most significant factor to predict the effective Young's modulus of regular cellular structures at high volume fractions of solid. At lower concentrations of solid, eye-like structure yields lower Young's modulus than the truss-like structure with the similar anisotropy. Comparison of the numerical results with those of experimental data of poly(propylene) show good aggreement regarding the influence of cell-wall thickness on elastic properties of thin cellular films.Comment: 7 figures and 2 table

    Factors predicting chronic pain after open inguinal hernia repair : a regression analysis of randomized trial comparing three different meshes with three fixation methods (FinnMesh Study)

    Get PDF
    Correction: Volume: 22 Issue: 5 Pages: 819-819 DOI: 10.1007/s10029-018-1788-y WOS:000446065400016Chronic pain after inguinal hernioplasty is the foremost side-effect up to 10-30% of patients. Mesh fixation may influence on the incidence of chronic pain after open anterior mesh repairs. Some 625 patients who underwent open anterior mesh repairs were randomized to receive one of the three meshes and fixations: cyanoacrylate glue with low-weight polypropylene mesh (n = 216), non-absorbable sutures with partially absorbable mesh (n = 207) or self-gripping polyesther mesh (n = 202). Factors related to chronic pain (visual analogue scores; VAS ae 30, range 0-100) at 1 year postoperatively were analyzed using logistic regression method. A second analysis using telephone interview and patient records was performed 2 years after the index surgery. At index operation, all patient characteristics were similar in the three study groups. After 1 year, chronic inguinal pain was found in 52 patients and after 2 years in only 16 patients with no difference between the study groups. During 2 years' follow-up, three (0.48%) patients with recurrences and five (0.8%) patients with chronic pain were re-operated. Multivariate regression analysis indicated that only new recurrent hernias and high pain scores at day 7 were predictive factors for longstanding groin pain (p = 0.001). Type of mesh or fixation, gender, pre-operative VAS, age, body mass index or duration of operation did not predict chronic pain. Only the presence of recurrent hernia and early severe pain after index operation seemed to predict longstanding inguinal pain.Peer reviewe

    Scent dogs in detection of COVID-19 : triple-blinded randomised trial and operational real-life screening in airport setting

    Get PDF
    Objective To estimate scent dogs' diagnostic accuracy in identification of people infected with SARS-CoV-2 in comparison with reverse transcriptase polymerise chain reaction (RT-PCR). We conducted a randomised triple-blinded validation trial, and a real-life study at the Helsinki-Vantaa International Airport, Finland. Methods Four dogs were trained to detect COVID-19 using skin swabs from individuals tested for SARS-CoV-2 by RT-PCR. Our controlled triple-blinded validation study comprised four identical sets of 420 parallel samples (from 114 individuals tested positive and 306 negative by RT-PCR), randomly presented to each dog over seven trial sessions. In a real-life setting the dogs screened skin swabs from 303 incoming passengers all concomitantly examined by nasal swab SARS-CoV-2 RT-PCR. Our main outcomes were variables of diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value) for scent dog identification in comparison with RT-PCR. Results Our validation experiments had an overall accuracy of 92% (95% CI 90% to 93%), a sensitivity of 92% (95% CI 89% to 94%) and a specificity of 91% (95% CI 89% to 93%) compared with RT-PCR. For our dogs, trained using the wild-type virus, performance was less accurate for the alpha variant (89% for confirmed wild-type vs 36% for alpha variant, OR 14.0, 95% CI 4.5 to 43.4). In the real-life setting, scent detection and RT-PCR matched 98.7% of the negative swabs. Scant airport prevalence (0.47%) did not allow sensitivity testing; our only SARS-CoV-2 positive swab was not identified (alpha variant). However, ad hoc analysis including predefined positive spike samples showed a total accuracy of 98% (95% CI 97% to 99%). Conclusions This large randomised controlled triple-blinded validation study with a precalculated sample size conducted at an international airport showed that trained scent dogs screen airport passenger samples with high accuracy. One of our findings highlights the importance of continuous retraining as new variants emerge. Using scent dogs may present a valuable approach for high-throughput, rapid screening of large numbers of people.Peer reviewe

    PP/PP-HI/silica nanocomposites for HVDC cable insulation: Are silica clusters beneficial for space charge accumulation?

    Get PDF
    New potential High Voltage Direct Current (HVDC) cable insulation materials based on nanocomposites are developed in this study. The nanocomposites are produced by blending of polypropylene (PP), propylene-ethylene copolymer (PP–HI) and a modified fumed silica (A-silica) in a concentration of 1 and 2 wt %. The A-silica is successfully modified with (3-aminopropyl)triethoxysilane (APTES) via a solvent-free method, as proven by infrared spectroscopy, thermogravimetry and transmission electron microscope mapping. A-silica in the polymer matrix acts as a nucleating agent resulting in an increase of the crystallization temperature of the polymers and a smaller crystal size. Moreover, the silica addition modified the crystals morphology of the unfilled PP/PP-HI blend. The composite containing A-silica with 2 wt% contains bigger-size silica clusters than the composite filled with 1 wt%. The composite with the higher A-silica concentration shows lower space charge accumulation and a lower charge current value. Besides, much deeper traps and lower trap density are observed in the composite with 2 wt% A-silica addition compared to the one with a lower concentration. Surprisingly, the presence of silica clusters with dimensions of more than 200 nm exhibit a positive effect on reducing the space charge accumulation. However, the real cause of this improvement might be due to change of the electron distribution stemming from the amine-amine hydrogen bond formation, or the change of the chain mobility due to the presence of occluded polymer macromolecules constrained inside the high structure silica clusters. Both phenomena may lead to a higher energetic barrier of charge de-trapping, thus increasing the depth of the charge traps

    Optimising the antibiotic treatment of uncomplicated acute appendicitis: a protocol for a multicentre randomised clinical trial (APPAC II trial)

    Get PDF
    DiscussionTo our knowledge, APPAC II trial is the first randomised controlled trial comparing per oral antibiotic monotherapy with intravenous antibiotic therapy continued by per oral antibiotics in the treatment of uncomplicated acute appendicitis. The APPAC II trial aims to add clinical evidence on the debated role of antibiotics as the first-line treatment for a CT-confirmed uncomplicated acute appendicitis as well as to optimise the non-operative treatment for uncomplicated acute appendicitis.</p
    • 

    corecore