7 research outputs found

    Enhanced generation of VUV radiation by four-wave mixing in mercury using pulsed laser vaporization

    Full text link
    The efficiency of a coherent VUV source at 125 nm, based on 2-photon resonant four-wave mixing in mercury vapor, has been enhanced by up to 2 orders of magnitude. This enhancement was obtained by locally heating a liquid Hg surface with a pulsed excimer laser, resulting in a high density vapor plume in which the nonlinear interaction occurred. Energies up to 5 μJ (1 kW peak power) have been achieved while keeping the overall Hg cell at room temperature, avoiding the use of a complex heat pipe. We have observed a strong saturation of the VUV yield when peak power densities of the fundamental beams exceed the GW/cm2 range, as well as a large intensity-dependant broadening (up to ~30 cm-1) of the two-photon resonance. The source has potential applications for high resolution interference lithography and photochemistry

    Effect of grain size and microporosity on the in vivo behaviour of B-tricalcium phosphate scaffolds

    Get PDF
    Defining the most adequate architecture of a bone substitute scaffold is a topic that has received much attention over the last 40 years. However, contradictory results exist on the effect of grain size and microporosity. Therefore, the aim of this study was to determine the effect of these two factors on the in vivo behaviour of β-tricalcium phosphate (β-TCP) scaffolds. For that purpose, β-TCP scaffolds were produced with roughly the same macropore size (≈ 150 μm), and porosity (≈ 80 %), but two levels of microporosity (low: 10 % / high: ≈ 25 %) and grain size (small: 1.3 μm /large: ≈ 3.3 μm). The sample architecture was characterised extensively using materialography, Hg porosimetry, micro-computed tomography (μCT), and nitrogen adsorption. The scaffolds were implanted for 2, 4 and 8 weeks in a cylindrical 5-wall cancellous bone defect in sheep. The histological, histomorphometrical and μCT analysis of the samples revealed that all four scaffold types were almost completely resorbed within 8 weeks and replaced by new bone. Despite the three-fold difference in microporosity and grain size, very few biological differences were observed. The only significant effect at p < 0.01 was a slightly faster resorption rate and soft tissue formation between 4 and 8 weeks of implantation when microporosity was increased. Past and present results suggest that the biological response of this particular defect is not very sensitive towards physico-chemical differences of resorbable bone graft substitutes. As bone formed not only in the macropores but also in the micropores, a closer study at the microscopic and localised effects is necessary

    Ablation-Cooled Material Removal with Ultrafast Bursts of Pulses

    Get PDF
    The use of femtosecond laser pulses allows precise and thermal damage -free removal of material (ablation) with wide-ranging scientificl(1,5), medical(6-11) and industrial applications(12). However, its potential is limited by the low speeds at which material can be removed(1,9-11,13) and the complexity of the associated laser technology. The complexity of the laser design arises from the need to overcome the high pulse energy threshold for efficient ablation. However, the use of more powerful lasers to increase the ablation rate results in unwanted effects such as shielding, saturation and collateral damage from heat accumulation at higher laser powers(6,13,14). Here we circumvent this limitation by exploiting ablation cooling, in analogy to a technique routinely used in aerospace engineering(13,16). We apply ultrafast successions (bursts) of laser pulses to ablate the target material before the residual heat deposited by previous pulses diffuses away from the processing region. Proof-of-principle experiments on various substrates demonstrate that extremely high repetition rates, which make ablation cooling possible, reduce the laser pulse energies needed for ablation and increase the efficiency of the removal process by an order of magnitude over previously used laser parameters(17,18). We also demonstrate the removal of brain tissue at two cubic millimetres per minute and dentine at three cubic millimetres per minute without any thermal damage to the bulk(9,11).Wo
    corecore