4,300 research outputs found

    Timing Control System

    Get PDF
    A timing control system is disclosed which is particularly useful in connection with simulated mortar shells. Special circuitry is provided to assure that the shell does not over shoot, but rather detonates early in case of an improper condition; this ensures that ground personnel will not be harmed by a delayed detonation. The system responds to an externally applied frequency control code which is configured to avoid any confusion between different control modes. A premature detonation routine is entered in case an improper time-setting signal is entered, or if the shell is launched before completion of the time-setting sequence. Special provisions are also made for very early launch situations and improper detonator connections. An alternate abort mode is provided to discharge the internal power supply without a detonation in a manner that can be externally monitored, thereby providing a mechanism for non-destructive testing. The abort mode also accelerates the timing function for rapid testing

    Timing control system

    Get PDF
    A timing control system is disclosed which is particularly useful in connection with simulated mortar shells. Special circuitry is provided to assure that the shell does not overshoot, but rather detonates early in case of an improper condition; this ensures that ground personnel will not be harmed by a delayed detonation. The system responds to an externally applied frequency control code which is configured to avoid any confusion between different control modes. A premature detonation routine is entered in case an improper time-setting signal is entered, or if the shell is launched before completion of the time-setting sequence. Special provisions are also made for very early launch situations and improper detonator connections. An alternate abort mode is provided to discharge the internal power supply without a detonation in a manner that can be externally monitored, thereby providing a mechanism for non-destructive testing. The abort mode also accelerates the timing function for rapid testing

    A fuzzy logic controller for hormone administration using an implantable pump

    Get PDF
    This paper describes the requirements for a Fuzzy Logic Controller for the physiologic administration of hormones by means of a FDA-approved surgically implantable infusion pump. Results of a LabVIEW computer simulation for the administration of insulin for diabetic adult patients as well as human growth hormone for pediatric patients are presented. A VHS video tape of the simulation in action has been prepared and is available for viewing

    Elliptical Combing Motion for Harvesting Bell Peppers

    Get PDF
    A new concept for mechanically harvesting bell peppers, intended specifically for multiple-pass harvesting, utilized spaced horizontal fingers combing vertically upward through plant foliage in an elliptical path alternating from both sides of the row. An apparatus based on this concept was designed and built, and harvest tests were conducted to determine the effect of two main machine operating parameters, vertical picking speed and disk angle. Harvesting performance was evaluated in terms of harvest efficiency, fruit damage, and plant damage as it related to multiple-pass harvesting. Fruit removal, both harvestable size and immature, increased significantly as vertical picking speed increased. Branch breakage also tended to increase as vertical picking speed increased, partially accounting for the increased fruit removal. Fruit damage increased significantly as the disk angle increased. Overall, the average harvest efficiency for the tests was 81% and the average fruit damage was 5.9%

    The Mars Science Laboratory Touchdown Test Facility

    Get PDF
    In the Touchdown Test Program for the Mars Science Laboratory (MSL) mission, a facility was developed to use a full-scale rover vehicle and an overhead winch system to replicate the Skycrane landing event

    The medical student

    Full text link
    The Medical Student was published from 1888-1921 by the students of Boston University School of Medicine

    A matched-pair cluster design study protocol to evaluate implementation of the Canadian C-spine rule in hospital emergency departments: Phase III

    Get PDF
    BACKGROUND: Physicians in Canadian emergency departments (EDs) annually treat 185,000 alert and stable trauma victims who are at risk for cervical spine (C-spine) injury. However, only 0.9% of these patients have suffered a cervical spine fracture. Current use of radiography is not efficient. The Canadian C-Spine Rule is designed to allow physicians to be more selective and accurate in ordering C-spine radiography, and to rapidly clear the C-spine without the need for radiography in many patients. The goal of this phase III study is to evaluate the effectiveness of an active strategy to implement the Canadian C-Spine Rule into physician practice. Specific objectives are to: 1) determine clinical impact, 2) determine sustainability, 3) evaluate performance, and 4) conduct an economic evaluation. METHODS: We propose a matched-pair cluster design study that compares outcomes during three consecutive 12-months "before," "after," and "decay" periods at six pairs of "intervention" and "control" sites. These 12 hospital ED sites will be stratified as "teaching" or "community" hospitals, matched according to baseline C-spine radiography ordering rates, and then allocated within each pair to either intervention or control groups. During the "after" period at the intervention sites, simple and inexpensive strategies will be employed to actively implement the Canadian C-Spine Rule. The following outcomes will be assessed: 1) measures of clinical impact, 2) performance of the Canadian C-Spine Rule, and 3) economic measures. During the 12-month "decay" period, implementation strategies will continue, allowing us to evaluate the sustainability of the effect. We estimate a sample size of 4,800 patients in each period in order to have adequate power to evaluate the main outcomes. DISCUSSION: Phase I successfully derived the Canadian C-Spine Rule and phase II confirmed the accuracy and safety of the rule, hence, the potential for physicians to improve care. What remains unknown is the actual change in clinical behaviors that can be affected by implementation of the Canadian C-Spine Rule, and whether implementation can be achieved with simple and inexpensive measures. We believe that the Canadian C-Spine Rule has the potential to significantly reduce health care costs and improve the efficiency of patient flow in busy Canadian EDs

    Euarchontan opsin variation brings new focus to primate origins

    Get PDF
    Debate on the adaptive origins of primates has long focused on the functional ecology of the primate visual system. For example, it is hypothesized that variable expression of short- (SWS1) and middle-to-long-wavelength sensitive (M/LWS) opsins, which confer color vision, can be used to infer ancestral activity patterns and therefore selective ecological pressures. A problem with this approach is that opsin gene variation is incompletely known in the grandorder Euarchonta, i.e., the orders Scandentia (treeshrews), Dermoptera (colugos), and Primates. The ancestral state of primate color vision is therefore uncertain. Here we report on the genes (OPN1SW and OPN1LW) that encode SWS1 and M/LWS opsins in seven species of treeshrew, including the sole nocturnal scandentian Ptilocercus lowii. In addition, we examined the opsin genes of the Central American woolly opossum (Caluromys derbianus), an enduring ecological analogue in the debate on primate origins. Our results indicate: 1) retention of ultraviolet (UV) sensitivity in C. derbianus and a shift from UV to blue spectral sensitivities at the base of Euarchonta; 2) ancient pseudogenization of OPN1SW in the ancestors of P. lowii, but a signature of purifying selection in those of C. derbianus; and, 3) the absence of OPN1LW polymorphism among diurnal treeshrews. These findings suggest functional variation in color vision of nocturnal mammals and a distinctive visual ecology of early primates, perhaps one that demanded greater spatial resolution under light levels that could support cone-mediated color discrimination

    Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis

    Get PDF
    Background Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify study-level factors that might predict accuracy. Methods We undertook a systematic review, meta-analysis and meta-regression of diagnostic cohort studies that compared US to contrast venography in patients with suspected DVT. We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, and citation lists (1966 to April 2004). Random effects meta-analysis was used to derive pooled estimates of sensitivity and specificity. Random effects meta-regression was used to identify study-level covariates that predicted diagnostic performance. Results We identified 100 cohorts comparing US to venography in patients with suspected DVT. Overall sensitivity for proximal DVT (95% confidence interval) was 94.2% (93.2 to 95.0), for distal DVT was 63.5% (59.8 to 67.0), and specificity was 93.8% (93.1 to 94.4). Duplex US had pooled sensitivity of 96.5% (95.1 to 97.6) for proximal DVT, 71.2% (64.6 to 77.2) for distal DVT and specificity of 94.0% (92.8 to 95.1). Triplex US had pooled sensitivity of 96.4% (94.4 to 97.1%) for proximal DVT, 75.2% (67.7 to 81.6) for distal DVT and specificity of 94.3% (92.5 to 95.8). Compression US alone had pooled sensitivity of 93.8 % (92.0 to 95.3%) for proximal DVT, 56.8% (49.0 to 66.4) for distal DVT and specificity of 97.8% (97.0 to 98.4). Sensitivity was higher in more recently published studies and in cohorts with higher prevalence of DVT and more proximal DVT, and was lower in cohorts that reported interpretation by a radiologist. Specificity was higher in cohorts that excluded patients with previous DVT. No studies were identified that compared repeat US to venography in all patients. Repeat US appears to have a positive yield of 1.3%, with 89% of these being confirmed by venography. Conclusion Combined colour-doppler US techniques have optimal sensitivity, while compression US has optimal specificity for DVT. However, all estimates are subject to substantial unexplained heterogeneity. The role of repeat scanning is very uncertain and based upon limited data
    • …
    corecore