1,073 research outputs found

    On Semantic Similarity in Video Retrieval

    Get PDF

    Noncoherent Space-Time Coding: An Algebraic Perspective

    Get PDF
    Cataloged from PDF version of article.The design of space–time signals for noncoherent block-fading channels where the channel state information is not known a priori at the transmitter and the receiver is considered. In particular, a new algebraic formulation for the diversity advantage design criterion is developed. The new criterion encompasses, as a special case, the well-known diversity advantage for unitary space–time signals and, more importantly, applies to arbitrary signaling schemes and arbitrary channel distributions. This criterion is used to establish the optimal diversity-versus-rate tradeoff for training based schemes in block-fading channels. Our results are then specialized to the class of affine space–time signals which allows for a low complexity decoder. Within this class, space–time constellations based on the threaded algebraic space–time (TAST) architecture are considered. These constellations achieve the optimal diversity-versus-rate tradeoff over noncoherent block-fading channels and outperform previously proposed codes in the considered scenarios as demonstrated by the numerical results. Using the analytical and numerical results developed in this paper, nonunitary space–time codes are argued to offer certain advantages in block-fading channels where the appropriate use of coherent space–time codes is shown to offer a very efficient solution to the noncoherent space–time communication paradigm

    Patterns of knowledge and condom use among population groups: results from the 2005 Ethiopian behavioral surveillance surveys on HIV

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Behavioral surveys help interpret the magnitude of HIV/AIDS. We analyzed indicators of knowledge on HIV/AIDS and condom use among sub populations selected for behavioral surveillance in Ethiopia.</p> <p>Methods</p> <p>We used 2005 HIV/AIDS behavioral data from ten target groups. These were female sex workers, defense forces, police force, pastoralists, truck drivers, intercity bus drivers, road construction workers, teachers, factory workers and people in ANC catchment areas.</p> <p>Results</p> <p>Data from 14,524 individuals were analyzed. The majority were males (63.6%). Overall, knowledge of the three preventive methods, misconceptions and comprehensive knowledge was 57%, 75% and 18.5%, respectively. Female sex workers and the defense force showed some behavioral change in using a condom during the most recent sexual encounter and consistently used a condom with non-regular sexual partners and paying partners. Women, pastoralists and the illiterate were less likely to use condom.</p> <p>Conclusion</p> <p>Misconceptions about the transmission of HIV were high and comprehensive knowledge about HIV & AIDS was low, particularly among pastoralists. Consistent condom use and condom use during the last sexual encounter were high among both female sex workers and defense force employees, both with paying and non-regular sexual partners. This might be a positive sign, though a considerable proportion in each target group did not report using a condom during sex with non-regular partners.</p

    Thyroid Hormone Tests Ordering Practice and Cost-Effectiveness in Samples Referred to International Clinical Laboratories from Addis Ababa Health Facilities

    Get PDF
    BACKGROUND: Thyroid dysfunction accounts for majority of endocrine disorders. In sub-Saharan Africa Graves’ disease and hypothyroidism have accounted for 13.1% and 8.8% while the burden of thyroid disorder has ranged from 6.18 to47.34% among countries in the Arab world. The cost for a primary thyroid test done to evaluate the gland function constituted a large proportion of the public health budget. For instance, 10 million thyroid functions have been done each year by laboratories which cost 30 million UK pounds, and they represent 8% of laboratory charge in the US. When a TSH-only protocol (guideline) was used, 95% of the requests were sufficient for diagnosis without requiring further tests, thereby resulting in 50% savings on FT4 reagent and reducing the annual TFT reagent cost by 25%. This is an original study, and its objective was to assess the ordering pattern of TSH tests and their cost-effectiveness in patients’ samples referred to ICL from Addis Ababa health facilities between July2015 to June 2016METHOD: An institution-based cross-sectional study design was utilized to study the ordering pattern of thyroid function tests using one-year retrospective data from ICL.RESULTS: Thyroid profiles were ordered more frequently (49.5%) compared to TSH only (24.3%). An additional 2625.70 USD was paid by patients for individual components in the profile tests that turned out normal.CONCLUSION: Guidelines advocate TSH as the initial test for thyroid dysfunction, but the use of a combination of tests is more common

    Long-term cortisol levels in hair of children and adolescents with Prader-Willi Syndrome

    Get PDF
    Context: Prader-Willi syndrome (PWS) is characterized by hypothalamic dysfunction. In children with PWS, stress-induced central adrenal insufficiency (CAI) has been described, however, daily life cortisol production may be normal. Hair cortisol concentration (HCC) is a marker of long-term systemic cortisol production. Cortisol awakening response (CAR) is the increase in cortisol level after awakening. A negative CAR might suggest hypothalamic-pituitary-adrenal (HPA)-axis reactivity problems. Little is known about HCC and CAR in children with PWS. Objective: To investigate long-term cortisol levels in hair and CAR in children with PWS. Design: Cross-sectional study. Patients: 41 children with PWS. Setting: Dutch PWS Reference Center. Main outcome measures: HCC and salivary cortisol measured by LCMS. Results: Median (IQR) HCC was 1.90 (1.02–3.30) pg/mg at a median (IQR) age of 14.5 (8.20–19.0) years, with median HCC in age-matched references being 2.63 pg/mg. Five patients (13.2%) had HCC &lt; 2.5th percentile for age and these patients had a repeatedly negative CAR. Median HCC was significantly lower in patients with negative CAR than in patients with normal CAR (1.00 (0.22–1.59) vs. 2.25 (1.47–3.26) pg/mg, p = 0.007). One patient had both HCC &lt; 2.5th percentile and repeatedly low morning salivary cortisol levels and negative CAR, and was diagnosed with adrenal insufficiency by overnight metyrapone test. Conclusions: HCC were normal in the majority of children with PWS. Our data suggest that children with HCC &lt; 2.5th percentile and (repeatedly) negative CAR might possibly have adrenal insufficiency or delayed HPA-axis responsiveness.</p

    Ultrafast pump-probe dynamics in ZnSe-based semiconductor quantum-wells

    Full text link
    Pump-probe experiments are used as a controllable way to investigate the properties of photoexcited semiconductors, in particular, the absorption saturation. We present an experiment-theory comparison for ZnSe quantum wells, investigating the energy renormalization and bleaching of the excitonic resonances. Experiments were performed with spin-selective excitation and above-bandgap pumping. The model, based on the semiconductor Bloch equations in the screened Hartree-Fock approximation, takes various scattering processes into account phenomenologically. Comparing numerical results with available experimental data, we explain the experimental results and find that the electron spin-flip occurs on a time scale of 30 ps.Comment: 10 pages, 9 figures. Key words: nonlinear and ultrafast optics, modeling of femtosecond pump-probe experiments, electron spin-flip tim

    Patterning of ultrathin YBCO nanowires using a new focused-ion-beam process

    Full text link
    Manufacturing superconducting circuits out of ultrathin films is a challenging task when it comes to patterning complex compounds, which are likely to be deteriorated by the patterning process. With the purpose of developing high-Tc_c superconducting photon detectors, we designed a novel route to pattern ultrathin YBCO films down to the nanometric scale. We believe that our method, based on a specific use of a focused-ion beam, consists in locally implanting Ga^{3+} ions and/or defects instead of etching the film. This protocol could be of interest to engineer high-Tc_c superconducting devices (SQUIDS, SIS/SIN junctions and Josephson junctions), as well as to treat other sensitive compounds.Comment: 13 pages, 7 figure

    Eddington-limited X-ray Bursts as Distance Indicators. I. Systematic Trends and Spherical Symmetry in Bursts from 4U 1728-34

    Full text link
    We investigate the limitations of thermonuclear X-ray bursts as a distance indicator for the weakly-magnetized accreting neutron star 4U 1728-34. We measured the unabsorbed peak flux of 81 bursts in public data from the Rossi X-Ray Timing Explorer (RXTE). The distribution of peak fluxes was bimodal: 66 bursts exhibited photospheric radius expansion and were distributed about a mean bolometric flux of 9.2e-8 erg/cm^2/s, while the remaining (non-radius expansion) bursts reached 4.5e-8 erg/cm^2/s, on average. The peak fluxes of the radius-expansion bursts were not constant, exhibiting a standard deviation of 9.4% and a total variation of 46%. These bursts showed significant correlations between their peak flux and the X-ray colors of the persistent emission immediately prior to the burst. We also found evidence for quasi-periodic variation of the peak fluxes of radius-expansion bursts, with a time scale of approximately 40 d. The persistent flux observed with RXTE/ASM over 5.8 yr exhibited quasi-periodic variability on a similar time scale. We suggest that these variations may have a common origin in reflection from a warped accretion disk. Once the systematic variation of the peak burst fluxes is subtracted, the residual scatter is only approximately 3%, roughly consistent with the measurement uncertainties. The narrowness of this distribution strongly suggests that i) the radiation from the neutron star atmosphere during radius-expansion episodes is nearly spherically symmetric, and ii) the radius-expansion bursts reach a common peak flux which may be interpreted as a standard candle intensity.Adopting the minimum peak flux for the radius-expansion bursts as the Eddington flux limit, we derive a distance for the source of 4.4-4.8 kpc.Comment: 9 pages, 7 figures, accepted by ApJ. Minor referee's revisions, also includes 9 newly public X-ray burst

    Friction reducing ability of a poly-l-lysine and dopamine modified hyaluronan coating for polycaprolactone cartilage resurfacing implants

    Get PDF
    Frictional properties of cartilage resurfacing implants should be sufficiently low to limit damaging of the opposing cartilage during articulation. The present study determines if native lubricious molecule proteoglycan 4 (PRG4) can adsorb onto a layer-by-layer bioinspired coating composed of poly-l-lysine (PLL) and dopamine modified hyaluronic acid (HADN) and thereby can reduce the friction between implant and articular cartilage. An ELISA was developed to quantify the amount of immobilized human recombinant (rh)PRG4 after exposure to the PLL-HADN coating. The effect on lubrication was evaluated by comparing the coefficient of friction (CoF) of bare polycaprolactone (PCL) disks to that of PLL-HADN coated PCL disks while articulated against cartilage using a ring-on-disk geometry and a lubricant solution consisting of native synovial fluid components including rhPRG4. The PLL-HADN coating effectively immobilized rhPRG4. The surface roughness of PCL disks significantly increased while the water contact angle significantly decreased after application of the coating. The average CoF measured during the first minute of bare PCL against cartilage exceeded twice the CoF of the PLL-HADN coated PCL against cartilage. After 60 min, the CoF reached equilibrium values which were still significantly higher for bare PCL compared to coated PCL. The present study demonstrated that PCL can effectively be coated with PLL-HADN. Additionally, this coating reduces the friction between PCL and cartilage when a PRG4-rich lubricant is used, similar to the lubricating surface of native cartilage. This makes PLL-HADN coating a promising application to improve the clinical success of PCL-based cartilage resurfacing implants.</p
    • …
    corecore