5 research outputs found

    Revisiting the Sequence Method for Baroreflex Analysis

    Get PDF
    The sequence method is an important approach to assess the baroreflex function, mainly because it is based on the spontaneous fluctuations of beat-by-beat arterial pressure (for example, systolic arterial pressure or SAP) and pulse interval (PI). However, some studies revealed that the baroreflex effectiveness index (BEI), calculated through the sequence method, shows an intriguing oscillatory pattern as function of the delay between SAP and PI. It has been hypothesized that this pattern is related to the respiratory influence on SAP and/or PI variability, limiting the SAP ramps to 3 or 4 beats of length. In this study, this hypothesis was tested by assessing the sequence method using raw (original) and filtered series. Results were contrasted to the well-established transfer function, estimated between SAP and PI. Continuous arterial pressure recordings were obtained from healthy rats (N = 61) and beat-by-beat series of SAP and PI were generated. Low-pass (LP) and high-pass (HP) filtered series of SAP and PI were created by filtering the original series with a cutoff frequency of 0.8 Hz. Original series were analyzed by either the sequence method or cross-spectral analysis (transfer function) at low- (LF) and high- (HF) frequency bands, while filtered series were evaluated only by the sequence method. Baroreflex sensitivity (BRS) and BEI of original series, calculated by sequence method, was highly (85–90%) determined by HP series, with no significant association between original and LP series. A high correlation (>0.7) was found between the BRS estimated from original series (sequence method) and HF band (transfer function), as well as for LP series (sequence method) and LF band (transfer function). These findings confirmed the hypothesis that the sequence method quantifies only the high-frequency components of the baroreflex, neglecting the low-frequency influences, such as the Mayer waves. Therefore, we propose using both the original and LP filtered time series for a broader assessment of the baroreflex function using the sequence method

    Myocardial Infarction Area Quantification using High-Resolution SPECT Images in Rats

    No full text
    FUNDAMENTO: Técnicas de imageamento in vivo permitem avaliar sequencialmente a morfologia e a função dos órgãos em diversos modelos experimentais. Desenvolvemos um dispositivo de adaptação de uma gama-câmara clínica para obter imagens tomográficas por emissão de fótons singulares (SPECT) de alta resolução, baseado em colimador pinhole. OBJETIVO: Determinar a acurácia desse sistema na quantificação da área de infarto miocárdico em ratos. MÉTODOS: Treze ratos Wistar machos (250 g) foram submetidos a infarto do miocárdio por oclusão da artéria coronária esquerda. Após 4 semanas, foram adquiridas imagens tomográficas com o sistema desenvolvido, 1,5 hora após a injeção endovenosa de 555MBq de 99mTc-Sestamibi. Na reconstrução tomográfica, utilizamos software especialmente desenvolvido baseado no algoritmo de Máxima Verossimilhança. Comparamos as médias e analisamos a correlação entre a extensão dos defeitos perfusionais detectados pela cintilografia e a extensão da fibrose miocárdica avaliada pela histologia. RESULTADOS: As imagens apresentaram ótima relação órgão-alvo/fundo, com apropriada visualização das paredes e da cavidade do ventrículo esquerdo. Todos os animais exibindo áreas de infarto foram corretamente identificados pelas imagens de perfusão. Não houve diferença entre a área do infarto medida pelo SPECT (21,1 ± 21,2%) e pela histologia (21,7 ± 22,0%; p = 0,45), obtendo forte correlação entre os valores da área de infarto mensurada pelos dois métodos (r = 0,99; p < 0,0001). CONCLUSÃO: O sistema desenvolvido apresentou resolução espacial adequada e elevada acurácia para detecção e quantificação das áreas de infarto miocárdico, sendo uma opção de baixo custo e grande versatilidade na obtenção de imagens em SPECT de alta resolução de órgãos de pequenos roedores

    Coletânea das experiências de inovação na graduação da Unesp

    No full text
    corecore