584,613 research outputs found

    Dosimetric Analysis of Neural and Vascular Structures in Skull Base Tumors Treated with Stereotactic Radiosurgery.

    Get PDF
    Objective To examine the relationship between the prescribed target dose and the dose to healthy neurovascular structures in patients with vestibular schwannomas treated with stereotactic radiosurgery (SRS). Study Design Case series with chart review. Setting SRS center from 2011 to 2013. Subjects Twenty patients with vestibular schwannomas treated at the center from 2011 to 2013. Methods Twenty patients with vestibular schwannomas were included. The average radiation dose delivered to healthy neurovascular structures (eg, carotid artery, basilar artery, facial nerve, trigeminal nerve, and cochlea) was analyzed. Results Twenty patients with vestibular schwannomas who were treated with fused computed tomography/magnetic resonance imaging-guided SRS were included in the study. The prescribed dose ranged from 10.58 to 17.40 Gy over 1 to 3 hypofractions to cover 95% of the target tumor volume. The mean dose to the carotid artery was 5.66 Gy (95% confidence interval [CI], 4.53-6.80 Gy), anterior inferior cerebellar artery was 8.70 Gy (95% CI, 4.54-12.86 Gy), intratemporal facial nerve was 3.76 Gy (95% CI, 3.04-4.08 Gy), trigeminal nerve was 5.21 Gy (95% CI, 3.31-7.11 Gy), and the cochlea was 8.70 Gy (95% CI, 7.81-9.59 Gy). Conclusions SRS for certain vestibular schwannomas can expose the anterior inferior cerebellar artery (AICA) and carotid artery to radiation doses that can potentially initiate atherosclerotic processes. The higher doses to the AICA and carotid artery correlated with increasing tumor volume. The dose delivered to other structures such as the cochlea and intratemporal facial nerve appears to be lower and much less likely to cause immediate complications when shielded

    Diversity analysis of mangosteen (Garcinia mangostana) irradiated by gamma-ray based on morphological and anatomical characteristics

    Get PDF
    Tujuan penelitian ini adalah meningkatkan keragaman genetik manggis (Garcinia mangostana L.) yang diiradiasi dengan sinar gamma dosis 0 Gy, 20 Gy, 25 Gy, 30 Gy, 35 Gy dan 40 Gy. Bahan tanaman yang digunakan adalah biji yang dikumpulkan dari Kampung Cegal, Desa Karacak, Kecamatan Leuwiliang, Kabupaten Bogor, Jawa Barat. Data dihasilkan dari karakteristik morfologi dan anatomi. Hasil penelitian menunjukkan bahwa peningkatan dosis sinar gamma dapat menghambat pertumbuhan benih, sehingga membutuhkan waktu lebih lama untuk tumbuh dan menurunkan viabilitas benih. Secara morfologi, hal itu juga menurunkan tinggi tanaman, diameter batang, ukuran daun, dan jumlah daun. Secara anatomi, kepadatan stomata berkorelasi positif dengan tinggi tanaman dengan nilai korelasi adalah 90% dan 74%. Iradiasi sinar gamma dapat meningkatkan keragaman morfologi hingga 30%. Pemotongan benih setelah iradiasi dapat meningkatkan keragaman dan tingkat kelangsungan hidup manggis. Kata kunci: Garcinia mangostana, sinar gamma, keragaman genetik

    Radiation therapy combined with intracerebral administration of carboplatin for the treatment of brain tumors

    Get PDF
    Background: In this study we determined if treatment combining radiation therapy (RT) with intracerebral (i.c.) administration of carboplatin to F98 glioma bearing rats could improve survival over that previously reported by us with a 15 Gy dose (5 Gy × 3) of 6 MV photons.Methods: First, in order to reduce tumor interstitial pressure, a biodistribution study was carried out to determine if pretreatment with dexamethasone alone or in combination with mannitol and furosemide (DMF) would increase carboplatin uptake following convection enhanced delivery (CED). Next, therapy studies were carried out in rats that had received carboplatin either by CED over 30 min (20 μg) or by Alzet pumps over 7 d (84 μg), followed by RT using a LINAC to deliver either 20 Gy (5 Gy × 4) or 15 Gy (7.5 Gy × 2) dose at 6 or 24 hrs after drug administration. Finally, a study was carried out to determine if efficacy could be improved by decreasing the time interval between drug administration and RT.Results: Tumor carboplatin values for D and DMF-treated rats were 9.4 ±4.4 and 12.4 ±3.2 μg/g, respectively, which were not significantly different (P = 0.14). The best survival data were obtained by combining pump delivery with 5 Gy × 4 of X-irradiation with a mean survival time (MST) of 107.7 d and a 43% cure rate vs. 83.6 d with CED vs. 30-35 d for RT alone and 24.6 d for untreated controls. Treatment-related mortality was observed when RT was initiated 6 h after CED of carboplatin and RT was started 7 d after tumor implantation. Dividing carboplatin into two 10 μg doses and RT into two 7.5 Gy fractions, administered 24 hrs later, yielded survival data (MST 82.1 d with a 25% cure rate) equivalent to that previously reported with 5 Gy × 3 and 20 μg of carboplatin.Conclusions: Although the best survival data were obtained by pump delivery, CED was highly effective in combination with 20 Gy, or as previously reported, 15 Gy, and the latter would be preferable since it would produce less late tissue effects.peer-reviewe

    Analysis of radiation-induced cell death in head and neck squamous cell carcinoma and rat liver maintained in microfluidic devices

    Get PDF
    Objective The aim of this study was to investigate how head and neck squamous cell carcinoma (HNSCC) tissue biopsies maintained in a pseudo in vivo environment within a bespoke microfluidic device respond to radiation treatment. Study Design Feasibility study. Setting Tertiary referral center. Subjects and Methods Thirty-five patients with HNSCC were recruited, and liver tissue from 5 Wistar rats was obtained. A microfluidic device was used to maintain the tissue biopsy samples in a viable state. Rat liver was used to optimize the methodology. HNSCC was obtained from patients with T1-T3 laryngeal or oropharyngeal SCC; N1-N2 metastatic cervical lymph nodes were also obtained. Irradiation consisted of single doses of between 2 Gy and 40 Gy and a fractionated course of 5×2 Gy. Cell death was assessed in the tissue effluent using the soluble markers lactate dehydrogenase (LDH) and cytochrome c and in the tissue by immunohistochemical detection of cleaved cytokeratin18 (M30 antibody). Results A significant surge in LDH release was demonstrated in the rat liver after a single dose of 20 Gy; in HNSCC, it was seen after 40 Gy compared with the control. There was no significant difference in cytochrome c release after 5 Gy or 10 Gy. M30 demonstrated a dose-dependent increase in apoptotic index for a given increase in single-dose radiotherapy. There was a significant increase in apoptotic index between 1×2 Gy and 5×2 Gy. Conclusion M30 is a superior method compared with soluble markers in detecting low-dose radiation-induced cell death. This microfluidic technique can be used to assess radiation-induced cell death in HNSCC and therefore has the potential to be used to predict radiation response

    Radiation therapy for primary carcinoma of the extrahepatic biliary system. An analysis of 63 cases.

    Get PDF
    From 1976 to 1988, 63 patients received radiation therapy for primary cancers of the extrahepatic biliary system (eight gallbladder and 55 extrahepatic biliary duct). Twelve patients underwent orthotopic liver transplantation. Chemotherapy was administered to 13 patients. Three patients underwent intraluminal brachytherapy alone (range, 28 to 55 Gy). Sixty patients received megavoltage external-beam radiation therapy (range, 5.4 to 61.6 Gy; median, 45 Gy), of whom nine received additional intraluminal brachytherapy (range, 14 to 45 Gy; median, 30 Gy). The median survival of all patients was 7 months. Sixty patients died, all within 39 months of radiation therapy. One patient is alive 11 months after irradiation without surgical resection, and two are alive 50 months after liver transplantation and irradiation. Symptomatic duodenal ulcers developed after radiation therapy in seven patients but were not significantly related to any clinical variable tested. Extrahepatic biliary duct cancers, the absence of metastases, increasing calendar year of treatment, and liver transplantation with postoperative radiation therapy were factors significantly associated with improved survival

    Radiation-induced lowered neurogenesis associated with shortened latency of inhibitory avoidance memory response

    Get PDF
    The neural system is less sensitive to radiation than other late-responding organs and tissues such as the kidney and lung. The generation of new neurons in the adult mammalian brain has been documented in several works. Many studies show that adult hippocampal neurogenesis relates to hippocampal function, in several ways. In this study, we assessed the effect of single and fractionated cobalt radiation on neurogenesis in the dentate gyrus of the hippocampal formation. The irradiation time for delivering 2 Gy (for fractionated dose radiation) and 10 Gy (for single dose radiation) at maximum depth were respectively 1.98 min and 9.92 min. To study the association with memory function we examined inhibitory avoidance memory using a step-through device. Brains were withdrawn and fixed, and then sections were stained with cresyl violet for neurons. We found that a 10 Gy dose can induce lower neurogenesis in the dentate gyrus of the hippocampus (p < 0.05), in such a way that a fractionated dose (5 fractions of 2 Gy) is more effective than a single dose (one fraction of 10 Gy). Moreover, a fractionated dose could reduce step-through latency corresponding to damaged inhibitory avoidance memory (p < 0.05). Synergic action of an anaesthetic drug may be the cause of more reduction of neurogenesis in fractionated irradiated rats. There was no significant difference in latency of the inhibitory avoidance memory response between the single 10 Gy group and the sham group, while fractionated 10 Gy could reduce latency. Different mechanisms of action in the two regimens of irradiation may be a reason

    Comparison of established and emerging biodosimetry assays

    Get PDF
    Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging &gamma;-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3-0.4 days of receipt of samples for the &gamma;-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5-4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and &gamma;-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses &ge;1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools
    • …
    corecore