126 research outputs found

    Nitrogen cycle disruption through the application of de-icing salts on upland highways

    Get PDF
    It is hypothesized that episodic introductions of road salt severely disrupt the soil nitrogen cycle at a range of spatial and temporal scales. A field-scale study has confirmed impacts on the nitrogen cycle in soil, soil solution and river samples. There is evidence that ammonium-N retention on cation exchange sites has been reduced by the presence of sodium ions, and that ammonium-N has been flushed from the exchange sites. Increases in soil pH have been caused in naturally acidic uplands. These have enhanced mineralization of organic-N, especially nitrification, leading to a reduction in the mineralizable-N pool of roadside soils. There is evidence to support the hypothesis that organic matter content has been lowered over decades either through desorption or dispersal processes. Multiple drivers are identified that contribute to the disruption of nitrogen cycling processes, but their relative importance is difficult to quantify unequivocally. The influence of road salt on soil and soil solution declines with distance from the highway, but impacts on water chemistry in a local stream are still strongly evident at some distance from the road

    X-ray Absorption Linear Dichroism at the Ti K-edge of TiO2 anatase single crystal

    Full text link
    Anatase TiO2 (a-TiO2) exhibits a strong X-ray absorption linear dichroism with the X-ray incidence angle in the pre-edge, the XANES and the EXAFS at the titanium K-edge. In the pre-edge region the behaviour of the A1-A3 and B peaks, originating from the 1s-3d transitions, is due to the strong pp-orbital polarization and strong pdp-d orbital mixing. An unambiguous assignment of the pre-edge peak transitions is made in the monoelectronic approximation with the support of ab initio finite difference method calculations and spherical tensor analysis in quantitative agreement with the experiment. It is found that A1 is mostly an on-site 3d-4p hybridized transition, while peaks A3 and B are non-local transitions, with A3 being mostly dipolar and influence by the 3d-4p intersite hybridization, while B is due to interactions at longer range. Finally, peak A2 which was previously assigned to a transition involving pentacoordinated titanium atoms exhibits a quadrupolar angular evolution with incidence angle. These results pave the way to the use of the pre-edge peaks at the K-edge of a-TiO2 to characterize the electronic structure of related materials and in the field of ultrafast XAS where the linear dichroism can be used to compare the photophysics along different axes.Comment: 43 pages, 19 figure

    Structural analysis of ultrafast extended x-ray absorption fine structure with subpicometer spatial resolution: Application to spin crossover complexes

    Get PDF
    We present a novel analysis of time-resolved extended x-ray absorption fine structure (EXAFS) spectra based on the fitting of the experimental transients obtained from optical pump/x-ray probe experiments. We apply it to the analysis of picosecond EXAFS data on aqueous [FeII (bpy)3] 2+, which undergoes a light induced conversion from its low-spin (LS) ground state to the short-lived (τ≈650 ps) excited high-spin (HS) state. A series of EXAFS spectra were simulated for a collection of possible HS structures from which the ground state fit spectrum was subtracted to generate transient difference absorption (TA) spectra. These are then compared with the experimental TA spectrum using a least-squares statistical analysis to derive the structural change. This approach reduces the number of required parameters by cancellation in the differences. It also delivers a unique solution for both the fractional population and the extracted excited state structure. We thus obtain a value of the Fe-N bond elongation in the HS state with subpicometer precision (0.203±0.008 Å). © 2009 American Institute of Physics.This work was funded by the Swiss National Science Foundation via Contract Nos. 620–066145, 200021–107956, PP002–110464, 200020–116023, 200021–105239, and 200020-116533.Peer Reviewe

    Infection intensity-dependent accuracy of reagent strip for the diagnosis of Schistosoma haematobium and estimation of treatment prevalence thresholds

    Get PDF
    BACKGROUND: Reagent strip to detect microhematuria as a proxy for Schistosoma haematobium infections has been considered an alternative to urine filtration for individual diagnosis and community-based estimates of treatment needs for preventive chemotherapy. However, the diagnostic accuracy of reagent strip needs further investigation, particularly at low infection intensity levels. METHODS: We used existing data from a study conducted in Tanzania that employed urine filtration and reagent strip testing for S. haematobium in two villages, including a baseline and six follow-up surveys after praziquantel treatment representing a wide range of infection prevalence. We developed a Bayesian model linking individual S. haematobium egg count data based on urine filtration to reagent strip binary test results available on multiple days and estimated the relation between infection intensity and sensitivity of reagent strip. Furthermore, we simulated data from 3,000 hypothetical populations with varying mean infection intensity to infer on the relation between prevalence observed by urine filtration and the interpretation of reagent strip readings. PRINCIPAL FINDINGS: Reagent strip showed excellent sensitivity even for single measurement reaching 100% at around 15 eggs of S. haematobium per 10 ml of urine when traces on reagent strip were considered positive. The corresponding specificity was 97%. When traces were considered negative, the diagnostic accuracy of the reagent strip was equivalent to urine filtration data obtained on a single day. A 10% and 50% urine filtration prevalence based on a single day sampling corresponds to 11.2% and 48.6% prevalence by reagent strip, respectively, when traces were considered negative, and 17.6% and 57.7%, respectively, when traces were considered positive. CONCLUSIONS/SIGNIFICANCE: Trace results should be included in reagent strip readings when high sensitivity is required, but excluded when high specificity is needed. The observed prevalence of reagent strip results, when traces are considered negative, is a good proxy for prevalence estimates of S. haematobium infection by urine filtration on a single day

    The communication chain of genetic risk: analyses of narrative data exploring proband-provider and proband-family communication in hereditary breast and ovarian cancer

    Get PDF
    Low uptake of genetic services among members of families with hereditary breast and ovarian cancer (HBOC) suggests limitations of proband-mediated communication of genetic risk. This study explored how genetic information proceeds from healthcare providers to probands and from probands to relatives, from the probands' perspectives. Using a grounded-theory approach, we analyzed narrative data collected with individual interviews and focus groups from a sample of 48 women identified as carriers of HBOC-associated pathogenic variants from three linguistic regions of Switzerland. The findings describe the "communication chain", confirming the difficulties of proband-mediated communication. Provider-proband communication is impacted by a three-level complexity in the way information about family communication is approached by providers, received by probands, and followed-up by the healthcare system. Probands' decisions regarding disclosure of genetic risk are governed by dynamic and often contradictory logics of action, interconnected with individual and family characteristics, eventually compelling probands to engage in an arbitrating process. The findings highlight the relevance of probands' involvement in the communication of genetic risk to relatives, suggesting the need to support them in navigating the complexity of family communication rather than replacing them in this process. Concrete actions at the clinical and health system levels are needed to improve proband-mediated communication

    Prevalence and factors associated with chronic use of levothyroxine: A cohort study

    Get PDF
    Importance Levothyroxine prescriptions are rising worldwide. However, there are few data on factors associated with chronic use. Objective To assess the prevalence of chronic levothyroxine use, its rank among other chronic drugs and factors associated with chronic use. To assess the proportion of users outside the therapeutic range of thyroid-stimulating hormone (TSH). Design Cohort study (CoLaus|PsyCoLaus) with recruitment from 2003 to 2006. Follow-ups occurred 5 and 10 years after baseline. Participants A random sample of Lausanne (Switzerland) inhabitants aged 35-75 years. Main outcomes We evaluated the prevalence of chronic levothyroxine use and we then ranked it among the other most used chronic drugs. The ranking was compared to data from health insurance across the country. We assessed the association between each factor and chronic levothyroxine use in multivariable logistic regression models. The proportion of chronic levothyroxine users outside the usual TSH therapeutic range was assessed. Results 4,334 participants were included in the analysis (mean±SD age 62.8±10.4 years, 54.9% women). 166 (3.8%) participants were chronic levothyroxine users. Levothyroxine was the second most prescribed chronic drug after aspirin in the cohort (8.2%) and the third most prescribed when using Swiss-wide insurance data. In multivariable analysis, chronic levothyroxine use was associated with increasing age [odds ratio 1.03, 95% confidence interval 1.01-1.05 per 1-year increase]; female sex [11.87 (5.24-26.89)]; BMI [1.06 (1.02- 1.09) per 1-kg/m2 increase]; number of concomitant drugs [1.22 (1.16-1.29) per 1-drug increase]; and family history of thyroid pathologies [2.18 (1.37-3.48)]. Among chronic levothyroxine users with thyroid hormones assessment (n = 157), 42 (27%) were outside the TSH therapeutic range (17% overtreated and 10% undertreated). Conclusions In this population-based study, levothyroxine ranked second among chronic drugs. Age, female sex, BMI, number of drugs and family history of thyroid pathologies were associated with chronic levothyroxine use. More than one in four chronic users were over- or undertreated

    Comparison between B.R.A.H.M.S PCT direct, a new sensitive point-of-care testing device for rapid quantification of procalcitonin in emergency department patients and established reference methods - a prospective multinational trial

    Get PDF
    BACKGROUND: Procalcitonin (PCT) is increasingly being used for the diagnostic and prognostic work up of patients with suspected infections in the emergency department (ED). Recently, B.R.A.H.M.S PCT direct, the first high sensitive point-of-care test (POCT), has been developed for fast PCT measurement on capillary or venous blood samples. METHODS: This is a prospective, international comparison study conducted in three European EDs. Consecutive patients with suspicion of bacterial infection were included. Duplicate determination of PCT was performed in capillary (fingertip) and venous whole blood (EDTA), and compared to the reference method. The diagnostic accuracy was evaluated by correlation and concordance analyses. RESULTS: Three hundred and three patients were included over a 6-month period (60.4% male, median age 65.2 years). The correlation between capillary or venous whole blood and the reference method was excellent: r2=0.96 and 0.97, sensitivity 88.1% and 93.0%, specificity 96.5% and 96.8%, concordance 93% and 95%, respectively at a 0.25 mug/L threshold. No significant bias was observed (-0.04 and -0.02 for capillary and venous whole blood) although there were 6.8% and 5.1% outliers, respectively. B.R.A.H.M.S PCT direct had a shorter time to result as compared to the reference method (25 vs. 144 min, difference 119 min, 95% CI 110-134 min, p>0.0001). CONCLUSIONS: This study found a high diagnostic accuracy and a faster time to result of B.R.A.H.M.S PCT direct in the ED setting, allowing shortening time to therapy and a more wide-spread use of PCT

    Protocol for evaluating a workplace intervention within the framework of consultations for suffering at work in French-speaking Switzerland.

    Get PDF
    Psychosocial suffering involves diverse human, social and economic costs. Some 34.4% of workers in Switzerland report chronic stress related to their jobs. Medical consultations for suffering at work aim to maintain-or renew-patients' abilities to make decisions and act following a diagnosis of psychological suffering related to their work; they also aim to help workers return to their workstations or remain there. Workplace interventions by consulting occupational physicians can go beyond the subjective issues: they can be offered to employees, in anticipation of a return to work when this appears feasible from the outset. To qualitatively evaluate perceptions of workplace interventions and identify their effects by collecting the verbatim statements of employees and their employers. Qualitative single-centre study of workplace interventions conducted by the Consultation Service for Suffering at Work's occupational physicians for patients seen between January 2015 to December 2017. Nineteen workplace interventions took place, out of 184 different consultations. The verbatim statements of employees and their employers will be collected over a variable timeframe, using semi-structured face-to-face interviews. These will then be recorded, transcribed and analysed. Fourteen patients refused the workplace intervention. Their professional path will be collected for comparison and exploratory purposes. This exploratory research project will provide a better understanding of the issues surrounding work-related psychological suffering and of which strategies support patients most effectively

    Vadose-Zone Alteration of Metaschoepite and Ceramic UO2 in Savannah River Site Field Lysimeters

    Get PDF
    Uranium dioxide (UO2) and metaschoepite (UO3•nH2O) particles have been identified as contaminants at nuclear sites. Understanding their behavior and impact is crucial for safe management of radioactively contaminated land and to fully understand U biogeochemistry. The Savannah River Site (SRS) (South Carolina, USA), is one such contaminated site, following historical releases of U-containing wastes to the vadose zone. Here, we present an insight into the behavior of these two particle types under dynamic conditions representative of the SRS, using field lysimeters (15 cm D x 72 cm L). Discrete horizons containing the different particle types were placed at two depths in each lysimeter (25 cm and 50 cm) and exposed to ambient rainfall for 1 year, with an aim of understanding the impact of dynamic, shallow subsurface conditions on U particle behavior and U migration. The dissolution and migration of U from the particle sources and the speciation of U throughout the lysimeters was assessed after 1 year using a combination of sediment digests, sequential extractions, and bulk and μ-focus X-ray spectroscopy. In the UO2 lysimeter, oxidative dissolution of UO2 and subsequent migration of U was observed over 1–2 cm in the direction of waterflow and against it. Sequential extractions of the UO2 sources suggest they were significantly altered over 1 year. The metaschoepite particles also showed significant dissolution with marginally enhanced U migration (several cm) from the sources. However, in both particle systems the released U was quantitively retained in sediment as a range of different U(IV) and U(VI) phases, and no detectable U was measured in the lysimeter effluent. The study provides a useful insight into U particle behavior in representative, real-world conditions relevant to the SRS, and highlights limited U migration from particle sources due to secondary reactions with vadose zone sediments over 1 year.Peer reviewe

    Nanoscale depth-resolved coherent femtosecond motion in laser-excited bismuth

    Get PDF
    We employ grazing-incidence femtosecond x-ray diffraction to characterize the coherent, femtosecond laser-induced lattice motion of a bismuth crystal as a function of depth from the surface with a temporal resolution of 193 +/- 8 fs. The data show direct consequences on the lattice motion from carrier diffusion and electron-hole interaction, allowing us to estimate an effective diffusion rate of D=2.3 +/- 0.3 cm(2)/s for the highly excited carriers and an electron-hole interaction time of 260 +/- 20 fs
    corecore