4,449 research outputs found
Long-term observations of Uranus and Neptune at 90 GHz with the IRAM 30m telescope - (1985 -- 2005)
The planets Uranus and Neptune with small apparent diameters are primary
calibration standards. We investigate their variability at ~90 GHz using
archived data taken at the IRAM 30m telescope during the 20 years period 1985
to 2005. We calibrate the planetary observations against non-variable secondary
standards (NGC7027, NGC7538, W3OH, K3-50A) observed almost simultaneously.
Between 1985 and 2005, the viewing angle of Uranus changed from south-pole to
equatorial. We find that the disk brightness temperature declines by almost 10%
(~2sigma) over this time span indicating that the south-pole region is
significantly brighter than average. Our finding is consistent with recent
long-term radio observations at 8.6 GHz by Klein & Hofstadter (2006). Both data
sets do moreover show a rapid decrease of the Uranus brightness temperature
during the year 1993, indicating a temporal, planetary scale change. We do not
find indications for a variation of Neptune's brightness temperature at the 8%
level. If Uranus is to be used as calibration source, and if accuracies better
than 10% are required, the Uranus sub-earth point latitude needs to be taken
into account.Comment: accepted for publication in A&
The critical sensor: a new type of evanescent wave immunosensor
A new planar waveguide immunosensor has been developed in which adsorption at a surface, changing the refractive index contrast, is measured. In this ¿critical¿ sensor the change in the effective refractive index contrast is transducted to a shift of the critical reflection angle. The sensor's response after a specific binding of antigens to antibodies is discussed theoretically. In addition, an experimental sensitivity evaluation on the basis of several immunosensing experiments is presented. The obtained lower detection limit is 2 × 10¿2 nm in adlayer growth, equivalent to 12 pg/mm2 of analyte coverage. This sensitivity is comparable to the performance of the surface plasmon resonance sensors or the grating coupler sensors. However, the ¿critical¿ sensor has some advantages. These are mainly the ease of fabrication and adjustment prior to a measurement, and the fact for an experiment no metal layer has to be used
Inorganic separator for a high temperature silver-zinc battery
Electrode design, inorganic separators, and performance tests of multiplate five ampere-hour silver-zinc battery cel
Development of a Translator from LLVM to ACL2
In our current work a library of formally verified software components is to
be created, and assembled, using the Low-Level Virtual Machine (LLVM)
intermediate form, into subsystems whose top-level assurance relies on the
assurance of the individual components. We have thus undertaken a project to
build a translator from LLVM to the applicative subset of Common Lisp accepted
by the ACL2 theorem prover. Our translator produces executable ACL2 formal
models, allowing us to both prove theorems about the translated models as well
as validate those models by testing. The resulting models can be translated and
certified without user intervention, even for code with loops, thanks to the
use of the def::ung macro which allows us to defer the question of termination.
Initial measurements of concrete execution for translated LLVM functions
indicate that performance is nearly 2.4 million LLVM instructions per second on
a typical laptop computer. In this paper we overview the translation process
and illustrate the translator's capabilities by way of a concrete example,
including both a functional correctness theorem as well as a validation test
for that example.Comment: In Proceedings ACL2 2014, arXiv:1406.123
Skin blood flow changes during apneic spells in preterm infants
Changes in skin blood flow during apneic spells were determined in 18 preterm infants using a diode laser Doppler flow meter without light conducting fibres. Heart rate, nasal air flow, impedance pneumography, skin and incubator temperature and laser Doppler skin blood flow were recorded simultaneously in each infant. During 212 apneic spells with a duration of 11.6 ± 7.5 s (mean ± S.D.) (range 6.0–48.0 s), the laser Doppler skin blood flow was measured. In all children except one, the majority of the apneic spells was associated with a decrease in skin blood flow. During 155 apneic spells (73%) skin blood flow decreased significantly P < 0.025), the maximum decrease being 16.7 ± 14.8%, 28.5 ± 23.9% and 18.9 ± 16.1% (mean ± S.D.) for central, obstructive and mixed apneic spells, respectively. The decrease in skin blood flow started immediately after the beginning of apneic spells in 71%, the rest started with a mean delay of 3.4 s (range 0.1–7.0 s). No relation was found between the decrease in skin blood flow and the duration of the apneic spells. Thirty-four percent of the apneic spells were accompanied by bradycardia. In apneic spells accompanied by bradycardia the decrease in skin blood flow was not related to the fall in heart rate
A 1200-micron MAMBO survey of ELAISN2 and the Lockman Hole - I. Maps, sources and number counts
The definitive version is available at www.blackwell-synergy.com '.--Copyright Blackwell Publishing. DOI : 10.1111/j.1365-2966.2004.08235.xWe present a deep, new 1200μm survey of the ELAISN2 and Lockman Hole fields using the Max Planck Millimeter Bolometer array (MAMBO). The areas surveyed are 160 arcmin2 in ELAISN2 and 197 arcmin2 in the Lockman Hole, covering the entire SCUBA ‘8mJy Survey’. In total, 27 (44) sources have been detected at a significance 4.0 ( 3.5 ). The primary goals of the survey were to investigate the reliability of (sub)millimetre galaxy (SMG) samples, to analyse SMGs using flux ratios sensitive to redshift at z > 3, and to search for ‘SCUBA drop-outs’, i.e. galaxies at z >> 3. We present the 1200μm number counts and find evidence of a fall at bright flux levels. Employing parametric models for the evolution of the local 60μm IRAS luminosity function (LF), we are able to account simultaneously for the 1200 and 850μm counts, suggesting that the MAMBO and SCUBA sources trace the same underlying population of high-redshift, dust-enshrouded galaxies. From a nearest-neighbour clustering analysis we find tentative evidence that themost significantMAMBO sources come in pairs, typically separated by 23′′. Our MAMBO observations unambiguously confirm around half of the SCUBA sources. In a robust sub-sample of 13 SMGs detected by both MAMBO and SCUBA at a significance 3.5 , only one has no radio counterpart. Furthermore, the distribution of 850/1200μmflux density ratios for this sub-sample is consistent with the spectroscopic redshift distribution of radio-detected SMGs (Chapman et al. 2003). Finally, we have searched for evidence of a high-redshift tail of SMGs amongst the 18 MAMBO sources which are not detected by SCUBA. While we cannot rule out that some of them are SCUBA drop-outs at z >> 3, their overall 850-to-1200μm flux distribution is statistically indistinguishable from that of the 13 SMGS which were robustly identified by both MAMBO and SCUBA.Peer reviewe
Wide-field mid-infrared and millimetre imaging of the high-redshift radio galaxy, 4C41.17
We present deep 350- and 1200-micron imaging of the region around 4C41.17 --
one of the most distant (z = 3.792) and luminous known radio galaxies --
obtained with the Submillimeter High Angular Resolution Camera (SHARC-II) and
the Max Planck Millimeter Bolometer Array (MAMBO). The radio galaxy is robustly
detected at 350- and 1200-micron, as are two nearby 850-micron-selected
galaxies; a third 850-micron source is detected at 350-micron and coincides
with a ~ 2-sigma feature in the 1200-micron map. Further away from the radio
galaxy an additional nine sources are detected at 1200-micron, bringing the
total number of detected (sub)millimeter selected galaxies (SMGs) in this field
to 14. Using radio images from the Very Large Array (VLA) and Spitzer
mid-infrared (mid-IR) data, we find statistically robust radio and/or 24-micron
counterparts to eight of the 14 SMGs in the field around 4C41.17. Follow-up
spectroscopy with Keck/LRIS has yielded redshifts for three of the eight
robustly identified SMGs, placing them in the redshift range 0.5 < z < 2.7,
i.e. well below that of 4C41.17. We infer photometric redshifts for a further
four sources using their 1.6-micron (rest-frame) stellar feature as probed by
the IRAC bands; only one of them is likely to be at the same redshift as
4C41.17. Thus at least four, and as many as seven, of the SMGs within the
4C41.17 field are physically unrelated to the radio galaxy. With the redshift
information at hand we are able to constrain the observed over-densities of
SMGs within radial bins stretching to R=50 and 100" (~ 0.4 and ~ 0.8Mpc at z ~
3.8) from the radio galaxy to ~ 5x and ~ 2x that of the field, dropping off to
the background value at R=150". [Abridged]Comment: 20 pages, 9 figures, accepted for publication in MNRA
Two small-volume electrochemical cells for the measurement of surface enhanced Raman scattering
Two electrochemical cells, for performing surface enhanced Raman scattering (SERS), with submillilitre volumes are presented. One of the cells is especially developed for use in a Raman microspectrometer. The smallest cell uses only 80 mu l of sample. SER measurements are performed on 2*10-3 M adenine
- …