159 research outputs found

    Effect of immediate dentine sealing on the aging and fracture strength of lithium disilicate inlays and overlays

    Get PDF
    Objectives: The objectives of this study were to compare the in vitro, laboratory aging, fracture strength, failure mode and reparability of molars restored with lithium disilicate inlays and overlays in conjunction with or without immediate dentin sealing (IDS). Methods: Forty extracted, sound human molars were selected and divided into four groups: 1) Inlays with IDS; 2) Inlays without IDS; 3) Overlays with IDS; 4) Overlays without IDS. Standard MOD preparations were made (3 mm wide, 5 mm deep) and in groups 2 and 4, all the cusps were reduced by 2 mm. Directly following tooth preparation, IDS was applied in specimens belonging to groups 1 and 3. The indirect restorations were luted with a heated composite. The restored teeth were subsequently challenged during aging (1.2 million cycles) and thermocycling loading (8000 cycles, 5–55 degrees C). Subsequently, the fracture strength was tested by a load to failure test at 45°. A failure analysis was performed using light- and scanning electron microscopy. The results were analyzed using two-way ANOVA and a Fisher exact test. Results: Mean fracture load + SD (N) were: Group 1 (n = 12): 1610 ± 419; Group 2 (n = 12): 1115 ± 487; Group 3 (n = 12): 2011 ± 496; Group 4 (n = 12): 1837 ± 406. Teeth restored with an onlay were stronger than those restored with an inlay restoration (p <.001). Teeth with IDS were stronger overall than those without IDS (p =.026). The interaction between preparation type and the mode of dentin conditioning had no statistically significant influence on fracture strength (p =.272). Subsequently, custom hypothesis tests showed that there was no statistically significant difference in fracture strength between inlays with IDS and overlays without IDS (p =.27). Overlays tend to fail in a more destructive, non-reparable way (p =.003). Significance: Both variables IDS and overlay preparation improve overall fracture strength. Inlays with IDS and overlays without IDS didn't differ in fracture strength. Both inlays and overlays are strong enough to withstand physiological chewing forces

    Clinical performance of direct composite resin versus indirect restorations on endodontically treated posterior teeth:A systematic review and meta-analysis

    Get PDF
    STATEMENT OF PROBLEM: High-level evidence concerning the restoration of endodontically treated posterior teeth by means of direct composite resin or indirect restorations is lacking. PURPOSE: The purpose of this systematic review and meta-analysis was to analyze the current literature on the direct and indirect restoration of endodontically treated posterior teeth. MATERIAL AND METHODS: Databases MEDLINE, CENTRAL, and EMBASE were screened. Risk of bias was assessed by using the ROB2 tool for RCTs and the ROBINS-I tool for prospective and retrospective clinical studies. Randomized clinical trials (RCTs) and prospective and retrospective studies comparing direct composite resin and indirect restorations on endodontically treated posterior teeth were included. Outcomes were tooth and restoration survival. A meta-analysis was conducted for tooth retention and restorative success. RESULTS: Twenty-two studies were included (2 RCTs, 3 prospective, and 17 retrospective). Over the short term (2.5 to 3 years), low-quality evidence suggested no difference in tooth survival. For the prospective and retrospective clinical trials, the overall risk of bias was serious to critical from the risk of confounding because of a difference in restorative indication: Direct restorations were fabricated when one marginal ridge remained or when tooth prognosis was unfavorable. For short-term restorative success, low-quality evidence suggested no difference between the direct and indirect restorations. CONCLUSIONS: For the short term (2.5 to 3 years), low-quality evidence suggests no difference in tooth survival or restoration quality. To assess the influence of the type of restoration on the survival and restorative success of endodontically treated posterior teeth, clinical trials that control for the amount of coronal tooth tissue and other baseline characteristics are needed

    Dimensional changes of CAD/CAM polymer crowns after water aging - An in vitro experiment

    Get PDF
    Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) polymers can potentially replace traditional materials used for manufacturing indirect restorations. In 2012, Lava Ultimate (LU) was introduced as a highly suitable material for implant-supported single crowns. Three years after its introduction, the manufacturer issued a change in indication for the material, implying that they no longer considered the material to be suitable for crown indications due to debonding issues. A clinical trial with implant-borne Lava Ultimate crowns bonded to zirconia abutments revealed that 80 percent of the LU crowns showed debonding from the abutment within one year, whereas no debonding occurred when an alternative full-ceramic restoration material was used. These results suggest that the material itself had been the cause of the debonding. However, the exact reason for the debonding remained unclear. Water uptake in resin methacrylates like LU is known to cause dimensional changes resulting in mechanical stress on the RelyX Ultimate (RU) cement. The purpose of this study is to quantify the dimensional changes in LU caused by water uptake and relate these dimensional changes to the failure of the RU cement. Twenty-five identical LU-crowns were divided into three groups. 10 LU-crowns with abutment and 10 crowns without abutments were stored in water for 23 days and were only removed for measurement. Five crowns served as a control to calibrate the measurements. The internal diameter was measured eight times with a TS 460 Heidenhain touch probe. For visualization purposes, one crown was also 3D scanned before and after water treatment. The results showed that after 23 days in water the mean increase in diameter for the groups with and without abutment was 36.6 μm (SD = 35,1) and 36.7 μm (SD = 26,5) respectively. Mixed effects modelling indicated no significant between-group differences at any time point. Exposure of LU to water results in dimensional changes causing mechanical stress on the crown-abutment complex. It can be estimated that RU cement fails after an expansion of more than 4 μm. Within the limitations of this in vitro study, it can be concluded that the dimensional changes induced by water uptake can cause debonding issues. As more CAD/CAM polymers for restorative purposes are expected to be developed, the results of this study should stimulate manufacturers to quantify their products' dimensional changes in a wet environment before market release

    Differential Kinetics of Aspergillus nidulans and Aspergillus fumigatus Phagocytosis

    Get PDF
    Acknowledgements: The authors would like to acknowledge Fraser P. Coxon and Ian Ganley for providing LC3-GFP-mCherry BMDMs. M.S.G. was supported by an FEMS research grant and F.L.v.d.V. was supported by ZonMW under the name EURO-CMC frame of E-Rare-2, the ERA-Net for Research on Rare Diseases.Peer reviewedPublisher PD

    Influence of Deep Margin Elevation and preparation design on the fracture strength of indirectly restored molars

    Get PDF
    The objectives of this in-vitro study were to investigate the influence of Deep Margin Elevation (DME) and the preparation design (cusp coverage) on the fracture strength and repairability of CAD/CAM manufactured lithium disilicate (LS2) restorations on molars. Sound extracted human molars (n = 60) were randomly divided into 4 groups (n = 15) (inlay without DME (InoD); inlay with DME (IWD); onlay without DME (OnoD); onlay with DME (OnWD)). All samples were aged (1.2 × 106 cycles of 50N, 8000 cycles of 5–55 °C) followed by oblique static loading until fracture. Fracture strength was measured in Newton and the fracture analysis was performed using a (scanning electron) microscope. Data was statistically analyzed using two-way ANOVA and contingency tables. DME did not affect the fracture strength of LS2 restorations to a statistically significant level (p =.15). Onlays were stronger compared to inlays (p =.00). DME and preparation design did not interact (p =.97). However, onlays with DME were significantly stronger than inlays without DME (p =.00). More repairable fractures were observed among inlays (p =.00). Catastrophic, crown-root fractures were more prevalent in onlays (p =.00). DME did not influence repairability of fractures or fracture types to a statistically significant level (p &gt;.05). Within the limitations of this in-vitro study, DME did not statistical significantly affect the fracture strength, nor the fracture type or repairability of LS2 restorations in molars. Cusp coverage did increase the fracture strength. However, oblique forces necessary to fracture both inlays and onlays, either with or without DME, by far exceeded the bite forces that can be expected under physiological clinical conditions. Hence, both inlays and onlays are likely to be fracture resistant during clinical service.</p

    Influence of the ceramic translucency on the relative degree of conversion of a direct composite and dual-curing resin cement through lithium disilicate onlays and endocrowns

    Get PDF
    INTRODUCTION: The goal of this study was to investigate the influence of the ceramic translucency, restoration type and polymerization time on the relative degree of conversion of a dual-curing resin cement and a conventional microhybrid resin composite using a high-power light-curing device. METHODS AND MATERIALS: Two 4.0 mm thick onlay (O) and two 7.5 mm thick endocrown (E) lithium disilicate restorations in high and low translucency (HT/LT) were fabricated on a decapitated molar. The pulp chamber was prepared to accommodate a 2 mm layer of a microhybrid resin composite (MHC) or dual-curing resin cement (DCC). Composite specimens were light-cured (n = 15; 1200 mW/cm2) without or through an onlay or endocrown restoration. Fourier-transform infrared spectroscopy (FTIR) absorbance curves were collected for the same composite specimen after 3 × 20, 3 × 40, 3 × 60 and 3 × 90 s of light-curing. The relative degree of conversion (DC%) was calculated and results analyzed using Kruskal-Wallis test and Friedman's ANOVA. Alpha was set at 0.05. RESULTS: After 3 × 60 s, the DC of MHC was significantly lower (p = 0.03; r = 0.61) under LT/EC restorations (Mdn: 77.8%) than HT/EC restorations (Mdn: 95.2%). DC of the DCC was not significantly affected by the ceramic translucency or restoration type. MHC had a significant higher DC than DCC under the HT/O, LT/O and HT/E restorations. There were no significant differences between MHC and DCC cured through LT/E restorations. CONCLUSION: DC for DCC was not significantly affected by the ceramic translucency or restoration type. DC for MHC was significantly lower for LT/EC than HT/EC restorations after 3 × 60s polymerization, but not different for the high translucent restorations and low translucent onlays. CLINICAL RELEVANCE: the use of light-curing microhybrid composite for bonding high translucent onlays and endocrowns and low translucent onlays seems feasible

    Randomized clinical trial on the survival of lithium disilicate posterior partial restorations bonded using immediate or delayed dentin sealing after 3 years of function

    Get PDF
    Objectives: The survival and success rate and the quality of survival of partial ceramic restorations bonded employing Immediate (IDS) or Delayed Dentin Sealing (DDS) in vital molar teeth were evaluated in a randomized clinical trial with within-subject comparison study.Materials and methods: 30 patients received two lithium disilicate ceramic (IPS-e.max press, Ivoclar Vivadent) partial restorations on vital first or second molar teeth (N = 60). The two teeth randomly received either IDS (test group, n = 30) or DDS (control group, n = 30). Partial ceramic restorations were luted (Variolink Ultra, Ivoclar Vivadent) two weeks after preparation. Evaluations were performed at 1 week, 12 months and 36 months post-operatively, using qualitative (FDI) criteria. Representative failures were evaluated microscopically (SEM) and by means of simplified qualitative fractography analysis.Results: One absolute failure occurred in the DDS group due to (secondary) caries. The overall survival rate according to Kaplan-Meier after 3 years was 98.3% (FDI criteria score 1-4, n = 59) and the overall success rate was 85% (FDI criteria score 1-3, n = 51), with no significant difference between restorations in the IDS and DDS group (p = 0.32; Kaplan-Meier, Log Rank (Mantel-Cox), CI = 95%). For the quality of the survival, no statistically significant differences were found between IDS and DDS (p = 0.7; Kaplan-Meier, Log Rank (Mantel-Cox), CI = 95%) restorations on any follow-up timepoints for any of the FDI criteria (Wilcoxon, McNemar, p &gt; 0.05).Conclusion: Adhesively luted partial ceramic restorations in vital molar teeth have a good prognosis, however IDS did not show any differences in success and survival rates after 3 years of function.</p

    Effect of preparation design on fracture strength of compromised molars restored with lithium disilicate inlay and overlay restorations: An in vitro and in silico study

    Get PDF
    PURPOSE: The objective of this study was to determine the influence of different preparation designs on the fracture strength, failure type, repairability, formation of polymerization-induced cracks, and tooth deformation of structurally compromised molars restored with lithium disilicate inlays and overlays in combination with Immediate Dentin Sealing (IDS). MATERIAL AND METHODS: Human molars (N = 64) were randomly assigned to four different preparation designs: Undermined Inlay (UI), Extended Inlay (EI), Restricted Overlay (RO), and Extended Overlay (EO). The teeth were restored using lithium disilicate partial restorations and subjected to thermomechanical fatigue in a chewing simulator (1,2 × 10 (Mondelli et al., 2007) cycles on 50 N, 8000x 5-55 °C), followed by load to failure testing. In silico finite element analysis was conducted to assess tooth deformation. Polymerization-induced cracks were evaluated using optical microscopy and transillumination. Fracture strengths were statistically analyzed using a Kruskal-Wallis test, while the failure mode, repairability, and polymerization cracks were analyzed using Fisher exact test. RESULTS: The propagation of polymerization-induced cracks did not significantly differ among preparation designs. All specimens withstood chewing simulator fatigue, with no visible cracks in teeth or restorations. Fracture strength was significantly influenced by preparation design, with restricted overlay (RO) showing higher fracture strength compared to extended inlay (EI) (p = .042). Tooth deformation and fracture resistance correlated between in vitro and in silico analyses). UI exhibited a statistically less destructive failure pattern than EO (p < .01) and RO (p = .036). No statistically significant influence of the preparation design on repairability was observed. Groups with higher repairability rates experienced increased tooth deformation, leading to less catastrophic failures. CONCLUSIONS: The preparation design affected the fracture strength of compromised molars restored with lithium disilicate inlays and overlays, with significantly lower fracture strength for an extended inlay. The failure pattern of lithium disilicate overlays is significantly more destructive than that of undermined and extended inlays. The finite element analysis showed more tooth deformation in the inlay restorations, with lower forces in the roots, leading to less destructive fractures. Since cusp coverage restorations fracture in a more destructive manner, this study suggests the undermined inlay preparation design as a viable option for restoring weakened cusps

    Clinical longevity of intracoronal restorations made of gold, lithium disilicate, leucite, and indirect resin composite:a systematic review and meta-analysis

    Get PDF
    OBJECTIVES: The aim of this systematic review and meta-analysis is to assess the comparative clinical success and survival of intracoronal indirect restorations using gold, lithium disilicate, leucite, and indirect composite materials.MATERIAL AND METHODS: This systematic review and meta-analysis were conducted following the Cochrane Handbook for Systematic Reviews of Interventions and PRISMA guidelines. The protocol for this study was registered in PROSPERO (registration number: CRD42021233185). A comprehensive literature search was conducted across various databases and sources, including PubMed/Medline, Embase, Cochrane Library, Web of Science, ClinicalTrials.gov, and gray literature. A total of 7826 articles were screened on title and abstract. Articles were not excluded based on the vitality of teeth, the language of the study, or the observation period. The risk difference was utilized for the analyses, and a random-effects model was applied. All analyses were conducted with a 95% confidence interval (95% CI). The calculated risk differences were derived from the combined data on restoration survival and failures obtained from each individual article. The presence of heterogeneity was assessed using the I2 statistic, and if present, the heterogeneity of the data in the articles was evaluated using the non-parametric chi-squared statistic (p &lt; 0.05).RESULTS: A total of 12 eligible studies were selected, which included 946 restorations evaluated over a minimum observation period of 1 year and a maximum observation period of 7 years. Results of the meta-analysis indicated that intracoronal indirect resin composite restorations have an 18% higher rate of failure when compared to intracoronal gold restorations over 5-7 years of clinical service (risk difference =  - 0.18 [95% CI: - 0.27, - 0.09]; p = .0002; I2 = 0%). The meta-analysis examining the disparity in survival rates between intracoronal gold and leucite restorations could not be carried out due to methodological differences in the studies.CONCLUSIONS: According to the currently available evidence, medium-quality data indicates that lithium disilicate and indirect composite materials demonstrate comparable survival rates in short-term follow-up. Furthermore, intracoronal gold restorations showed significantly higher survival rates, making them a preferred option over intracoronal indirect resin-composite restorations. Besides that, the analysis revealed no statistically significant difference in survival rates between leucite and indirect composite restorations. The short observation period, limited number of eligible articles, and low sample size of the included studies were significant limitations.CLINICAL SIGNIFICANCE: Bearing in mind the limitations of the reviewed literature, this systematic review and meta-analysis help clinicians make evidence-based decisions on how to restore biomechanically compromised posterior teeth.</p
    corecore