372 research outputs found

    Inbuilt Mechanisms for Overcoming Functional Problems Inherent in Hepatic Microlobular Structure

    Get PDF
    This paper is funded by an MRC/EPSRC Discipline Bridging Initiative Grant (G0502256-77947) to W. Wan

    Material parameter estimation and hypothesis testing on a 1D viscoelastic stenosis model: Methodology

    Get PDF
    This is the post-print version of the final published paper that is available from the link below. Copyright @ 2013 Walter de Gruyter GmbH.Non-invasive detection, localization and characterization of an arterial stenosis (a blockage or partial blockage in the artery) continues to be an important problem in medicine. Partial blockage stenoses are known to generate disturbances in blood flow which generate shear waves in the chest cavity. We examine a one-dimensional viscoelastic model that incorporates Kelvin–Voigt damping and internal variables, and develop a proof-of-concept methodology using simulated data. We first develop an estimation procedure for the material parameters. We use this procedure to determine confidence intervals for the estimated parameters, which indicates the efficacy of finding parameter estimates in practice. Confidence intervals are computed using asymptotic error theory as well as bootstrapping. We then develop a model comparison test to be used in determining if a particular data set came from a low input amplitude or a high input amplitude; this we anticipate will aid in determining when stenosis is present. These two thrusts together will serve as the methodological basis for our continuing analysis using experimental data currently being collected.National Institute of Allergy and Infectious Diseases, Air Force Office of Scientific Research, Department of Education, and Engineering and Physical Sciences Research Council

    High-order space-time finite element schemes for acoustic and viscodynamic wave equations with temporal decoupling

    Get PDF
    Copyright @ 2014 The Authors. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.We revisit a method originally introduced by Werder et al. (in Comput. Methods Appl. Mech. Engrg., 190:6685–6708, 2001) for temporally discontinuous Galerkin FEMs applied to a parabolic partial differential equation. In that approach, block systems arise because of the coupling of the spatial systems through inner products of the temporal basis functions. If the spatial finite element space is of dimension D and polynomials of degree r are used in time, the block system has dimension (r + 1)D and is usually regarded as being too large when r > 1. Werder et al. found that the space-time coupling matrices are diagonalizable over inline image for r ⩽100, and this means that the time-coupled computations within a time step can actually be decoupled. By using either continuous Galerkin or spectral element methods in space, we apply this DG-in-time methodology, for the first time, to second-order wave equations including elastodynamics with and without Kelvin–Voigt and Maxwell–Zener viscoelasticity. An example set of numerical results is given to demonstrate the favourable effect on error and computational work of the moderately high-order (up to degree 7) temporal and spatio-temporal approximations, and we also touch on an application of this method to an ambitious problem related to the diagnosis of coronary artery disease

    Ultrasound Assessment of the Relation Between Local Hemodynamic Parameters and Plaque Morphology

    Get PDF
    202009 bcrcVersion of RecordPublishe

    Detection and Localization of Myocardial Infarction Based on Multi-Scale ResNet and Attention Mechanism

    Get PDF
    PURPOSE: Myocardial infarction (MI) is one of the most common cardiovascular diseases, frequently resulting in death. Early and accurate diagnosis is therefore important, and the electrocardiogram (ECG) is a simple and effective method for achieving this. However, it requires assessment by a specialist; so many recent works have focused on the automatic assessment of ECG signals. METHODS: For the detection and localization of MI, deep learning models have been proposed, but the diagnostic accuracy of this approaches still need to be improved. Moreover, with deep learning methods the way in which a given result was achieved lacks interpretability. In this study, ECG data was obtained from the PhysioBank open access database, and was analyzed as follows. Firstly, the 12-lead ECG signal was preprocessed to identify each beat and obtain each heart interval. Secondly, a multi-scale deep learning model combined with a residual network and attention mechanism was proposed, where the input was the 12-lead ECG recording. Through the SENet model and the Grad-CAM algorithm, the weighting of each lead was calculated and visualized. Using existing knowledge of the way in which different types of MI gave characteristic patterns in specific ECG leads, the model was used to provisionally diagnose the type of MI according to the characteristics of each of the 12 ECG leads. RESULTS: Ten types of MI anterior, anterior lateral, anterior septal, inferior, inferior lateral, inferior posterior, inferior posterior lateral, lateral, posterior, and posterior lateral were diagnosed. The average accuracy, sensitivity, and specificity for MI detection of all lesion types was 99.98, 99.94, and 99.98%, respectively; and the average accuracy, sensitivity, and specificity for MI localization was 99.79, 99.88, and 99.98%, respectively. CONCLUSION: When compared to existing models based on traditional machine learning methods, convolutional neural networks and recurrent neural networks, the results showed that the proposed model had better diagnostic performance, being superior in accuracy, sensitivity, and specificity

    Robust heart-rate estimation from facial videos using Project_ICA.

    Get PDF
    ‘This is an author-created, un-copyedited version of an article published in Physiological Measurement. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/1361-6579/ab2c9f’OBJECTIVE: Remote photoplethysmography (rPPG) can achieve non-contact measurement of heart rate (HR) from a continuous video sequence by scanning the skin surface. However, practical applications are still limited by factors such as non-rigid facial motion and head movement. In this work, a detailed system framework for remotely estimating heart rate from facial videos under various movement conditions is described. APPROACH: After the rPPG signal has been obtained from a defined region of the facial skin, a method, termed 'Project_ICA', based on a skin reflection model, is employed to extract the pulse signal from the original signal. MAIN RESULTS: To evaluate the performance of the proposed algorithm, a dataset containing 112 videos including the challenges of various skin tones, body motion and HR recovery after exercise was created from 28 participants. SIGNIFICANCE: The results show that Project_ICA, when evaluated by several criteria, provides a more accurate and robust estimate of HR than most existing methods, although problems remain in obtaining reliable measurements from dark-skinned subjects

    Statistical Analysis of the Consistency of HRV Analysis Using BCG or Pulse Wave Signals

    Get PDF
    Ballistocardiography (BCG) is considered a good alternative to HRV analysis with its non-contact and unobtrusive acquisition characteristics. However, consensus about its validity has not yet been established. In this study, 50 healthy subjects (26.2 ± 5.5 years old, 22 females, 28 males) were invited. Comprehensive statistical analysis, including Coefficients of Variation (CV), Lin’s Concordance Correlation Coefficient (LCCC), and Bland-Altman analysis (BA ratio), were utilized to analyze the consistency of BCG and ECG signals in HRV analysis. If the methods gave different answers, the worst case was taken as the result. Measures of consistency such as Mean, SDNN, LF gave good agreement (the absolute value of CV difference 0.99, BA ratio 0.95, BA ratio < 0.2), while RMSSD, HF, LF/HF indicated poor agreement (the absolute value of CV difference ≥ 5% or LCCC ≤ 0.95 or BA ratio ≥ 0.2). Additionally, the R-R intervals were compared with P-P intervals extracted from the pulse wave (PW). Except for pNN50, which exhibited poor agreement in this comparison, the performances of the HRV indices estimated from the PW and the BCG signals were similar
    corecore