2,580 research outputs found

    Modifying a Commercial Centrifuge to Reduce Electromagnetic Interference and Evaluating Functionality of Ultrasound Equipment

    Get PDF
    The Project Management and Engineering Branch (SF4) supports the Human Health and Performance Directorate (HH&P) and is responsible for developing and supporting human systems hardware for the International Space Station (ISS). When a principal investigator's (PI) medical research project on the ISS is accepted, SF4 develops the necessary hardware and software to transport to the ISS. The two projects I primarily worked on were the centrifuge and ultrasound projects. Centrifuge: One concern with spacecraft such as the ISS is electromagnetic interference (EMI) from onboard equipment, typically from radio waves (frequencies of ~3 kHz to ~300 GHz), which can negatively affect nearby circuitry. Standard commercial centrifuges produce EMI above safety limits, so my task was to help reduce EMI production from this equipment. Two centrifuges were tested: one unmodified as a control and one modified. To reduce EMI below safety limits, one centrifuge was modified to become a Faraday shield, in which significant electrical contact was made between all regions of the centrifuge housing. This included removing non-conductive paint, applying conductive fabric to the lid and foam sealer, adding a 10,000 F decoupling capacitor across the power supply, and adding copper adhesive-mount gaskets to the housing interior. EMI testing of both centrifuges was performed in the EMI/EMC Control Test and Measurement Facility. EMI for both centrifuges was below safety limits for frequencies between 10 MHz and 15 GHz (pass); however, between 14 kHz and 10 MHz, EMI for the unmodified centrifuge exceeded safety limits (fail) as expected. Alternatively, for the modified centrifuge with the Faraday shield, EMI was below the safely limit of 55 dBV/m for electromagnetic frequencies between 14 kHz and 10 MHz. This result indicates our modifications were successful. The successful EMI test allowed us to communicate with the vendor what modifications they needed to make to their commercial unit to meet our specifications and to understand what needs to be done in lab to the new centrifuge. Our modifications will provide a standard for readying centrifuges for future missions. Once the new modified centrifuge arrives by the vendor, it will need to undergo EMI testing again for validation. The centrifuge is also in the process of compatibility testing with a custom stowage drawer, which is an ongoing project in SF4. Both of these items will be payloads on future missions to the ISS for various research purposes. Ultrasound: ISS currently has an onboard ultrasound (Ultrasound 2 system) for research and medical purposes. Every piece of medical flight hardware has an equivalent ground-unit so instrumentation can be routinely evaluated and transported to the ISS if necessary. The ground-unit ultrasound equipment must be evaluated every six months using a task performance sheet (TPS). A TPS is a document, written by the appropriate scientists and engineers, which describes how to run equipment and is written in such a way that astronauts with unspecialized training can follow the tasks. I was responsible for performing six TPSs on a combination of three ultrasounds and two video power converters (VPCs). Performing a TPS involves checking out and computationally documenting each piece of equipment removed from storage locations, setting up hardware and software, performing tasks to verify functionality, returning equipment, and logging items back into the computerized system. My work revealed all ground-unit ultrasounds were functioning properly. Because of proper function, a discrepancy report (DR) did not have to be opened. The TPS was then passed along to the Quality Engineering (QE) for review and ultimately given to Quality Assurance (QA). Other projects: In addition to my main projects, I participated in other tasks including troubleshooting an EEG headband, volunteering for an ultrasound training research study, and conformal coating printed circuit boards. My internship at SF4 has helped me understand how space systems hardware development for the ISS fits into NASA's mission and vision

    Cumulative luminosity functions of the X-ray point source population in M31

    Full text link
    We present preliminary results from a detailed analysis of the X-ray point sources in the XMM-Newton survey of M31. These sources are expected to be mostly X-ray binaries. We have so far studied 225 of the 535 sources found by automated source detection. Only sources which were present in all three EPIC images were considered. X-ray binaries are identified by their energy spectrum and power density spectrum. Unlike in other surveys we have obtained source luminosities from freely fit emission models. We present uncorrected luminosity functions of the sources analysed so far.Comment: 2 pages, 1 figure. To appear in proceedings of IAUS23

    XMM-Newton reveals ~100 new LMXBs in M31 from variability studies

    Full text link
    We have conducted a survey of X-ray sources in XMM-Newton observations of M31, examining their power density spectra (PDS) and spectral energy distributions (SEDs). Our automated source detection yielded 535 good X-ray sources; to date, we have studied 225 of them. In particular, we examined the PDS because low mass X-ray binaries (LMXBs) exhibit two distinctive types of PDS. At low accretion rates, the PDS is characterised by a broken power law, with the spectral index changing from ~0 to ~1 at some frequency in the range \~0.01--1 Hz; we refer to such PDS as Type A. At higher accretion rates, the PDS is described by a simple power law; we call these PDS Type B. Of the 225 sources studied to date, 75 exhibit Type A variability, and are almost certainly LMXBs, while 6 show Type B but not Type A, and are likely LMXBs. Of these 81 candidate LMXBs, 71 are newly identified in this survey; furthermore, they are mostly found near the centre of M31. Furthermore, most of the X-ray population in the disc are associated with the spiral arms, making them likely high mass X-ray binaries (HMXBs). In general these HMXBs do not exhibit Type A variability, while many central X-ray sources (LMXBs) in the same luminosity range do. Hence the PDS may distinguish between LMXBs and HMXBs in this luminosity range.Comment: 4 pages, 2 figures. To appear in proceedings of IAUS230: "Populations of High Energy Sources in Galaxies", 14-19 August 2005, Dublin, Eds E.J.A. Meurs and G. Fabbian

    Allied Health Accreditation Project

    Get PDF
    No abstract available

    Self-referenced characterization of space-time couplings in near single-cycle laser pulses

    Get PDF
    We report on the characterization of space-time couplings in high energy sub-2-cycle 770nm laser pulses using a self-referencing single-shot method. Using spatially-encoded arrangement filter-based spectral phase interferometry for direct electric field reconstruction (SEA-F-SPIDER) we characterize few-cycle pulses with a wave-front rotation of 2.8x?10^11 rev/sec (1.38 mrad per half-cycle) and pulses with pulse front tilts ranging from to -0.33 fs/um to -3.03 fs/um.Comment: 6 pages, 6 figure

    Comparison of Three Methods for Sampling Fishes and Macroinvertebrates in a Vegetated Wetland

    Get PDF
    Three methods of sampling fishes, two seining methods and a drop trap method, were evaluated in heavily vegetated freshwater habitats. The portable drop trap method, which utilized a 1 x 1 m-sq. trap, collected significantly more macroinvertebrates and fish per unit area than did the seining methods. The meter square drop trap offered the additional advantages of a greater number of animals per unit effort and an integrated sample of vegetation, macroinvertebrates and fish in a given area. A 90% (s.d.= 7.4%) recovery of tagged fishes released into the traps in different habitats showed the m2 drop trap to be a highly reliable and effective sampling method for fish in vegetated wetlands

    Reducing the energy consumption of heavy goods vehicles through the application of lightweight trailers: Fleet case studies

    Get PDF
    Reducing the empty weight of articulated heavy goods vehicle trailers is one avenue that needs to be explored in reducing the carbon footprint of the road freight industry as a whole. A statistical analysis of two heavy goods vehicle fleets operating in the United Kingdom has helped to identify double-deck trailers used in grocery haulage and 'walking-floor' trailers used in bulk haulage as two examples of trailers that can benefit significantly from lightweighting. Energy consumption of numerous articulated heavy goods vehicles is quantified through an idealised drive cycle analysis reflecting a long haul journey over a highway. This energy analysis allows for a mass energy performance index to be established. The analysis has shown that reducing the empty weight of trailers by 30% can cause reductions of up to 18% and 11% in mass energy performance index for double-deck trailers and 'walking-floor' trailers respectively. Using this approach, trailers that will benefit the most from weight reduction can be identified systematically, allowing for lightweighting strategies to be implemented more effectively. Strategies to reduce empty trailer weight and improve vehicle utilisation are also discussedThe authors would like to acknowledge the financial support from the members of the Centre for Sustainable Road Freight and from the Engineering and Physical Sciences Research Council (Grant Reference EP/K00915X/1).This is the final version of the article. It first appeared from Elsevier via http://dx.doi.org/10.1016/j.trd.2015.09.01

    Rehabilitation in chronic respiratory diseases: In-hospital and post-exacerbation pulmonary rehabilitation: Peri-exacerbation pulmonary rehabilitation

    Get PDF
    Exacerbations of chronic obstructive pulmonary disease (COPD) that require hospitalization are important events for patients. Functional impairment and skeletal muscle dysfunction can increase the risk of hospitalization and readmission, independent of lung function. In addition, once a patient is admitted, multiple factors can lead to worsening outcome including immobility, systemic inflammation and nutritional depletion. These non‐pulmonary factors are potentially amenable to exercise therapy, as part of pulmonary rehabilitation (PR). Peri‐exacerbation PR has an important role in the management of exacerbations of COPD. In this review, we explore how functional limitation and skeletal muscle dysfunction affect patients having a severe exacerbation of COPD, the systemic impact of hospitalization on patients including potential aetiologies and the role of PR around the time of an exacerbation. This includes rehabilitation during the inpatient phase, post‐exacerbation rehabilitation and rehabilitation bridging hospital discharge. We also describe potential future developments in peri‐exacerbation PR

    Evaporative CO2 cooling using microchannels etched in silicon for the future LHCb vertex detector

    Full text link
    The extreme radiation dose received by vertex detectors at the Large Hadron Collider dictates stringent requirements on their cooling systems. To be robust against radiation damage, sensors should be maintained below -20 degree C and at the same time, the considerable heat load generated in the readout chips and the sensors must be removed. Evaporative CO2 cooling using microchannels etched in a silicon plane in thermal contact with the readout chips is an attractive option. In this paper, we present the first results of microchannel prototypes with circulating, two-phase CO2 and compare them to simulations. We also discuss a practical design of upgraded VELO detector for the LHCb experiment employing this approach.Comment: 12 page
    corecore