39,466 research outputs found
Ablation of carbonaceous materials in a hydrogen-helium arc-jet flow
The stagnation-point ablation rates of a graphite, a carbon-carbon composite, and four carbon-phenolic materials are measured in an arc-jet wind tunnel with a 50% hydrogen-50% helium mixture as the test gas. Flow environments are determined through measurements of static and impact pressures, heat-transfer rates to a calorimeter, and radiation spectra, and through numerical calculation of the flow through the wind tunnel, spectra, and heat-transfer rates. The environments so determined are: impact pressure approx. 3 atm, Mach number approx. 2.1, convective heat-transfer rate approx. 14 kw/sq cm, and radiative heat-transfer rate approx. 7 kw/sq cm in the absence of ablation. Ablation rates are determined from the measured rates of mass loss and recession of the ablation specimens. Compared with the predicted ablation rates obtained by running RASLE and CMA codes, the measured rates are higher by about 15% for all tested materials
Measuring Active-Sterile Neutrino Oscillations with a Stopped Pion Neutrino Source
The question of the existence of light sterile neutrinos is of great interest
in many areas of particle physics, astrophysics, and cosmology. Furthermore,
should the MiniBooNE experiment at Fermilab confirm the LSND oscillation
signal, then new measurements are required to identify the mechanism
responsible for these oscillations. Possibilities include sterile neutrinos, CP
or CPT violation, variable mass neutrinos, Lorentz violation, and extra
dimensions. In this paper, we consider an experiment at a stopped pion neutrino
source to determine if active-sterile neutrino oscillations with delta-m
greater than 0.1 eV2 can account for the signal. By exploiting stopped pi+
decay to produce a monoenergetic nu_mu source, and measuring the rate of the
neutral current reaction nu_x + 12C -> nu_x +12C* as a function of distance
from the source, we show that a convincing test for active-sterile neutrino
oscillations can be performed.Comment: 10 pages, 9 figure
Material Properties Measurements for Selected Materials
Hugoniot equation of state measurements were made on Coconino sandstone, Vacaville basalt, Kaibab limestone, Mono Crater, pumice and Zelux (a polycarbonate resin) for pressures to 2 Mb. A single data point was obtained for fused quartz at 1.6 Mb. In addition to the hugoniot studies, the uniaxial compressive stress behavior of Vacaville basalt and Zelux was investigated at strain rates from about 10(exp -5)/sec to 10(exp 3)/second. The data presented include the stress - strain relations as a function of strain rate for these two materials
Recommended from our members
14C-Cobalamin Absorption from Endogenously Labeled Chicken Eggs Assessed in Humans Using Accelerator Mass Spectrometry.
Traditionally, the bioavailability of vitamin B-12 (B12) from in vivo labeled foods was determined by labeling the vitamin with radiocobalt (57Co, 58Co or 60Co). This required use of penetrating radioactivity and sometimes used higher doses of B12 than the physiological limit of B12 absorption. The aim of this study was to determine the bioavailability and absorbed B12 from chicken eggs endogenously labeled with 14C-B12 using accelerator mass spectrometry (AMS). 14C-B12 was injected intramuscularly into hens to produce eggs enriched in vivo with the 14C labeled vitamin. The eggs, which provided 1.4 to 2.6 μg of B12 (~1.1 kBq) per serving, were scrambled, cooked and fed to 10 human volunteers. Baseline and post-ingestion blood, urine and stool samples were collected over a one-week period and assessed for 14C-B12 content using AMS. Bioavailability ranged from 13.2 to 57.7% (mean 30.2 ± 16.4%). Difference among subjects was explained by dose of B12, with percent bioavailability from 2.6 μg only half that from 1.4 μg. The total amount of B12 absorbed was limited to 0.5-0.8 μg (mean 0.55 ± 0.19 μg B12) and was relatively unaffected by the amount consumed. The use of 14C-B12 offers the only currently available method for quantifying B12 absorption in humans, including food cobalamin absorption. An egg is confirmed as a good source of B12, supplying approximately 20% of the average adult daily requirement (RDA for adults = 2.4 μg/day)
Development and analysis of the Software Implemented Fault-Tolerance (SIFT) computer
SIFT (Software Implemented Fault Tolerance) is an experimental, fault-tolerant computer system designed to meet the extreme reliability requirements for safety-critical functions in advanced aircraft. Errors are masked by performing a majority voting operation over the results of identical computations, and faulty processors are removed from service by reassigning computations to the nonfaulty processors. This scheme has been implemented in a special architecture using a set of standard Bendix BDX930 processors, augmented by a special asynchronous-broadcast communication interface that provides direct, processor to processor communication among all processors. Fault isolation is accomplished in hardware; all other fault-tolerance functions, together with scheduling and synchronization are implemented exclusively by executive system software. The system reliability is predicted by a Markov model. Mathematical consistency of the system software with respect to the reliability model has been partially verified, using recently developed tools for machine-aided proof of program correctness
Green-Schwarz Formulation of Self-Dual Superstring
The self-dual superstring has been described previously in a
Neveu-Schwarz-Ramond formulation with local N=2 or 4 world-sheet supersymmetry.
We present a Green-Schwarz-type formulation, with manifest spacetime
supersymmetry.Comment: 11 pg., (uuencoded dvi file) ITP-SB-92-5
OH Zeeman Magnetic Field Detections Toward Five Supernova Remnants Using the VLA
We have observed the OH (1720 MHz) line in five galactic SNRs with the VLA to
measure their magnetic field strengths using the Zeeman effect. We detected all
12 of the bright ( mJy) OH (1720 MHz) masers previously detected
by Frail et al. (1996) and Green et al. (1997) and measured significant
magnetic fields (i.e. ) in ten of them. Assuming that the
``thermal'' Zeeman equation can be used to estimate for OH
masers, our estimated fields range from 0.2 to 2 mG. These magnetic field
strengths are consistent with the hypothesis that ambient molecular cloud
magnetic fields are compressed via the SNR shock to the observed values.
Magnetic fields of this magnitude exert a considerable influence on the
properties of the cloud with the magnetic pressures ( erg
cm) exceeding the pressure in the ISM or even the thermal pressure of
the hot gas interior to the remnant. This study brings the number of galactic
SNRs with OH (1720 MHz) Zeeman detections to ten.Comment: 23 pages, 14 figures, accepted to ApJ, for higher resolution images
of Figs 4,11, and 12 see http://www.pa.uky.edu/~brogan/brog_publ.htm
Temporal variability and statistics of the Strehl ratio in adaptive-optics images
We have investigated the temporal variability and statistics of the
"instantaneous" Strehl ratio. The observations were carried out with the 3.63-m
AEOS telescope equipped with a high-order adaptive optics system. In this paper
Strehl ratio is defined as the peak intensity of a single short exposure. We
have also studied the behaviour of the phase variance computed on the
reconstructed wavefronts. We tested the Marechal approximation and used it to
explain the observed negative skewness of the Strehl ratio distribution. The
estimate of the phase variance is shown to fit a three-parameter Gamma
distribution model. We show that simple scaling of the reconstructed wavefronts
has a large impact on the shape of the Strehl ratio distribution.Comment: submitted to PAS
Influence of cold-water immersion on limb blood flow after resistance exercise.
This study determined the influence of cold (8°C) and cool (22°C) water immersion on lower limb and cutaneous blood flow following resistance exercise. Twelve males completed 4 sets of 10-repetition maximum squat exercise and were then immersed, semi-reclined, into 8°C or 22°C water for 10-min, or rested in a seated position (control) in a randomized order on different days. Rectal and thigh skin temperature, muscle temperature, thigh and calf skin blood flow and superficial femoral artery blood flow were measured before and after immersion. Indices of vascular conductance were calculated (flux and blood flow/mean arterial pressure). The colder water reduced thigh skin temperature and deep muscle temperature to the greatest extent (P < .001). Reductions in rectal temperature were similar (0.2-0.4°C) in all three trials (P = .69). Femoral artery conductance was similar after immersion in both cooling conditions, with both conditions significantly lower (55%) than the control post-immersion (P < .01). Similarly, there was greater thigh and calf cutaneous vasoconstriction (40-50%) after immersion in both cooling conditions, relative to the control (P < .01), with no difference between cooling conditions. These findings suggest that cold and cool water similarly reduce femoral artery and cutaneous blood flow responses but not muscle temperature following resistance exercise
- …