462 research outputs found

    Operational Experience and Characterization of a Superconducting Transverse Gradient Undulator for Compact Laser Wakefield Accelerator-Driven FEL

    Get PDF
    A 40-period superconducting transverse gradient undulator (TGU) has been designed and fabricated at Karlsruhe Institute of Technology (KIT). Combining a TGU with a Laser Wakefield Accelerator (LWFA) is a potential key for realizing an extremely compact Free Electron Laser (FEL) radiation source. The TGU scheme is a viable option to compensate the challenging properties of the LWFA electron beam in terms of beam divergence and energy spread. In this contribution, we report on the operational experience of this TGU inside its own cryostat and show the current status of the TGU and the further plan for experiments

    Beam heat load and pressure rise in a cold vacuum chamber

    Get PDF
    The beam heat load and the pressure in the vacuum chamber of the cold bore superconducting undulator installed at ANKA (ANgstrom source KArlsruhe) have been monitored for almost two years. Possible sources of the observed heat load could be synchrotron radiation from upstream magnets, image currents, electron and ion bombardment. In this paper, the various possible contributions to the heat load are discussed and compared with experimental results. The dynamic pressure increases nonlinearly with the average beam current. The current where it assumes a maximum varies both with the bunch intensity and with the initial vacuum pressure. A correlation between the heat load and the dynamic pressure has been observed. This study suggests that electron bombardment could explain the beam heat load and pressure rise observed for a bunch length of 10 mm

    Beam heat load and pressure rise in a could vacuum chamber

    Get PDF
    The beam heat load and the pressure in the vacuum chamber of the cold bore superconducting undulator installed at ANKA (ANgstrom source KArlsruhe) have been monitored for almost two years. Possible sources of the observed heat load could be synchrotron radiation from upstream magnets, image currents, electron and ion bombardment. In this paper, the various possible contributions to the heat load are discussed and compared with experimental results. The dynamic pressure increases nonlinearly with the average beam current. The current where it assumes a maximum varies both with the bunch intensity and with the initial vacuum pressure. A correlation between the heat load and the dynamic pressure has been observed. This study suggests that electron bombardment could explain the beam heat load and pressure rise observed for a bunch length of 10 mm

    Magnetic Characterization of a Superconducting Transverse Gradient Undulator for Compact Laser Wakefield Accelerator-Driven FELs

    Get PDF
    A transverse gradient undulator (TGU) is a key component compensating for the relatively large energy spread of Laser Wakefield Accelerator (LWFA)-generated electron beams for realizing a compact Free Electron Laser (FEL). A superconducting TGU with 40 periods has been fabricated at the Karlsruhe Institute of Technology (KIT). In this contribution, we report that the superconducting TGU has been commissioned with nominal operational parameters at an off-line test bench. An experimental set-up for mapping the magnetic field on a two-dimensional grid in the TGU gap has been employed for the magnetic characterization. We show the first preliminary results of these measurements showing the longitudinal quality, the transverse gradient and the transient behaviour of the superconducting TGU field

    Parasite-Derived Plasma Microparticles Contribute Significantly to Malaria Infection-Induced Inflammation through Potent Macrophage Stimulation

    Get PDF
    There is considerable debate as to the nature of the primary parasite-derived moieties that activate innate pro-inflammatory responses during malaria infection. Microparticles (MPs), which are produced by numerous cell types following vesiculation of the cellular membrane as a consequence of cell death or immune-activation, exert strong pro-inflammatory activity in other disease states. Here we demonstrate that MPs, derived from the plasma of malaria infected mice, but not naive mice, induce potent activation of macrophages in vitro as measured by CD40 up-regulation and TNF production. In vitro, these MPs induced significantly higher levels of macrophage activation than intact infected red blood cells. Immunofluorescence staining revealed that MPs contained significant amounts of parasite material indicating that they are derived primarily from infected red blood cells rather than platelets or endothelial cells. MP driven macrophage activation was completely abolished in the absence of MyD88 and TLR-4 signalling. Similar levels of immunogenic MPs were produced in WT and in TNF−/−, IFN-γ−/−, IL-12−/− and RAG-1−/− malaria-infected mice, but were not produced in mice injected with LPS, showing that inflammation is not required for the production of MPs during malaria infection. This study therefore establishes parasitized red blood cell-derived MPs as a major inducer of systemic inflammation during malaria infection, raising important questions about their role in severe disease and in the generation of adaptive immune responses

    Investigations on NbTi superconducting racetrack coils under pulsed-current excitations

    Get PDF
    One of the key issues in the technology of superconductors is the protection against quenches. When designing a superconductor as a magnet, a coil or even current leads, the design should be made such that the superconductor withstands all operational conditions as fast discharges, pulsed loads or even rapid transient background fields. Computational modeling of pulsed-current characterization in a self-field NbTi racetrack sample coil has been performed using the finite element modelling software Opera as a step towards understanding the thermal and electromagnetic processes during a quench. The pulse was modelled to be generated by discharging a capacitor into an RLC circuit, which includes the NbTi racetrack coil as the sample under test. The coil was driven to the resistive state and the quench occurred by applying the pulse with a peak value exceeding the critical current of the sample coil. This contribution presents the results obtained from investigating a pulsed NbTi coil in a model based on an electromagnetic analysis. In addition, a comparison to the theoretical expectations derived for the damped oscillations in the pulse-driving circuit is given. Finally, the results from a coupled analysis, where both thermal and electromagnetic properties are being considered, within a quench multi-physics study are presented

    Home parenteral nutrition with an omega-3-fatty-acid-enriched MCT/LCT lipid emulsion in patients with chronic intestinal failure (the HOME study):study protocol for a randomized, controlled, multicenter, international clinical trial

    Get PDF
    BACKGROUND: Home parenteral nutrition (HPN) is a life-preserving therapy for patients with chronic intestinal failure (CIF) indicated for patients who cannot achieve their nutritional requirements by enteral intake. Intravenously administered lipid emulsions (ILEs) are an essential component of HPN, providing energy and essential fatty acids, but can become a risk factor for intestinal-failure-associated liver disease (IFALD). In HPN patients, major effort is taken in the prevention of IFALD. Novel ILEs containing a proportion of omega-3 polyunsaturated fatty acids (n-3 PUFA) could be of benefit, but the data on the use of n-3 PUFA in HPN patients are still limited. METHODS/DESIGN: The HOME study is a prospective, randomized, controlled, double-blind, multicenter, international clinical trial conducted in European hospitals that treat HPN patients. A total of 160 patients (80 per group) will be randomly assigned to receive the n-3 PUFA-enriched medium/long-chain triglyceride (MCT/LCT) ILE (Lipidem/Lipoplus® 200 mg/ml, B. Braun Melsungen AG) or the MCT/LCT ILE (Lipofundin® MCT/LCT/Medialipide® 20%, B. Braun Melsungen AG) for a projected period of 8 weeks. The primary endpoint is the combined change of liver function parameters (total bilirubin, aspartate transaminase and alanine transaminase) from baseline to final visit. Secondary objectives are the further evaluation of the safety and tolerability as well as the efficacy of the ILEs. DISCUSSION: Currently, there are only very few randomized controlled trials (RCTs) investigating the use of ILEs in HPN, and there are very few data at all on the use of n-3 PUFAs. The working hypothesis is that n-3 PUFA-enriched ILE is safe and well-tolerated especially with regard to liver function in patients requiring HPN. The expected outcome is to provide reliable data to support this thesis thanks to a considerable number of CIF patients, consequently to broaden the present evidence on the use of ILEs in HPN. TRIAL REGISTRATION: ClinicalTrials.gov, ID: NCT03282955. Registered on 14 September 2017

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration
    • …
    corecore