17 research outputs found
Recommended from our members
The Promises and Pitfalls of Genoeconomics
This article reviews existing research at the intersection of genetics and economics, presents some new findings that illustrate the state of genoeconomics research, and surveys the prospects of this emerging field. Twin studies suggest that economic outcomes and preferences, once corrected for measurement error, appear to be about as heritable as many medical conditions and personality traits. Consistent with this pattern, we present new evidence on the heritability of permanent income and wealth. Turning to genetic association studies, we survey the main ways that the direct measurement of genetic variation across individuals is likely to contribute to economics, and we outline the challenges that have slowed progress in making these contributions. The most urgent problem facing researchers in this field is that most existing efforts to find associations between genetic variation and economic behavior are based on samples that are too small to ensure adequate statistical power. This has led to many false positives in the literature. We suggest a number of possible strategies to improve and remedy this problem: (a) pooling data sets, (b) using statistical techniques that exploit the greater information content of many genes jointly, and (c) focusing on economically relevant traits that are most proximate to known biological mechanisms.EconomicsSociolog
European survey on preanalytical sample handling - Part 1: How do European laboratories monitor the preanalytical phase? On behalf of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE)
Introduction: Compared to other activities of the testing process, the preanalytical phase is plagued by a lower degree of standardization, which makes it more vulnerable to errors. With the aim of providing guidelines and recommendations, the EFLM WG-PRE issued a survey across European medical laboratories, to gather information on local preanalytical practices. This is part one of two coherent articles, which covers all practices on monitoring preanalytical quality except haemolysis, icterus and lipemia (HIL). Materials and methods: An online survey, containing 39 questions dealing with a broad spectrum of preanalytical issues, was disseminated to EFLM member countries. The survey included questions on willingness of laboratories to engage in preanalytical issues. Results: Overall, 1405 valid responses were received from 37 countries. 1265 (94%) responders declared to monitor preanalytical errors. Assessment, documentation and further use of this information varied widely among respondents and partially among countries. Many responders were interested in a preanalytical online platform, holding information on various aspects of the preanalytical phase (N = 1177; 87%), in a guideline for measurement and evaluation of preanalytical variables (N = 1235; 92%), and in preanalytical e-learning programs or webinars (N = 1125; 84%). Fewer responders were interested in, or already participating in, preanalytical EQA programs (N = 951; 71%). Conclusion: Although substantial heterogeneity was found across European laboratories on preanalytical phase monitoring, the interest in preanalytical issues was high. A large majority of participants indicated an interest in new guidelines regarding preanalytical variables and learning activities. This important data will be used by the WG-PRE for providing recommendations on the most critical issues.status: publishe
European survey on preanalytical sample handling - Part 2: Practices of European laboratories on monitoring and processing haemolytic, icteric and lipemic samples. On behalf of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE)
Introduction: No guideline currently exists on how to detect or document haemolysis, icterus or lipemia (HIL) in blood samples, nor on subsequent use of this information. The EFLM WG-PRE has performed a survey for assessing current practices of European laboratories in HIL monitoring. This second part of two coherent articles is focused on HIL. Materials and methods: An online survey, containing 39 questions on preanalytical issues, was disseminated among EFLM member countries. Seventeen questions exclusively focused on assessment, management and follow-up actions of HIL in routine blood samples. Results: Overall, 1405 valid responses from 37 countries were received. A total of 1160 (86%) of all responders stating to analyse blood samples - monitored HIL. HIL was mostly checked in clinical chemistry samples and less frequently in those received for coagulation, therapeutic drug monitoring and serology/infectious disease testing. HIL detection by automatic HIL indices or visual inspection, along with haemolysis cut-offs definition, varied widely among responders. A quarter of responders performing automated HIL checks used internal quality controls. In haemolytic/icteric/lipemic samples, most responders (70%) only rejected HIL-sensitive parameters, whilst about 20% released all test results with general comments. Other responders did not analysed but rejected the entire sample, while some released all tests, without comments. Overall, 26% responders who monitored HIL were using this information for monitoring phlebotomy or sample transport quality. Conclusion: Strategies for monitoring and treating haemolytic, icteric or lipemic samples are quite heterogeneous in Europe. The WG-PRE will use these insights for developing and providing recommendations aimed at harmonizing strategies across Europe.status: publishe
European survey on preanalytical sample handling - Part 1 : How do European laboratories monitor the preanalytical phase? On behalf of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE)
Introduction: Compared to other activities of the testing process, the preanalytical phase is plagued by a lower degree of standardization, which makes it more vulnerable to errors. With the aim of providing guidelines and recommendations, the EFLM WG-PRE issued a survey across European medical laboratories, to gather information on local preanalytical practices. This is part one of two coherent articles, which covers all practices on monitoring preanalytical quality except haemolysis, icterus and lipemia (HIL). Materials and methods: An online survey, containing 39 questions dealing with a broad spectrum of preanalytical issues, was disseminated to EFLM member countries. The survey included questions on willingness of laboratories to engage in preanalytical issues. Results: Overall, 1405 valid responses were received from 37 countries. 1265 (94%) responders declared to monitor preanalytical errors. Assessment, documentation and further use of this information varied widely among respondents and partially among countries. Many responders were interested in a preanalytical online platform, holding information on various aspects of the preanalytical phase (N = 1177; 87%), in a guideline for measurement and evaluation of preanalytical variables (N = 1235; 92%), and in preanalytical e-learning programs or webinars (N = 1125; 84%). Fewer responders were interested in, or already participating in, preanalytical EQA programs (N = 951; 71%). Conclusion: Although substantial heterogeneity was found across European laboratories on preanalytical phase monitoring, the interest in preanalytical issues was high. A large majority of participants indicated an interest in new guidelines regarding preanalytical variables and learning activities. This important data will be used by the WG-PRE for providing recommendations on the most critical issues
European survey on preanalytical sample handling - Part 2 : Practices of European laboratories on monitoring and processing haemolytic, icteric and lipemic samples. On behalf of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE)
Introduction: No guideline currently exists on how to detect or document haemolysis, icterus or lipemia (HIL) in blood samples, nor on subsequent use of this information. The EFLM WG-PRE has performed a survey for assessing current practices of European laboratories in HIL monitoring. This second part of two coherent articles is focused on HIL. Materials and methods: An online survey, containing 39 questions on preanalytical issues, was disseminated among EFLM member countries. Seventeen questions exclusively focused on assessment, management and follow-up actions of HIL in routine blood samples. Results: Overall, 1405 valid responses from 37 countries were received. A total of 1160 (86%) of all responders stating to analyse blood samples - monitored HIL. HIL was mostly checked in clinical chemistry samples and less frequently in those received for coagulation, therapeutic drug monitoring and serology/infectious disease testing. HIL detection by automatic HIL indices or visual inspection, along with haemolysis cut-offs definition, varied widely among responders. A quarter of responders performing automated HIL checks used internal quality controls. In haemolytic/icteric/lipemic samples, most responders (70%) only rejected HIL-sensitive parameters, whilst about 20% released all test results with general comments. Other responders did not analysed but rejected the entire sample, while some released all tests, without comments. Overall, 26% responders who monitored HIL were using this information for monitoring phlebotomy or sample transport quality. Conclusion: Strategies for monitoring and treating haemolytic, icteric or lipemic samples are quite heterogeneous in Europe. The WG-PRE will use these insights for developing and providing recommendations aimed at harmonizing strategies across Europe
European survey on preanalytical sample handling – Part 1: How do European laboratories monitor the preanalytical phase? On behalf of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE)
Gene Transfer of Manganese Superoxide Dismutase Extends Islet Graft Function in a Mouse Model of Autoimmune Diabetes
Raccomandazione congiunta EFLM-COLABIOCLI per il prelievo di sangue venoso : [Joint EFLM-COLABIOCLI recommendation for venous blood sampling]
This document provides a joint recommendation for venous blood sampling of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE) and Latin American Working Group for Preanalytical Phase (WG-PRE-LATAM) of the Latin America Confederation of Clinical Biochemistry (COLABIOCLI). It offers guidance on the requirements for ensuring that blood collection is a safe and patient-centered procedure and provides practical guidance on how to successfully overcome potential barriers and obstacles to its widespread implementation. The target audience for this recommendation are healthcare staff members directly involved in blood collection. This recommendation applies to the use of a closed blood collection system and does not provide guidance for the blood collection with an open needle and syringe and catheter collections. Moreover, this document neither addresses patient consent, test ordering, sample handling and transport nor collection from children and unconscious patients. The recommended procedure is based on the best available evidence. Each step was graded using a system that scores the quality of the evidence and the strength of the recommendation. The process of grading was done at several face-to-face meetings involving the same mixture of stakeholders stated previously. The main parts of this recommendation are: 1) Pre-sampling procedures, 2) Sampling procedure, 3) Postsampling procedures and 4) Implementation. A first draft of the recommendation was circulated to EFLM members for public consultation. WG-PRE-LATAM was also invited to comment the document. A revised version has been sent for voting on to all EFLM and COLABIOCLI members and has been officially endorsed by 33/40 EFLM and 21/21 COLABIOCLI members. We encourage professionals throughout Europe and Latin America to adopt and implement this recommendation to improve the quality of blood collection practices and increase patient and workers safety