686 research outputs found

    Academic integrity at ICM: Successes, challenges and opportunities

    Get PDF
    At International College of Manitoba (ICM), we recognized that the stress to students and instructors caused by COVID-19 presented a unique opportunity to raise the awareness of academic integrity in fully online learning. In this presentation we describe several strategies which we employed to mitigate an expected rise in academic misconduct allegations. Strategies were chosen based on reportage from academic literature. Using data collected over two full terms of online learning, we provide insights into emerging trends related to academic integrity and offer a summary of future work in order to improve our performance. We welcome constructive commentary from the audience during question time

    Effect of Different Adhesive Strategies on Bond Quality of Fiber Posts Cemented in Endodontically Treated Teeth

    Get PDF
    Introduction: The purpose of this in vitro study was to assess the effects of anatomic root levels, different adhesive strategies and cementation system on bond strength (BS), nano leakage (NL) and degree of conversion (DC) after fiber posts cementation. Methods and Materials: Sixty-six roots of human premolars were endodontically prepared and divided according to the combination of adhesive application technique (manual passive, manual active and active vibratory) and the cementation system (Adper Single Bond 2/RelyX ARC [SBAR] and Single Bond Universal/RelyX Ultimate [SBUL]). Specimens were transversally sectioned into six 1-mm-thick serial slices, which were subjected to BS testing (n=7), to NL analysis using scanning electron microscopy (SEM) after slice immersion in silver nitrate (n=2), and micro-Raman spectroscopy for DC (n=2). Data were analyzed using two-way ANOVA and Bonferroni post-hoc test (α=5%). Results: Bond strength values significantly increased with active vibratory application technique (P<0.001), no significant difference was noted between adhesive systems. The cementation system Single Bond Universal/RelyX Ultimate demonstrated the lowest nano leakage values (P<0.05). The manual active and vibratory application techniques showed statistically higher degree of conversion values than the manual passive technique at the coronal and medium thirds (P<0.05); and the lowest results were observed with manual passive application to Single Bond Universal/RelyX Ultimate (P=0.016). Conclusion: The study concluded that techniques with active application (vibratory and manual) resulted in higher bond strength values. The mode of adhesive application influence the results.Keywords: Bond Strength; Dental Adhesive; Fiber post; Scanning Electron Microscop

    ANÁLISE COMPARATIVA DA RADIODENSIDADE DE CIMENTOS RESINOSOS UTILIZANDO UM SISTEMA DE RADIOGRAFIA DIGITAL

    Get PDF
    Os cimentos resinosos são materiais utilizados para cimentação de próteses parciais fixas e pinos intra-radiculares, sendo sua radiodensidade fundamental para detecção de excessos proximais e para acompanhamento longitudinal da presença de cárie recorrente. Avaliou-se a radiodensidade de três cimentos resinosos: GI-CEMENT POST-ÂNGELUS® (quimicamente ativado), GII-RelyX ARC-3MESP (polimerização dual) e GIII-Variolink II-Ivoclar/Vivadent (fotoativado). Confeccionou-se 5 corpos-de-prova para cada grupo, padronizados com o auxílio de uma matriz de teflon (8 mm de diâmetro e 2 mm de espessura). Foi empregado o Sistema Intra-oral de Raio-x Digital (GNATUS) e o software Cygnus Imaging® para as tomadas radiográficas. Após a captura da imagem a radiodensidade foi avaliada por um sistema digital de imagens, determinando níveis de cinza, mensurados com o software Image Tool®. O resultado foi obtido por mensuração de pixels contidos nas imagens. Os valores médios e o desvio padrão em porcentagens (%) de branco e preto encontrados para o GI- 48,94% e 51,06% ±3,16, GII- 60,22% e 39,78% ±3,86 e  GIII- 69,36% e 30,64% ±5,32. Concluiu-se que o GIII apresentou maior radiodensidade que os GII e o GI; e que a avaliação da radiopacidade pelo sistema digital é uma alternativa rápida, segura e de fácil execução

    MICRODUREZA DE UMA RESINA COMPOSTA, COR INCISAL, POLIMERIZADA COM DIFERENTES FONTES DE LUZ

    Get PDF
    Fontes de luz à base de LEDs têm sido lançadas no mercado odontológico. Avaliou-se a microdureza de uma resina composta (Filtek Supreme-3MESPE/corYTincisal) utilizando diferentes fontes de luz, sendo:GIOptilux401/Demetron(Halógena-grupo controle); GIIL.E.DemetronI/Demetron (LEDs) e GIIIEliparFreeLight/3MESPE (LEDs). Confeccionou-se cinco corpos-de-prova(CP) para cada grupo, em matrizes metálicas com 2mm de espessura e 5mm de diâmetro. A resina composta foi fotoativada por 40segundos. Os CP foram armazenados à seco e na ausência de luz por 24horas. Em seguida, foi avaliada a microdureza l (Vickers) nas superfícies topo e base, através do microdurômetro digital HMV-2(Shimadzu) com carga de 50gf, durante 30s. Os dados foram submetidos a Análise de Variância para dois critérios e Teste t Student. Os valores médios em HV apresentados na superfície topo por grupo foram: GI(69,76±1,59); GII(68,95±1,45) e GIII(67,87±0,80), diferenças não significativas (p=0,119ANOVA) e, para a superfície base os valores médios foram: GI(62,73±1,57); GII(62,21±0,65) e GIII(61,06±0,87), diferenças não significativas (p=0,086ANOVA). Diferenças significativas ocorreram em todos os grupos entre as superfícies topo e as superfícies base (

    Effect of Root Canal Sealers on Bond Strength of Fiber Posts to Root Dentin Cemented after one Week or six Months

    Get PDF
    Eugenol-based root canal sealers (RCS) have been widely used by clinicians; however, their effect on resinous materials is still questionable. The objective of this study was to evaluate the influence of RCS at 1 week and 6 months’ post obturation on the bond strength (BS) of glass fiber posts (GFP) to root dentin, using conventional and self-adhesive cementation systems (CS). The roots of 56 extracted human canines, were divided in eight groups (n=7) according to the combination of the following factors: RCS (with or without eugenol-Endofill and Sealer 26, respectively), storage period post obturation and prior GFP cementation (1 week and 6 months) and cementation systems (Variolink II - conventional resin cement or RelyX U200-self-adhesive resin cement). After one week, the specimens were transversely sectioned into six 1-mm-thick disks and were subjected to the push out BS test. The data were subjected to 3-way ANOVA and Tukey’s tests (α=0.05). The BS were not affected by the RCS, neither the CS (P>0.05). Just the period post obturation showed statistically significant differences (P£0.05), where the GFP cemented 6 months after the endodontic treatment showed higher values than those cemented 1 week after it. Keywords: Cementation; Dentin; Push-out Bond Strength; Resin Cements; Zinc Oxide Eugenol Cemen

    Avaliação do grau de incapacidade em hanseníase: uma estratégia para sensibilização e capacitação da equipe de enfermagem

    Get PDF
    The main problems caused by leprosy are physical incapacities. This study evaluated the level of patients' incapacity in treatment and in discharge in 11 municipal districts of the14th Regional of Health of Paraná, at the same time it promoted discussion and qualified nursing professionals of local teams. It was verified that 79.8% of the population evaluated presented some degree of incapacity and that some of the professionals ignored the evaluation technique. The percentage of patients with incapacity levels I and II was high, fact that corroborates the late diagnosis of cases. The need of a permanent self-care process associated to polichemotherapy and continuous evaluation of new and old cases in order to avoid the illness physical incapacities is highlighted.Los principales problemas originados de la lepra son las inhabilidades. El actual estudio evaluó el grado de incapacidad de los pacientes en tratamiento y los que ya habían sido curados en 11 ciudades de la 14ª Regional de la Salud de Paraná, Brasil. Al mismo tiempo, promovió discusión y capacitación de los profesionales de enfermería de los equipos locales. Fue verificado que el 79,8% de la población evaluada presentó cierto grado de incapacidad y que los profesionales no conocían la técnica de evaluación. Era alto el porcentaje de pacientes con grado de incapacidad I e II, hecho que comprueba la diagnosis retrasada de los casos. Se destaca la necesidad de un proceso permanente de autocuidado, asociado a la poliquimioterapia y la evaluación continua de los casos nuevos y viejos para prevenir las inhabilidades consiguientes de la enfermedad.Os principais problemas decorrentes da hanseníase são as incapacidades físicas. O presente estudo avaliou o grau de incapacidade dos pacientes em tratamento e em alta, em 11 municípios da 14ª Regional de Saúde do Paraná, ao mesmo tempo em que promoveu discussão e capacitou os profissionais de enfermagem das equipes locais. Verificou-se que 79,8% da população avaliada apresentava algum grau de incapacidade e que parte dos profissionais desconhecia a técnica de avaliação. Foi grande a porcentagem de pacientes com grau de incapacidade I e II, fato que corrobora o diagnóstico tardio dos casos. Destaca-se a necessidade de permanente processo de autocuidado, associado à poliquimioterapia e avaliação contínua dos casos novos e antigos para evitar as incapacidades físicas conseqüentes do agravo

    EFEITO DE SISTEMAS DE FOTOATIVAÇÃO NA FORMAÇÃO DE MICROFENDAS MARGINAIS EM RESTAURAÇÕES CLASSE II

    Get PDF
    O objetivo deste estudo foi avaliar a formação de fendas em restaurações de resina composta classe II, utilizando um aparelho à base de lâmpada halógena (QTH), e dois fotopolimerizadores por diodo (LED). Cavidades padronizadas foram executadas nas faces proximais de 18 terceiros molares humanos. Resina composta Filtek P60 (3MESPE) foi inserida por meio de uma ponta fotocondensadora e fotoativada usando três sistemas de fotoativação: GI-Optilux401(QTH); GII-ColtoluxLED (LED) e GIII-UltraLumeLED5 (LED). Após o acabamento os dentes foram submetidos à ciclagem térmica à 5oC+2oC e 55oC+2oC, realizando um total de 500 ciclos. Os dentes foram seccionados no sentido vestíbulo-lingual e depois no centro das restaurações. A extensão da fenda foi observada sob MEV com um aumento de 1000X. Os dados foram analisados através do teste não paramétrico de Kruskal-Wallis. Os valores médios da amplitude das microfendas foram: GI 3,28+3,34 mm; GII 1,48+1,89 mm e GIII 3,11+3,45 mm. Concluiu-se que fendas marginais foram observadas em todos os grupos; e entre os aparelhos de fotoativação utilizados neste estudo não houve diferenças estatísticas significantes, apesar de uma tendência de melhor desempenho para o GII

    ADAPTAÇÃO MARGINAL DE UMA RESINA COMPOSTA: EFEITO DE SISTEMAS DE FOTOATIVAÇÃO

    Get PDF
    A contração de polimerização é o maior problema na adaptação marginal das restaurações em resina composta fotopolimerizável, causando a formação de fendas marginais. O objetivo foi avaliar a formação destas fendas em restaurações de resina composta classe II, utilizando um aparelho à base de lâmpada halógena (QTH), e dois à base de LEDs. Cavidades padronizadas foram executadas nas faces proximais de 18 terceiros molares humanos. Resina composta Filtek P60 (3MESPE) foi inserida por meio de uma ponta fotocondensadora e fotoativada usando três sistemas de fotoativação: GI-Optilux401(QTH); GII-ColtoluxLED(LEDs) e GIII-UltraLumeLED5 (LEDs). Após o acabamento os dentes foram submetidos à ciclagem térmica à 5oC+2oC e 55oC+2oC, realizando um total de 500 ciclos. Os dentes foram seccionados no sentido vestíbulo-lingual e depois no centro das restaurações. A extensão da fenda foi observada sob MEV com um aumento de 1000X. Os dados foram analisados através do teste não paramétrico de Kruskal-Wallis. Os valores médios da amplitude das microfendas foram: GI 3.28+3.34 m; GII 1.48+1.89 m e GIII 3.11+3.45 m. Concluiu-se que fendas marginais foram observadas em todos os grupos; e entre os aparelhos de fotoativação utilizados neste estudo não houve diferenças estatísticas significantes, apesar de uma tendência de melhor desempenho para o GII
    corecore