16 research outputs found

    Calibration of the AKARI Far-Infrared Imaging Fourier Transform Spectrometer

    Full text link
    The Far-Infrared Surveyor (FIS) onboard the AKARI satellite has a spectroscopic capability provided by a Fourier transform spectrometer (FIS-FTS). FIS-FTS is the first space-borne imaging FTS dedicated to far-infrared astronomical observations. We describe the calibration process of the FIS-FTS and discuss its accuracy and reliability. The calibration is based on the observational data of bright astronomical sources as well as two instrumental sources. We have compared the FIS-FTS spectra with the spectra obtained from the Long Wavelength Spectrometer (LWS) of the Infrared Space Observatory (ISO) having a similar spectral coverage. The present calibration method accurately reproduces the spectra of several solar system objects having a reliable spectral model. Under this condition the relative uncertainty of the calibration of the continuum is estimated to be ±\pm 15% for SW, ±\pm 10% for 70-85 cm^(-1) of LW, and ±\pm 20% for 60-70 cm^(-1) of LW; and the absolute uncertainty is estimated to be +35/-55% for SW, +35/-55% for 70-85 cm^(-1) of LW, and +40/-60% for 60-70 cm^(-1) of LW. These values are confirmed by comparison with theoretical models and previous observations by the ISO/LWS.Comment: 22 pages, 10 figure

    Development and validation of a cryogenic far-infrared diffraction grating spectrometer used to post-disperse the output from a Fourier transform spectrometer

    Get PDF
    Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting diffraction gratings, which post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This paper discusses the development of a cryogenic (4 K) diffraction grating spectrometer that operates over the wavelength range of 285 to 500 μm and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance

    Performance of a cryogenic test facility for 4 K interferometer delay line investigations

    Get PDF
    The next generation of space-borne instruments for far infrared astronomical spectroscopy will utilize large diameter, cryogenically cooled telescopes in order to achieve unprecedented sensitivities. Low background, ground-based cryogenic facilities are required for the cryogenic testing of materials, components and subsystems. The University of Lethbridge Test Facility Cryostat (TFC) is a large volume, closed cycle, 4 K cryogenic facility, developed for this purpose. This paper discusses the design and performance of the facility and associated metrology instrumentation, both internal and external to the TFC. Additionally, an apparatus for measuring the thermal and mechanical properties of carbon-fiber-reinforced polymers is presented

    In-orbit performance of the Herschel/SPIRE imaging Fourier transform spectrometer: lessons learned

    Get PDF
    The Spectral and Photometric Imaging Receiver (SPIRE) is one of three scientific instruments on board the European Space Agency's Herschel Space Observatory which ended its operational phase on 29 April 2013. The low to medium resolution spectroscopic capability of SPIRE is provided by an imaging Fourier transform spectrometer (iFTS) of the Mach-Zehnder configuration. With their high throughput, broad spectral coverage, and variable resolution, coupled with their well-defined instrumental line shape and intrinsic wavelength and intensity calibration, iFTS are becoming increasingly common in far-infrared space astronomy missions. The performance of the SPIRE imaging spectrometer will be reviewed and example results presented. The lessons learned from the measured performance of the spectrometer as they apply to future missions will be discussed

    Herschel/SPIRE Imaging Fourier Transform Spectrometer

    No full text
    ABSTRACT We present the conceptual design of an imaging Fourier transform spectrometer (IFTS) for use with SCUBA-2, the second generation, wide-field, submillimetre camera currently under development for the James Clerk Maxwell Telescope (JCMT). This system, which is planned for operation in 2006, will provide simultaneous, broadband, intermediate spectral resolution imaging across both the 850 and 450 µm bands. The spectrometer will offer variable resolution with resolving powers ranging from R ~10 to 5000. When operated at low resolution, the IFTS will provide continuum measurements, well suited to spectral index mapping of molecular clouds, as well as bright nearby galaxies. The IFTS uses a folded Mach-Zehnder configuration and novel intensity beamdividers. The preliminary design, projected telescope performance and scientific impact of the IFTS are discussed. The preliminary design, novel observing modes, projected telescope performance and scientific impact of the IFTS are discussed

    Enhanced transmission and beam confinement using bullseye plasmonic lenses at THz frequencies

    No full text
    A major limitation in terahertz (THz) imaging applications is the relatively poor diffraction limited spatial resolution. A common approach to achieve subwavelength resolution is near-field imaging using a subwavelength aperture, but the low transmission efficiency through the aperture limits the sensitivity of this method. Bullseye structures, consisting of a single subwavelength circular aperture surrounded by concentric periodic corrugations, have been shown to enhance transmission through subwavelength apertures. At optical wavelengths, the fabrication of bullseye structures has been traditionally achieved by lithographic or chemical processes. Since the scale of plasmonic structures depends on the incident wavelength, precision micromilling techniques are well suited for THz applications. In this paper we describe a diamond micromilling process for the fabrication a plasmonic lenses operating at 325 GHz. Theoretical simulations are obtained using an FDTD solver and the performance of the lens is measured using a customized THz test bed.Peer reviewed: YesNRC publication: Ye

    Enhanced terahertz transmission through bullseye plasmonics lenses fabricated using micromilling techniques

    No full text
    Imaging applications at terahertz frequencies are, in general, limited to relatively low spatial resolution due to the effects of diffraction. By using a subwavelength aperture in the near-field, however, it is possible to achieve subwavelength resolution, although low transmission through the aperture limits the sensitivity of this approach. Plasmonic lenses in the form of bullseye structures, which consist of a circular subwavelength aperture surrounded by concentric periodic corrugations, have demonstrated enhanced transmission, thereby increasing the utility of near-field imaging configurations. In this paper, the design, fabrication, and experimental performance of plasmonic lenses optimized for 300 GHz are discussed. While nanofabrication techniques are required for optical applications, microfabrication techniques are sufficient for terahertz applications. The process flow for fabricating a double-sided bullseye structure using a precision micromilling technique is described. Transmission and beam profile measurements using a customized terahertz testbed are presented.Peer reviewed: YesNRC publication: Ye

    Enhanced terahertz transmission through bullseye plasmonics lenses fabricated using micromilling techniques

    Get PDF
    Imaging applications at terahertz frequencies are, in general, limited to relatively low spatial resolution due to the effects of diffraction. By using a subwavelength aperture in the near-field, however, it is possible to achieve subwavelength resolution, although low transmission through the aperture limits the sensitivity of this approach. Plasmonic lenses in the form of bullseye structures, which consist of a circular subwavelength aperture surrounded by concentric periodic corrugations, have demonstrated enhanced transmission, thereby increasing the utility of near-field imaging configurations. In this paper, the design, fabrication, and experimental performance of plasmonic lenses optimized for 300 GHz are discussed. While nanofabrication techniques are required for optical applications, microfabrication techniques are sufficient for terahertz applications. The process flow for fabricating a double-sided bullseye structure using a precision micromilling technique is described. Transmission and beam profile measurements using a customized terahertz testbed are presented.Peer reviewed: YesNRC publication: Ye

    Remotely Operated Infrared Radiometer for the Measurement of Atmospheric Water Vapour

    No full text
    ABSTRACT Astronomical arrays operating at (sub)millimeter wavelengths are seriously compromised by rapid variations in atmospheric water vapor that distort the phase coherence of incoming celestial signals. The signal received by each antenna of the array suffers a phase delay that varies rapidly with time and from antenna to antenna. Unless corrected, these distortions limit the coherence time of the array and seriously compromise its sensitivity and image quality. Building on the success of a prototype infrared radiometer for millimeter astronomy (IRMA), which operates in the 20µ
    corecore